Fig. 6: Lower divertor gas valve system identification in Super-X divertor configuration. | Nature Energy

Fig. 6: Lower divertor gas valve system identification in Super-X divertor configuration.

From: Demonstration of Super-X divertor exhaust control for transient heat load management in compact fusion reactors

Fig. 6

a, Poloidal cross-section showing the EFIT++ magnetic equilibrium reconstruction (t = 0.55 s) with a conceptual illustration of the lower divertor Dalpha filterscope sightline, lower divertor valve location and lower divertor Fulcher band front position Ltar. b, Time domain (top) and frequency domain (bottom) response of the detrended lower divertor Fulcher band front position Ltar around the operating point. c, MWI Fulcher band inversion (t = 0.55 s), indicating highly detached conditions. d, Time domain (top) and frequency domain (bottom) response of the detrended lower divertor Dalpha filterscope (-) around the operating point to a perturbation of the requested lower D2 divertor gas valve flow rate (--). All data from experiment number 49297.