Abstract
Evaporation control is a critical facility resource during solidification experiments that limits processing time and must be tracked to ensure facility health. A thermodynamic analysis was performed on a ternary FeCrNi sample processed onboard the International Space Station (ISS) using ESA Electromagnetic Levitation (EML) facility in a microgravity environment. A non-ideal solution-based mathematical model was applied for the overall sample mass loss prediction during this study. The overall sample mass loss prediction is consistent with the post-flight mass loss measurements. The species-specific findings from this study were validated using post-mission SEM-EDX surface evaluations by three different facilities. The bulk composition prediction was validated using SEM-EDX and wet chemical analysis. The non-ideal solution model was then applied to predict the composition of the dust generated during EML testing. The thicknesses of the deposited layer on the EML coil at various locations were also calculated using the geometry of the facility and results were validated with near-real-time dust layer predictions from toxicity tracking software developed by the German Space Center (DLR) Microgravity User Support Center (MUSC).
Similar content being viewed by others
Introduction
Design optimization of additive manufacturing1 greatly depends on the control of unwanted evaporation and the knowledge of potential changes in concentration of alloying elements. Dynamic tracking of these quantities is crucial to support modeling and simulation of these processes2,3,4. The generation of aerosol dust through evaporation is an inherent aspect of steel smelting5,6. This dust may be comprised of minuscule particles that may be toxic to humans thus making it imperative to minimize dust production for the sake of resource conservation, safeguarding facility health, and ensuring operator safety. During space testing, monitoring dynamic mass loss is essential not only for maintaining a deposition below the specific astronaut toxicological exposure safety limits but also to ensure an accurate and precise measurements of the thermophysical properties of the material such as density, thermal expansion coefficient, viscosity and surface tension7,8.
Vaporization kinetic models based on Langmuir’s equation have been widely applied in modeling various material processing methods9,10,11. Butorina12 used a mathematical model to prove that the dominant mechanism of dust generation above a metal melt is evaporation compared to the dispersion in the absence of any active combustion of carbon from the melt with oxygen injection. This work also predicted the rate of dust formation and particle size using an electric furnace with no prediction of the species-specific composition of the generated dust after condensation. In the present work, the species-specific mass loss due to evaporation was predicted by using a non-ideal solution-based Langmuir model which was validated by both surface and bulk analysis. The prediction of the generated dust was also confirmed by doing a surface analysis of the sample holder during this study.
Previous thermodynamic assessment using an ideal solution model based on Langmuir’s equation was developed13 with limited success to predict the rate of evaporation for multi-element alloys processed using NASA Marshall Space Flight Center (MSFC)’s ground-based Electrostatic levitation (ESL) facility under vacuum conditions and ESA International Space Station (ISS) Electromagnetic Levitation (EML) facility. This model was later modified to consider non-ideal activity of individual alloy constituents and was successfully implemented to predict mass loss due to evaporation for two Ni-based superalloys CMSX-10 and MC2 using ISS-EML14 under Argon (Ar) gas atmosphere; Ni-based CMSX-4 Plus® (SLS) using ground-based MSFC ESL under vacuum condition and Japanese Aerospace Agency’s space-based ISS-ELF (Electrostatic Levitation Furnace) facility15 under Ar atmosphere. In this study, the non-ideal solution-based model was extended to predict volatile mass loss and dust generated during testing of ternary Fe-Cr-Ni stainless steel alloys conducted as a part of a series of Batch-1 ISS-EML experiments16,17.
A typical EML test is conducted either under 2.35 ± 0.17 × 10−7 mbar high-vacuum condition or under an inert shielding gas atmosphere 356 ± 2 mbar to limit evaporation. At low pressures, evaporation of atoms from the heated sample surface form aerosol particles which may agglomerate over time inside the processing chamber. The aerosols can form a fluffy layered structure on exposed surfaces such as the inner coil of EML facility and the sample cage holder as shown in Fig. 1. These structures were investigated during this study to determine the elemental composition of the deposit generated. In a gas environment, the evaporation flux is reduced near the droplet surface because of the presence of any adjacent molecules; this is called the vapor-shielding effect. This can be achieved by the use of an inert gas which significantly decreases the evaporation rate compared to vacuum. This phenomenon is modeled using a shielding factor which represents the percentage reduction in flux into inert gas as compared to the flux if the inert gas was not present – as is the case for vacuum testing18.
The purpose of this paper is to provide an opportunity to validate the analytical prediction of the deposit generated due to evaporation to measurements conducted during surface analysis of the sample holder. This study explores four methods to check the model: (1) total bulk mass loss, (2) species-specific mass loss, (3) bulk concentration shift, and (4) evaporation deposit composition prediction. In order to validate the analytical model, all four methods need to agree. Total bulk mass loss prediction was validated using post-processing sample mass, species-specific mass loss was validated using surface analysis using Scanning Electron Microscopy (SEM), bulk concentration shift was determined from the SEM analysis on both sample surface and in the bulk, and evaporation deposit composition prediction validated using the SEM on the sample surface holder. The dust deposition was calculated using facility geometry and validated using “Tox Tracker” software by the German Space Center (DLR) Microgravity User Support Center (MUSC) which monitors real time toxicity level due to dust generation during an EML test.
Results and discussion
A total of 54 melt cycles were performed for a FeCr21Ni19 (at.%) sample during Batch-1 processing of ISS-EML: 3 cycles in vacuum, 25 melt cycles in Helium (He) gas, and 26 melt cycles in Argon (Ar) gas atmosphere. The results from the mathematical modeling are as follows:
Estimation of mass loss due to evaporation
The chemical activity for the three individual alloying elements (Fe, Cr, and Ni) were calculated using the Thermo-Calc for temperature ranges corresponding to solid, liquid, and mushy zone mixture. This software calculates the thermodynamic properties of complex chemical systems from databases containing the free enthalpy functions of all phases: solids, liquids and gases. These databases, many of which are available as open science, are developed from experimental data and atomistic calculations. The chemical activities for this study were calculated using the Thermo-Calc TCFE8 database which are derived from the free enthalpy of the system and are established by minimizing the overall energy of the phases at equilibrium. Activity coefficients were then calculated to account for the non-ideal solution behavior of the steel ternary analog alloy as shown in Fig. 2a. Both Cr and Fe exhibit ideal solution behavior above 1900 K. Activity coefficient of Ni is slightly lower than that of the other elements. Non-ideal solution vapor pressures for each element were calculated using the activity coefficients and vapor pressure literature data from Alcock19. Cr has the highest vapor pressure and Ni has the lowest vapor pressure in this alloy system as shown in Fig. 2b. This indicates that Cr is more prone to evaporation compared to Fe and Ni during the superheating phase.
Based on the knowledge of activity-corrected vapor pressure, the evaporation model was applied for a discreet time interval of 0.01 s for each constituent throughout the 54 thermal cycles in the order of experiment sequence as set by the facility pyrometer data acquisition rate. Table 1 shows the applied average shielding factors used for the model and relevant mass loss prediction from the non-ideal solution model for different atmospheres in chronological order. A majority of the mass is predicted to be lost within the first 3 cycles run in vacuum condition without any gas shielding present. Application of Argon and Helium gases significantly reduced the mass loss prediction per cycle with an average of 0.03 mg in Argon and 0.02 mg in Helium atmosphere. The total mass loss predicted by the analytical model is 8.41 mg. The vapor pressures used for these measurements have an accuracy of ±5% as reported by Alcock19. The density has a reported accuracy of ±15%20. The one color high-precision pyrometer used for the temperature detection has an accuracy of ±5 K (resolution of <0.1 K above 873 K)14. Fromm18 reports an uncertainty of about a factor of three on the shielding factor reported in Table 1. Other sources of error include the computational error in quantifying the element-specific activity coefficients which is hard to establish due to numerous phase diagram data and thermodynamic quantities used to optimize the alloy system. Given the uncertainties present in the modeling parameter, the precited mass loss is in excellent agreement with the actual mass loss.
Compositional elemental analysis
The result from the analytical prediction was validated using the post-processed bulk and surface analysis using SEM-Energy Dispersive X-ray (EDX) Spectroscopy and Wet chemical analysis using Direct Current Plasma Emission Spectroscopy (DCPES) as listed in Table 2. An unpaired t-test was conducted for all three elements between three facility surface results which concludes that the datasets are not statistically different (p > 0.05). It is significant that the post processing measurements at independent laboratories agree. These results also indicate an enrichment of Cr on the surface. This is unexpected as Cr is the most volatile species and we would expect its concentration to be decreased following processing. The anticipated decrease is predicted accurately during modeling and validated using the post-processing analytical evaluation. Post-test wet chemical analyses of the bulk sample from Table 2 shows that Fe and Cr are depleted by 2.2% and 0.3% respectively and Ni is enriched by 7.2%. Based on p values observed from a two-tailed unpaired t test, it is concluded that the surface segregation is statistically significant for all elements (p < 0.05) as shown in Table 3. Hence, the analytical predictions were calculated by accounting for surface segregation which was less than 0.1% as compared to assuming bulk concentration. For all three constituents, analytical predictions are within 10% of the composition observed from the EDX analysis at Uni-Ulm and at Empa and within 2.6% of the wet chemical DCPES analysis.
Deposited layer composition-SEM evaluation
SEM-EDX evaluation of the sample surface and ISS-EML sample holder cage were performed at DLR as shown in Fig. 3. Figure 3a shows SEM images of an impact region where the sample collided with the pedestal along with a fragment shown in Fig. 3b which was detached from the cage wires. The SEM results conducted within these regions are listed in Table 4 along with the predicted deposit composition from the analytical model. The predicted composition for Ni from the non-ideal solution model is in good agreement with the SEM-EDX observation. As expected, the deposition layer is significantly enriched in the more volatile Cr and significantly depleted in Ni.
Deposited layer thickness - cage geometry
The ideal layer thickness during the EML testing can be measured based on the assumption of a spherical shell located at a known distance from the center of the sample. The total loss of mass is 8.9 mg which is known from the pre-test and post-test mass measurements. Assuming the deposited layer is 100% dense, using room temperature density, this mass corresponds to a volume of 1.128 mm3. The deposited layer thickness can be estimated at any radius and these predictions are listed in Table 5 for key facility locations where deposit may accumulate.
The approximate layer thickness can be estimated using Fig. 3 as the layer edges are clearly evident in conjunction with the associated micrograph scale. The observed layer thickness is in the order of 1140 nm with unknown layer density. The mass loss prediction for coil deposition at 100% packing density is 918 nm which shows excellent agreement with the prediction of 1032 nm from the MUSC Tox Tracker tool.
Methods
Materials
A FeCr21Ni19 (at.%) sample with a pre-test mass of 1.1509 g and an average diameter of 6.456 ± 0.050 mm was tested in microgravity during this study. This sample was made from high purity Fe, Cr and Ni using a suction mold technique in a water-cooled copper mold attached to an arc melter at Ulm University. The post-test sample mass was 1.142 g with a total mass loss of 8.9 mg. Key material properties used for the mathematical modeling are listed in Table 6.
Experimental facility
The experiments for this study were conducted using the ESA ISS-EML facility21,22 developed by Airbus Defense and Space23,24. This powerful containerless technique simultaneously allows researchers to levitate and thermally condition molten metal droplets providing the advantage of processing samples without adverse impacts related to sedimentation, chemical reactions, or heterogeneous nucleation on crucible walls. The extended period of microgravity environment also enables the opportunity to conduct long duration experiments in the undercooled regime under a wide range of controlled flow conditions25,26,27. A typical thermal profile from this facility during FeCrNi experimentation is shown in Fig. 4. The black line represents the temperature profile with time as measured by a pyrometer with an acquisition rate of 100 Hz. The red line represents the heater control voltage setting that is used to control cooling rate and internal convection within the sample. Note that in the cycle shown in Fig. 4, during the cooling phase from (242 to 250) s a heater control voltage setting was applied to intentionally induce internal convection to investigate the influence of stirring on solidification behavior. Additionally, a heater pulse was applied at around a time of 246 s to excite surface oscillations to conduct thermophysical property evaluations in the undercooled state.
Metallographic facilities
Post-test compositional surface analysis of the spherical sample was conducted in three different experimental facilities. The first set of analyses was conducted at Ulm University, Ulm, Germany using a Zeiss Leo 1550FE equipped with an EDX spectrometer from Oxford Instruments. Special care was taken to perform the measurement on a small area on the top of the sphere, in order to avoid possible systematic measurement errors due to the curvature of the surface.
The second set of analyses was conducted at the Center for X-ray Analytics, Empa Materials Science and Technology, Dübendorf, Switzerland. 2D X-ray diffraction analysis (2D-WAXD; STOE IPDS-II, 0.71073 Mo Kα radiation source) was carried out at the sample surface to confirm the cubic structure of the FeCrNi alloy with the space group Fm-3m and a = 3.56 Å. EDX was conducted at different positions of the sphere surface. Minor C and Al contamination was present on the sphere surface and was not been considered in the quantitative analysis. A Zeiss Gemini SEM 460 was used for high-resolution imaging and high-efficiency analytics, namely elemental analysis using an Oxford EDS system (Ulitm Max 170).
The third set of analyses was conducted at the Institut für Materialphysik im Weltraum, Deutsches Zentrum für Luft- und Raumfahrt (DLR) in Köln, Germany using an Zeiss SEM LEO 1530 VP. The EDX-detector is a liquid nitrogen-cooled Si(Li) detector operated under INCA software by Oxford Instruments. This facility was used to conduct surface analysis on the post-processed sample and the sample cage as well as the impact wire chip.
Direct Current Plasma Emission Spectroscopy (DCPES)- ASTM D4190, E1097 was conducted by Luvak Inc, Boylston, MA, USA for wet chemical analysis using a Beckman SpectraSpan IV. The sample was first dissolved in an acid mixture and then analyzed using the DCPES. Argon plasma provided the energy to temporarily excite electrons to the elements’ outer shells. The electrons return to their original shells emitting energy as light at specific wavelengths. Photomultiplier tubes detect the emission intensities at the specified wavelengths for comparison to the emissions of calibration standards created from certified reference materials. Solution standards with known concentrations of the elements to be analyzed were used to establish calibration data for each analysis. Calibration was verified through analysis of certified reference materials. The instrument precision for this method is ~2%.
Evaporation analysis—analytical approach
Analytical mass loss prediction for the FeCrNi system was performed on a model previously developed by the author13,14,15 based on Langmuir’s equation28. The total mass loss (\(v\)) from a surface of an alloy due to evaporation can be measured using:where \(R\) is the gas constant, \(A\) is the sample surface area and \(\alpha\) is correction factor. For each relevant species i, c is surface concentration, \(\gamma\) is activity coefficient, \({P}_{v}\) is vapor pressure and \(M\) is molecular weight at a given instantaneous temperature (\(T\)) for a discreet time interval \(\triangle t\). Temperature (\(T\)) was obtained from the pyrometer measurements (\({T}_{P}\)) during each test which was corrected using the liquids temperature (\({T}_{L}\)) and observed liquidus temperature (\({T}_{{PL}})\) for any emissivity shift due to oxidation29 using:
The changes in surface area were dynamically monitored through edge detection30. Vapor pressure, \({P}_{v,i}\) was calculated using the four-termed polynomial expression based on experimental measurements as cataloged by Alcock19:
Correction factor \(\alpha\) represents the shielding factor which is also known as the deviation in the rate of mass evaporation in an inert gas environment from the ideal evaporation in a vacuum environment (\(v/{v}_{0}\)). This shielding factor was applied to the metal evaporation rate which were previously determined by Fromm18 using:
where, \({v}_{0}\) is the mass loss in vacuum, \({P}_{G}\) is inert gas pressure, \(K\) and \(n\) are two empirical constants. For both Ar and He inert gases, \(K\) = 0.012 and \(n=1.0\) were used as provided by Fromm18. For a vacuum environment, \({P}_{G}=0\) such that evaluation of Eq. 4 results in no shielding. Shielding effect with He is less effective than Ar and \(\alpha\) for He gas atmospheres was measured using:
Under an Argon gas atmosphere of 350 millibar, the shielding factor becomes \({\alpha}=\) 1/427 while under Helium gas atmosphere the shielding factor is corrected to a value of \(\alpha =\)1/17 1 using Eq. 5.
This non-ideal solution approach emphasizes thermodynamic prediction of non-ideal solution behavior of each species in solution in conjunction with empirical predictions of the variation of vapor pressure with temperature. It does not address validation of ground-based experimental test results but rather emphasizes tracking of dynamic composition shifts for volatile species.
Evaporation analysis—empirical approach using MUSC Tox Tracker
The results from non-ideal solution were validated using the Tox Tracker by DLR-MUSC. This is a software-based simulation tool primarily used for ISS-EML experiment analysis. After each space experiment, the Tox Tracker tool is used to track facility health—the potential for deposited material on the coil—and the accumulation of specific toxic species—to ensure astronaut safety—based on global evaporation from the sample as a function of the sample thermal profile. Ground-based global mass evaporation is measured pre-mission and element specific losses are then predicted assuming that individual species exhibit ideal behavior in solution. The Tox Tracker uses the near-real time temperature data from the pyrometer after each melt cycle to calculate for each measured temperature value the evaporated mass. The total evaporated mass is distributed to each element assuming an ideal solution model using the initial concentration of the element weighed with the vapor pressure. The Tox Tracker evaluation is based on real temperature tracking, experimentally verified global evaporation, and extrapolation of results to specific chemical species. This approach does not take into account changes in concentration over time for specific species or non-ideal solution behavior but rather emphasizes prediction of overall mass loss based on experimental validation.
Data availability
Data are available upon request from the German Space Agency (DLR).
Code availability
Code for the mathematical model will be available upon request from the corresponding author.
References
Lü, L., Fuh, J., Wong, Y. S. Laser-Induced Materials and Processes for Rapid Prototyping (1st edn). https://doi.org/10.1007/978-1-4615-1469-5 (Springer Science & Business Media, 2001).
Ranaiefar, M. et al. A differential evaporation model to predict chemistry change of additively manufactured metals. Mater. Des. 213, 110328 (2022).
Collur, M. M., Paul, A. & Debroy, T. Mechanism of alloying element vaporization during laser welding. Met. Trans. B. 18B, 733–740 (1987).
Klapczynski, V. et al. Temperature and time dependence of manganese evaporation in liquid steels. Multiphysics modelling and experimental confrontation. Scr. Mater. 221, 114944 (2022).
Doromin, I. E. & Svyazhin, A. G. Experimental study of steel smelting dust component evaporation. Metallurgist 58, 866–871 (2015).
Svyazhin, A. G., Romanovich, D. A. & Rao, P. K. Dust formation during steel production and Fe-C melt evaporation. Metallurgist 60, 47–53 (2016).
Lee, J. & Matson, D. M. Prediction of mass evaporation of Fe50Co50 during measurements of thermophysical properties using an electrostatic levitator. Int. J. Thermophys. 35, 1697–1704 (2014).
Nawer, J. et al. Uncertainty analysis and performance evaluation of thermophysical property measurement of liquid Au in microgravity. Npj Microgravity 9, 38 (2023).
Nakao, R., Fukumoto, S., Fuji, M. & Takeguchi, H. Evaporation of alloying elements and behavior of degassing reactions of high chromium steel in electron beam melting. ISIJ Int. 32, 685–692 (1992).
Lei, Y. P., Murakawa, H., Shi, Y. W. & Li, X. Y. Numerical analysis of the competitive influence of Marangoni flow and evaporation on heat surface temperature and molten pool shape in laser surface remelting. Comput. Mater. Sci. 21, 276–290 (2001).
Mikhailov, A., Zubarev, K., Kotel’nikov, G. I., Semin, A. & Grigorovich, K. V. Vaporization of the components of Nickel alloys in a vacuum induction furnace. Izv. Vuz. Chern. Metall. 46, 35–38 (2016).
Butorina, I. V. & Fedotova, E. S. Role of evaporation in the formation of smelting dust. Steel Transl. 46, 447–452 (2016).
Nawer, J., Xiao, X., SanSoucie, M. P. & Matson, D. M. Effect of mass evaporation on measurement of liquid density of Ni-based superalloys using ground and space levitation techniques. High Temp. High Press. 49, 17–29 (2020).
Nawer, J., Gossé, S. & Matson, D. M. Tracking evaporation during levitation processing of nickel-based superalloys on the ISS. JOM 72, 3132–3139 (2020).
Nawer, J. et al. A quantitative comparison of thermophysical property measurement of CMSX-4® Plus (SLS) in microgravity and terrestrial environments. High Temp. High Press. 52, 323–339 (2023).
Matson, D. M. Retained free energy as a driving force for phase transformation during rapid solidification of stainless steel alloys in microgravity. Npj Microgravity 4, 22 (2018).
Hanlon, A., Matson, D. M. & Hyers, R. Microgravity experiments on the effect of internal flow on solidification of Fe-Cr-Ni stainless steels. Ann. N.Y. Acad. Sci. 1077, 33–48 (2006).
Fromm, E. Reduction of metal evaporation losses by inert gas atmospheres. Met. Trans. A 9A, 1835–1838 (1978).
Alcock, C. B., Itkin, V. P. & Horrigan, M. K. Vapour pressure equations for the metallic elements: 298–2500 K. Can. Metal. Q. 23, 309 (1984).
Matson, D. M., Xiao, X., Rodriguez, J. & Wunderlich, R. Preliminary experiments using electromagnetic levitation on the International Space Station. Int. J. Microgravity Sci. Appl. 33, 330206 (2016).
Xiao, X. Modeling of induced surface oscillation damping behavior in levitated molten metal droplets. Order No. 10621127 Tufts University, 2017. United States— Massachusetts: ProQuest. Web. 8 May 2024.
Lohoefer, G., Piller, J. The new ISS electromagnetic levitation facility - ‘MSL-EML’. In: Proceedings of the 40th AIAA Aerospace Sciences Meeting and Exhibit, Reston, VA. https://doi.org/10.2514/6.2002-764 (AIAA, 2022).
Seidel, A., Soellner, W. & Stenzel, C. EML—an electromagnetic levitator for the International Space Station. J. Phys. Conf. Ser. 327, 012057 (2011).
Seidel, A., Soellner, W. & Stenzel, C. Materials science investigations using electromagnetic levitation. J. Phys. Conf. Ser. 327, 012015 (2011).
Xiao, X., Brillo, J., Lee, J., Hyers, R. W. & Matson, D. M. Impact of convection on the damping of an oscillating droplet during viscosity measurement using the ISS-EML facility. Npj Microgravity 7, 36 (2021).
Baker, E., Nawer, J., Xiao, X. & Matson, D. M. MHD surrogate model for convection in electromagnetically levitated molten metal droplets processed using the ISS-EML facility. Npj Microgravity 6, 9 (2020).
Bracker, G. P. et al. The effect of flow regime on surface oscillations during electromagnetic levitation experiments. High Temp. High Press. 49, 49–60 (2020).
Langmuir, I. Vapor pressures, evaporation, condensation and adsorption. J. Am. Chem. Soc. 54, 2798–2832 (1932).
Tank, V. & Dietl, H. Multispectral infrared pyrometer for temperature measurement with automatic correction of the influence of emissivity. Infrared Phys. 30, 331 (1990).
Nawer, J. & Matson, D. M. Quantifying facility performance during thermophysical property measurement of liquid Zr using electrostatic levitation. High Temp. High Press. 52, 123–138 (2023).
Acknowledgements
This project was funded by NASA under grants NNX17AH41G, 80NSSC19K0256 and 80NSSC23K0573. The author also acknowledges support from the European Space Agency (ESA) and the German Space Agency (DLR) administration as this work was conducted under the collaborative framework of ThermoLab AO-2009-1020 and LIPHASE AO-2009-0894. The authors acknowledge collaborative support by team members from MUSC through access to the ISS-EML facility which is a joint undertaking of the European Space Agency ESA and the German Aerospace Administration DLR.
Author information
Authors and Affiliations
Contributions
J.N.: manuscript writing, methodology and data analysis; B.S.: DLR SEM analyses and manuscript revising; M.K.: DLR SEM analyses, funding acquisition and manuscript revising; S.G.: Thermocalc calculations and manuscript revising; R.W. sample preparation, experimentation and manuscript revising; M.M.: Uni-Ulm SEM analysis and manuscript revising; S.S.: experimentation, MUSC calculations and manuscript revising; A.B.: Empa EDX analysis and manuscript revising; A.N.: Empa EDX analysis and manuscript revising; D.M.M.: concept, experimentation, DLR SEM analyses, manuscript writing and funding acquisition.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests. D.M.M. is a member of the Editorial team for npj Microgravity and was not involved in the journal’s review of, or decisions related to this manuscript.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Nawer, J., Stanford, B., Kolbe, M. et al. Thermodynamic assessment of evaporation during molten steel testing onboard the International Space Station. npj Microgravity 10, 77 (2024). https://doi.org/10.1038/s41526-024-00416-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41526-024-00416-1