Table 1 Overview of predictions from the analytical model
Atmosphere | No. of cycles | Shielding factor | Predicted mass loss (mg) | ||
---|---|---|---|---|---|
Fe | Cr | Ni | |||
Vacuum | 3 | - | 3.14 | 3.63 | 0.33 |
Helium | 25 | \(\frac{1}{171}\) | 0.17 | 0.20 | 0.01 |
Argon | 26 | \(\frac{1}{427}\) | 0.40 | 0.45 | 0.04 |
Total | 54 | - | 3.72 | 4.29 | 0.39 |