Main

Nuclear fusion has the potential to provide virtually limitless, inherently safe and clean energy1. The most mature configuration, the tokamak2, magnetically confines plasma particles in a torus-shaped device (Fig. 1a). However, the core power, carried by the plasma particles, eventually propagates outside the magnetically confined region and is compressed into a narrow region of open magnetic field lines, resulting in an immense heat flux3,4 akin to a welding torch. To prevent this heat flux from reaching the main chamber wall, it is diverted to a dedicated region (the divertor; Fig. 1a) using coils to create a magnetic field ‘null’. A key issue for reactor-scale devices is that the resulting divertor heat load far exceeds material limits if not mitigated3,4. As these loads are not only static but also change dynamically, the mitigation of transients is critical.

Fig. 1: The MAST-U tokamak, its divertor configurations and detachment.
figure 1

a, MAST-U vessel with the gas valve and MWI44 locations indicated, the transport of energetic core particles towards the outer divertor targets is indicated by the red arrows. b, Cross-section of the lower divertor, using radial (R) and vertical (Z) coordinates, showing the wall, magnetic coils and the magnetic equilibria of the Super-X, Elongated and Conventional divertor configurations. c, Schematic of an attached divertor (left) with volumetric impurity radiation and an ionization region located at the strikepoint (Ltar = 0), a detached (Ltar > 0) divertor (right) absorbs the incoming heat flux by forming a neutral cushion, massively reducing the strikepoint heat flux. Credit: background image in a, United Kingdom Atomic Energy Authority.

Compact, high magnetic field devices such as the Affordable Robust Compact reactor (ARC)5, Smallest Possible ARC (SPARC)6 and the Spherical Tokamak for Energy Production (STEP)7,8,9,10 promise a more cost-effective and faster route to commercial fusion energy11. However, the decreased volume per unit power results in a substantially increased heat and particle load per area, exacerbating the heat exhaust challenge12,13, which is already daunting for large devices such as ITER3 and the demonstration power plant (DEMO)4.

In a divertor, the plasma heat flux can be reduced by orders of magnitude by converting plasma energy flux (directed primarily along field lines) into photons and neutrals (not held by the magnetic field), spreading the heat flux over a larger area (Fig. 1c). This is achieved by injecting impurity and/or hydrogenic gases, dissipating the majority of the power (~75%) (refs. 14,15,16) in a ‘radiative region’ upstream of the ion source. The ion source initially remains attached at the target (Te > 3–5 eV), higher gas injection rates lead to a detached ion source (Te < 3–5 eV). This builds a cushion of neutral atoms and molecules above the strikepoint, enabling further power removal to ultimately ensure the required order-of-magnitude heat flux reduction.

Insufficient gas injection results in inadequate dissipation and, consequently, insufficient divertor protection. Conversely, excessive gas injection can drive the cold, detached, region into the core plasma, reducing core performance17,18,19 and potentially damaging the reactor through a violent plasma termination18. The challenge of maintaining this balance is exacerbated by transients originating from plasma core instabilities2, core pellet fuelling20 and power-sharing imbalances between divertor targets10,21. The resulting cyclic power loading can lead to a loss of stable detachment and therefore divertor tile cracking22. Active power exhaust control is thus imperative for reactor-scale devices to maintain the ‘right’ balance4,8,19,23,24 in both attached and detached conditions.

Recent progress in exhaust control has been achieved using conventional divertors, employing diagnostics based on impurity emissions location19,25, radiated power26,27,28,29, tile temperature30, plasma temperature31, ion target flux32 and tile current33. However, active control can only mitigate transients slow enough for gas actuators to respond, faster transients must be absorbed passively, an inherently limited capability. It therefore remains uncertain if conventional divertors can effectively manage the power exhaust challenge17,34, posing a major risk for fusion power reactors.

Several alternative exhaust solutions are being explored as a risk-mitigation strategy, including liquid metal divertor targets35, highly radiative plasma regimes36 and Alternative Divertor Configurations (ADCs)17,34. These configurations rely on plasma shaping to improve power exhaust, detachment access and its control17,34. Whereas ADCs are investigated as a risk-mitigation strategy for DEMO, they are an absolute necessity for compact reactors. However, ADCs increase engineering complexity, divertor volume and therefore cost (Methods)34,37. Any reactor implementation has to carefully consider the trade-off between these drawbacks and the attractive operating regimes ADCs offer.

One of the most promising ADCs is the Super-X Divertor (SXD) (Fig. 1a,b), featuring an increased strikepoint major radius, increasing the target area. Under steady-state conditions, massively reduced target heat and particle fluxes with an improved access to detachment have been observed14,15,16, consistent with reduced model predictions23 and simulations38,39.

The Mega Ampere Spherical Tokamak in the UK was recently upgraded (MAST-U)40,41 (Extended Data Fig. 1) to facilitate long-legged ADCs. It features a large divertor volume to explore various ADCs, including the SXD. Less extreme configurations such as the Elongated Divertor (ED) (Fig. 1b) can also be achieved and are potentially easier to integrate in a reactor (Fig. 8). The ADCs are uniquely integrated with strong baffling to reduce the escape of divertor neutrals towards the core38,42. It features an up/down symmetric double-null geometry for improved power distribution10,13,34,43.

In this work, we experimentally demonstrate real-time exhaust control in ADCs, employing the ED and SXD divertor configurations (Fig. 1b). This presents a drastically different situation compared to the single-null, conventional geometries employed previously19,25,26,27,28,29,30,31,32,33. Our experiments feature a double-null, strong baffling and a 2× increase in total magnetic flux expansion16. We directly control the ionization front location in real time, and thereby detachment state, by diagnosing D2 Fulcher emissions from excited molecules14,15,16. This work proves that ADCs are compatible with exhaust control systems, a requirement for their implementation in fusion power reactors. We also showcase their capability to passively absorb transients, a major advantage in addressing the heat exhaust problem. Our results also show that the upper and lower divertors are largely decoupled, suggesting that both divertors can be near independently controlled. This fulfils a crucial requirement for double-null reactor designs to compensate transients originating from power-sharing asymmetries10. The implications of the ADC benefits for power exhaust control are discussed and we demonstrate the scalability of our detachment sensor strategy to reactors on a scientific, conceptual level, focusing on STEP7,8,9,10. This pioneering experimental work presents major progress towards addressing a key challenge for realizing fusion energy.

Dynamics of ADCs

In our experimental results, we observe major advantages of ADCs for solving the fusion exhaust challenge.

First, the divertor dynamics are studied to investigate the capability of handling transients. We systematically identify the detachment input–output dynamics, as recently demonstrated for conventional divertors19,25. In these experiments, the divertor response to D2 gas inflow perturbations is measured to identify the dynamics. We employ a (low-field side) main chamber D2 gas valve, using a low-confinement mode (L-mode) scenario with 1.5-MW Neutral Beam Injection heating and core electron densities of 2–6 × 1019 (m3) (Methods). Using a novel ionization front-tracking technique, we perform a pioneering study of the detachment front dynamics in alternative divertor configurations in MAST-U.

The detachment state is tracked using the D2 Fulcher emissions front location, defined as the position with 50% intensity extinction from maximum, as a proxy for the ionization front15 using the lower divertor Multi-Wavelength-Imaging (MWI)44 camera system (Fig. 1a). In post-processing, the images are inverted45 to obtain a 2D emissivity distribution, allowing the distance between target and ionization front along the divertor leg to be quantified45 as Ltar (Fig. 1c) (Ltar > 0 during detachment; Methods). For comparison, we conduct conventional divertor (CD) experiments using an additional X-point camera system not available in the earlier ED and SXD experiments (Methods).

By analysing the frequency response of Ltar, the detachment front dynamics are retrieved. The perturbation signals are especially designed considering experimental constraints (Methods). The considered system includes the gas system dynamics, plasma response and MWI camera and is conceptually illustrated in Fig. 2. Because only the requested gas valve flow rate can be perturbed, the gas system dynamics cannot be separated from the detachment dynamics46 (Methods). A typical time and frequency domain response is shown in Fig. 2 (Extended Data Fig. 2). We observe that the response on non-excited frequencies mostly stays below the average noise level, with exceptions attributed to the gas system, not the plasma dynamics themselves (Methods). This indicates dominantly linear dynamics47. Crucially, this implies that standard, linear control techniques are also suitable for these ADCs, akin to conventional configurations19,25.

Fig. 2: System identification and the feedback-control loop.
figure 2

a, Time domain and frequency domain response of the D2 Fulcher band front position Ltar to a perturbation of the requested main chamber D2 gas valve flow rate in Super-X divertor geometry, experiment number 47116. The input frequency component is clearly observed in the system output; Extended Data Fig. 2. b, Feedback-control loop showing the reference front position Ltar,ref, the error e with respect to the measured front position Ltar and the corresponding requested flow rate u by the controller. The to-be-controlled system includes the gas system, plasma and MWI sensor dynamics.

Comparing the dynamical response of the three divertor configurations (Fig. 3) shows that the ED and SXD have a much greater capacity to passively absorb transients and feature a reduced detachment onset threshold. In contrast, the CD requires much higher flow rates (5 × 1021 D2 s−1) and line-averaged core densities (5 × 1019 m−3 vs 3 × 1019 m−3) to detach, whereas the ED and SXD are already detached at the lowest flow rate needed for stable core conditions (1 × 1021 D2 s−1) (Fig. 3a, showing Ltar > 0 for the ED and SXD). When the ionization front starts to detach from the strikepoint in the conventional divertor (Ltar > 0), it moves outside the divertor within 2.5 ms, to above the X point, resembling Multifaceted Asymmetric Radiation from the Edge48. This persists until the end of the experiment, even though the fuelling is subsequently reduced (Extended Data Fig. 3). The observed transition from attached to above the X point indicates a very narrow operational window, that is, only a very limited range of gas flow rates would position the front in between target and X point, leading to a much more pronounced response to fuelling perturbations.

Fig. 3: Comparison of Super-X, Elongated and Conventional divertor front movement.
figure 3

a, Divertor detachment state expressed as the distance of the Fulcher band front position to target along the divertor leg Ltar. b, D2 Fulcher front position as the Poloidal distance between the D2 Fulcher emission front and the X point Lx. c, Requested main chamber gas flow rate (left, --) and line-averaged core electron density (right, -). The requested gas flow rate is negative due to the inaccuracies in the gas valve calibration; Methods. d, Two-dimensional view of the magnetic configurations with an overlay of the front position at each timestamp within the time frame.

This is in stark contrast with both the SXD and ED divertors, where the response to the perturbations is only minimal (limited Ltar variation). The combination of this decreased sensitivity and increased divertor leg length entails that these ADCs have a much larger capacity to passively absorb transients and therefore avoid re-attachment and a radiative core plasma collapse. These findings are consistent with previous steady-state observations14,15,16 of a reduced detachment onset and front sensitivity for ADCs; our results now illustrate that these benefits extend to a dynamic situation.

As the ionization front in CD configuration is either attached or outside the divertor for most datapoints, only the dynamics for the ED and SXD configurations can be identified. The linear dynamics of the ED (*) and SXD () configurations around the operating point can be expressed as a frequency response function (FRF) by analysing the input–output ratio in frequency domain (Fig. 4). We use the local-polynomial method49 (LPM) to correct for transient effects and estimate 2σ error bars47 (Methods). Across all measurements, we observe a 40° to 70° phase delay in the considered 7.7–38.5-Hz frequency range, notably less then the reported 70° to 140° in core density response46. This suggests that the response can be modelled as a fractional differential equation, as observed for conventional divertors in the Tokamak à configuration variable (TCV)19,25. The SXD and ED divertor configurations show a similar phase response, however, the SXD magnitude response is smaller compared to the ED (Fig. 3 and 4), suggesting a potential additional reduction in front sensitivity for the SXD.

Fig. 4: Detachment front frequency response.
figure 4

Requested main chamber gas valve flow rate change to Fulcher band front position response δLtar in Elongated (*) and Super-X () configuration expressed as gain (top) and phase (bottom) ratio over frequency. Mean response value and 2σ error bars obtained using the LPM47,49 across three (#47080, #47086, #47118), four (#47083, #47116) and 13 periods (#47119). The fitted model represents a deliberate worst-case fit46, aimed at guaranteeing stability margins when used to design a feedback controller.

Source data

We also consider the response of the main chamber Dalpha filterscope (Extended Data Figs. 4 and 5), capturing neutral hydrogen Balmer-alpha emissions as a key measure of plasma-neutral interaction. It is the most direct measurement available for when the injected gas reaches the plasma as it directly views the gas inlet. As a 30° to 90° phase delay is observed, the gas system itself might be a dominant source of the observed dynamics, underling the importance of gas system dynamics for exhaust control. A complete understanding of the observed divertor dynamics is still lacking, requiring further investigation across multiple devices.

This marks experimental confirmation of the benefits of ADCs in passively handling dynamic transients, extending previous results for steady-state conditions23,38,39. In addition to demonstrating the benefits of ADCs for solving the exhaust challenge in fusion power reactors, our results also enable feedback exhaust control in MAST-U through the systematic design of an exhaust controller.

Feedback control

We will now demonstrate that ADCs are compatible with exhaust control, a requirement for their application in fusion power reactors4,19,23,24.

By matching a dynamic model to the measurements (Fig. 4), detachment control is enabled without explicitly modelling the intricacies of the underlying physical processes. We opt for a simple fractional order transfer function G(jω), with gain K = 10−22 (-), time constant τ = 0.3715 (s), time delay τd = 10−3 (s) and frequency ω (rad s−1),

$${\mathrm{G}}(j\omega )=\frac{{{K}}}{{(\tau j\omega )}^{0.7}+1}{e}^{-{\tau }_{{\rm{d}}}{\rm{j}}\omega}.$$
(1)

Using G(jω), we design a basic Proportional-Integral (PI) controller C(jω) through the loopshaping method50 as

$${\rm{C}}(j\omega )={{{K}}}_{{\rm{p}}}+\frac{{{{K}}}_{{\rm{i}}}}{j\omega },$$
(2)

with proportional and integral gains as Kp = 5 × 1022 and Ki = 3 × 1024, respectively. The controller is targeted towards robustness for this proof of concept demonstration, evidenced by the low closed-loop bandwidth of 9.5 Hz and high 70° phase margin50, indicating that future performance improvements are probably possible.

Feedback detachment control requires real-time inference of the ionization front position. An inversion-less tracking algorithm51, directly operating on raw camera images, is adopted for this real-time implementation. Although yielding comparable results to the inverted technique, its coordinate transformation51,52 introduces additional noise and limitiations (Extended Data Fig. 7, Methods).

Detachment control is successfully achieved using the same controller for both ED and SXD (Fig. 5): in both scenarios, the controller adeptly follows the reference trajectory. This illustrates the robustness of our detachment control implementation; the same approach is successful for two distinct divertor configurations. In contrast, achieving detachment control in CD configuration, for this specific scenario and fuelling location, would be virtually impossible as the front quickly moves from near the strikepoint to outside the divertor chamber and remains there. This happens within the 2.5-ms acquisition time of the MWI (Extended Data Fig. 3), too fast for the gas system to act upon.

Fig. 5: Feedback exhaust control in Elongated and Super-X divertor configuration in MAST-U.
figure 5

aj, The Elongated divertor in experiment number 47998 (ae) and the Super-X divertor in experiment number 48001 (fj). a,f, Fulcher-band-filtered MWI44 image with 3D model wireframe overlay (white lines). The green box indicates the region where the emissions front-tracking algorithm51 is active; the divertor leg pixels (orange dots) are detected through a 50% threshold on the maximum intensity (black circle) with the front position (red cross) taken as the divertor pixel nearest to the target. b,g, Front-tracking result transformed to the poloidal cross-section with the Equilibrium Fitting (EFIT++) magnetic equilibrium reconstruction (black) overlay, including flux contour lines (dashed). c,h, Time evolution of the poloidal distance-to-target Ltar and its applied reference. d,i, Time evolution of the D2 gas flow rate request by the controller. e,j, Time evolution of core line-integrated electron density.

When the controller aims to move the front towards the target, the gas flow is reduced, however the ionization front moves slower than requested (Fig. 5f–j). This is probably due to the high divertor neutral pressure given the present lack of cryopumping40 in MAST-U, illustrating the importance of adequate pumping for exhaust control, consistent with the impurity retention issues noted in TCV25.

We have demonstrated exhaust control in ADCs. Crucially, this now proves their compatibility with exhaust control as required for (compact) fusion power reactors. A key requirement for double-null power reactor designs is independent exhaust control of the lower/upper divertors to combat the expected asymmetric transients from divertor power-sharing imbalances8,10. Therefore, we investigate the coupling between the upper and lower divertors in the next section.

Upper–lower divertor coupling

Thus far, open divertor geometries have exhibited a clear coupling between upper and lower divertors53. Here we systematically investigate this coupling for the strongly baffled divertor chambers in MAST-U, demonstrating the key benefits of ADCs for enabling independent control of the divertor regions.

As opposed to perturbing core fuelling, individual system identification perturbations using upper and lower divertor gas valves are performed. When perturbing only the lower divertor D2 gas valve, a clear response is observed in both the lower divertor ionization front position Ltar and lower divertor Dalpha filterscope (Fig. 6). Conversely, the upper Dalpha filterscope indicates no response to this perturbation (Extended Data Fig. 6).

Fig. 6: Lower divertor gas valve system identification in Super-X divertor configuration.
figure 6

a, Poloidal cross-section showing the EFIT++ magnetic equilibrium reconstruction (t = 0.55 s) with a conceptual illustration of the lower divertor Dalpha filterscope sightline, lower divertor valve location and lower divertor Fulcher band front position Ltar. b, Time domain (top) and frequency domain (bottom) response of the detrended lower divertor Fulcher band front position Ltar around the operating point. c, MWI Fulcher band inversion (t = 0.55 s), indicating highly detached conditions. d, Time domain (top) and frequency domain (bottom) response of the detrended lower divertor Dalpha filterscope (-) around the operating point to a perturbation of the requested lower D2 divertor gas valve flow rate (--). All data from experiment number 49297.

Subsequently, only the upper divertor valve is perturbed (Fig. 7). Whereas we observe a clear response in the upper Dalpha filterscope intensity, no response in the lower divertor ionization front position nor Dalpha intensity is observed. Additionally, the lower divertor is substantially less deeply detached than during the lower divertor perturbation (Fig. 6). This disparity suggests a limited influence of the upper divertor perturbation on the lower divertor state, demonstrating a clear decoupling between the two divertors. This is a major result, confirming preliminary, static observations14.

Fig. 7: Upper divertor gas valve system identification in Super-X divertor configuration.
figure 7

a, Poloidal cross-section showing the EFIT++ magnetic equilibrium reconstruction (t = 0.55 s) with a conceptual illustration of the upper divertor Dalpha filterscope sightline, upper divertor valve location and lower divertor Fulcher band front position Ltar. b, Time domain (top) and frequency domain (bottom) response of the detrended lower divertor Fulcher band front position Ltar around the operating point. c, MWI Fulcher band inversion (t = 0.55 s), indicating highly detached conditions. d, Time domain (top) and frequency domain (bottom) response of the detrended upper divertor Dalpha filterscope (-) around the operating point to a perturbation of the requested upper D2 divertor gas valve flow rate (--). All data from experiment number 49298.

Preliminary He seeding experiments have indicated that He injected in the lower divertor does spread rapidly to the core and upper divertor, potentially limiting the observed decoupling to neutral pressure only, prompting further study. We attribute the observed decoupling for D2 to the strong neutral baffling of the divertor chamber as such decoupling is absent in open divertor geometries53.

Our findings prove that instabilities driven by interaction between the upper and lower divertor controllers are highly unlikely using D2 actuation. The required independent control of both divertor regions can therefore likely be achieved, crucial for ADC deployment in fusion power reactors.

Discussion

In this work, we have demonstrated key benefits of ADCs for exhaust control: (1) a highly reduced sensitivity to perturbations that enables active exhaust control in otherwise unfeasible situations and facilitates (2) a major increase in the ability to passively absorb fast transients, which would otherwise damage the divertor; furthermore, (3) a strong isolation of each divertor from other reactor regions enables near-independent control of the divertors and core plasma. These benefits illustrate how ADCs are extremely beneficial for exhaust control, forming a viable risk-mitigation strategy for power exhaust handling in fusion reactors.

A practical application of ADCs is STEP, targeting completion in the 2040s and ultimately aiming to deliver power to the UK grid7,8,9,10. The compact reactor features tightly baffled long-legged divertors, with an increased strikepoint radius in a double-null configuration (Fig. 8a and Extended Data Fig. 8), strongly resembling the MAST-U set-up.

Fig. 8: Conceptual STEP divertor detachment sensor.
figure 8

a, Artistic impression of the STEP reactor7,8,9,10, with the lower divertor region indicated by the red box. b, Divertor ionization rate in an early design of STEP for a deeply detached Scrape-Off Layer Plasma Simulation (SOLPS)-ITER10 with overlayed synthetic spectroscopy viewing geometry and detected detachment front. c, Divertor D2 pressure, with overlayed detected detachment front. d, Synthetic D2 Fulcher band spectroscopy signals, using Fulcher emissions profiles generated by post-processing39, for the sightlines shown in b, indicating the correlation to the ‘true’ ionization source from the simulation and subsequent detection of the detachment front. a.u., arbitrary units. Credit: a, UK Industrial Fusion Solutions.

Beyond illustrating the capabilities of ADCs to mitigate key risks in reactors, our research also has practical implications for reactor detachment control. Monitoring the detached regime is generally complex, requiring detailed analysis techniques that are challenging to be applied in real time14,15,54. This work enables real-time detachment diagnosis, using D2 Fulcher band emissions as a direct indicator for the detachment front location.

We demonstrate the scientific feasibility of this sensor technique by post-processing39 STEP SOLPS-ITER simulations10 to generate D2 Fulcher emissions profiles and subsequently produce synthetic brightness signals (Fig. 8d). As opposed to using imaging systems, our sensor technique can even work with this synthetic spectroscopy set-up with a limited, fictitious, viewing geometry (Fig. 8b). Such an implementation can be shielded from the harsh reactor environment55 and is thus more reactor relevant. The simulation shows a highly detached lower divertor as a result of a power-sharing imbalance, originating from an upward shift in the plasma equilibrium towards an upper single null10. With most power flowing to the upper divertor, the lower divertor ionization front moves upstream (Fig. 8c). Such power-sharing imbalances are a key challenge in STEP8,10, our results show how this can be diagnosed by tracking the D2 Fulcher emissions profile in the lower divertor, demonstrating the scientific feasibility of the highlighted sensor technique in reactors. Consequently, it is well suited to play a central role in the diagnostic set, which includes measurements targeting the attached regime, to fully diagnose the divertor for exhaust control.

The ultimate goal of an exhaust control system is to maintain acceptable exhaust conditions in the presence of disturbances, requiring: (1) divertor diagnosis, (2) passive transient absorption and (3) independent control of both divertors. Our pioneering MAST-U results show great promise in these aspects. Independent, simultaneous control of the lower/upper divertors is a major milestone planned to be demonstrated in the 2024–2025 MAST-U physics campaign. Higher external heating levels (>10 MW) are planned from 2026, enabling experimental validation at more reactor-relevant powers and studies employing a blend of hydrogenic and impurity gasses as required for power exhaust control in reactors8,24.

To conclude, we have demonstrated that alternative divertors are compatible with exhaust control, as required for fusion power reactors. We highlighted major benefits for exhaust control, confirming alternative divertors as a viable risk-mitigation strategy towards manageable heat loads in (compact) fusion reactors.

Methods

MAST-U fusion experiment

The Mega Ampere Spherical Tokamak-Upgrade (MAST-U) is a tokamak fusion research experiment operated by the United Kingdom Atomic Energy Authority at Culham Campus40,41 (Extended Data Fig. 1). It is a compact, spherical11 device with a major radius of 0.85 m and minor radius of 0.65 m, featuring a double-null design, that is, it has both upper and lower divertors. MAST-U is especially constructed to explore various alternative divertor configurations through its extreme divertor shaping capabilities in the large divertor chamber. This notably includes the Super-X alternative divertor configuration38,39,56. Both divertor chambers are closed off from the main chamber (that is, strongly baffled42) to increase neutral compression, further improving exhaust performance41.

Experimental scenario

The experiments in this work were executed in the second and third MAST-U operating campaigns. We employ a plasma current of 750 kA and we use 1.5-MW South-West Neutral Beam Injection to increase core temperature, leading to increased power flowing into the divertor region. Low-confinement (L-mode) operation was selected over High-confinement (H-mode), as the available H-mode scenario is often more deeply detached compared to L-mode. This causes the ionization front to be out of view of the MWI diagnostic. A build-up of divertor chamber neutral pressure was generally observed in these experiments. The commissioning of the MAST-U cryopumps in the upcoming campaign will probably aid in avoiding this.

A D2 main chamber gas valve located on the low-field side is used for plasma fuelling perturbations, in addition, perturbations were applied with upper and lower divertor valves for some experiments. Density control46 is employed to achieve line-averaged densities of 2–3 × 1019 (m−3) before it is disabled during the perturbation or feedback-control phase of the experiments. In addition to the Conventional divertor, we employ the Elongated and Super-X alternative divertor configurations in this study.

Alternative divertor configurations

Alternative divertor configurations (ADCs) are considered as an exhaust solution for future devices through their superior performance with respect to conventional divertors, with several different designs currently under investigation16,37,57. These designs leverage variations in magnetic topology to enhance particle, power and momentum losses in the divertor region and spread the power over a larger area. This leads to a lower plasma temperature, heat flux and, in some cases, increased access to the detached plasma regime14,15,16. Drawbacks of alternative designs however are engineering complexity (especially in magnetic coil design) and a spatially larger divertor within the vacuum vessel34,37. This leads to increased costs for ADCs in comparison to conventional divertors. Hence, any reactor featuring ADCs has to strike the balance between these drawbacks and the improved performance ADCs offer. ADCs can therefore serve as a risk-mitigation strategy for when conventional divertors cannot withstand the power exhaust in a reactor implementation.

One of the most prominent ADCs, and the focus of this work, is the Super-X divertor38,39,56 (Fig. 1). In this configuration, the total flux expansion (FR) is maximized, that is, maximizing the cross-section area of a flux tube17. For the conventional divertor considered in this paper FR ≈ 1.2, whereas FR ≈ 2.3 for the Super-X configuration16. To achieve this, the strikepoint is placed at large major radius17 as FR 1 / B. This also leads to an increased surface area on which the power is deposited and promotes interaction with neutral particles through an increased particle path of travel (connection length) from X point to target. The Super-X design has demonstrated to substantially improve the target conditions, facilitate an increased access to the detached plasma regime14,15,16 and, in this paper, substantial benefits in handling fast transients.

We also consider the Elongated divertor configuration in this work (Fig. 1). This design only employs moderate total flux expansion (FR ≈ 1.7) compared to the Super-X but has been demonstrated to already achieve substantial performance gains14,15,16.

MAST-U gas system

The MAST-U gas system consists of a collection of piezo-electric gas valves, which connect to the vacuum vessel through pipes, with various injection points in both main chamber and divertor58. Calibrations are used to convert a requested gas flow rate to a voltage, which is subsequently applied to the piezo element. These calibrations are static and hence do not take any gas valve or gas flow dynamics into account. In addition, they assume a linear voltage-to-flow rate relation, which is not accurate near the closing voltage59 and does not take hysteresis of the piezo element into account. The injected gas flow rate, therefore, carries considerable uncertainty46 and is occasionally reported as negative, despite the observation of actual gas flow.

The main chamber valve used in these experiments (Fig. 1) is positioned close to a Dalpha filterscope. The Dalpha intensity measured by this diagnostic represents plasma-neutral interaction and can therefore serve as an indication of the gas system response (Extended Data Figs. 4 and 5). During the experiments presented in this paper, the utilized flow rate was quite low, operating near the gas valve closing voltage, to prevent an extremely detached divertor state where the D2 Fulcher band is out of view of the MWI diagnostic (Fig. 1). Therefore, we can observe some distortion at low voltages, evident as nonlinear components in the frequency domain49. The high signal-to-noise ratio of this Dalpha filterscope measurement allows for a low average noise level, hence, these nonlinear components can be observed.

Dalpha filterscopes positioned in the upper (Fig. 7) and lower (Fig. 6) divertors are employed to also check the functioning of the respective divertor valves. These signals carry more noise compared to the main chamber signals because the divertor filterscopes are toroidally positioned further away from their valves, nevertheless, they clearly show the divertor valve perturbations (Figs. 6 and 7).

D2 Fulcher band emissions

Throughout this work, we use D2 Fulcher band emissions to diagnose the divertor conditions. D2 Fulcher band emissions originate from electronically excited molecules after electron-impact collisions. Strong Fulcher band emissions occurs at 4–5 eV, similar to atomic ionization. Therefore, Fulcher band emissions have been presented as a quantitative method to infer the hydrogen ionization front position14,60. The steep temperature dependence of D2 electronic excitation creates a clearly defined front position, that is, the position of the downstream end of the ionization bulk. This front position can be tracked relatively easily using filtered imaging or spectroscopy. The position of this ionization region is a fundamental indicator of the divertor detachment state14,15,54. Contrary to impurity emissions fronts, which are routinely used to diagnose detachment19,25,53, Fulcher band emissions are unaffected by impurity transport. This results in a more reliable, machine-independent and direct indication of the divertor detachment state.

Inversion-based front tracking

Tracking of the Fulcher band emissions front is achieved using spectrally filtered images from the Multi-Wavelength-Imaging camera system44,61, positioned in the lower divertor of MAST-U (Figs. 1a and 5a,f). The raw camera images from the Fulcher band-filtered channel (Fig. 5a,f) are inverted to obtain a poloidal emissivity profile (Figs. 6c and 7c). The front position is then taken as the position with 50% extinction from the maximum intensity45. The front tracking algorithm outputs Ltar and LX, the distance from the emissions front to the divertor target and X point, measured along the divertor leg in the poloidal plane (Fig. 3d).

The Conventional divertor leg is largely out of view of the MWI diagnostic. Therefore, we employ the newly available X-point Imaging System (XPI) to achieve front tracking for the Conventional divertor in a similar manner. This system was not yet available in the earlier Super-X and Elongated divertor midplane fuelled system identification and feedback-control experiments. Combined XPI and MWI inversions are performed for the tracking of the divertor fuelled system identification experiments (Figs. 6 and 7c).

The MWI, XPI or combined inversions required for this front-tracking method are computationally expensive, hence, front tracking using inverted images is currently only available offline, that is, after the experiment has completed45. Machine-learning-based acceleration techniques have shown promising results62 and might allow for a future extension to real-time operation. In this paper, we employ inversion-based front tracking only for offline analysis of system identification experiments, and we rely on a different routine for real-time front tracking.

Real-time front tracking

Real-time emissions front tracking is achieved using raw, un-inverted camera images directly through a dedicated algorithm first employed in the TCV tokamak51. A dedicated fast coordinate transformation52 is used to achieve the transform from raw camera images to the poloidal plane without requiring camera inversion. Although real-time capable, the coordinate transformation introduces additional noise. We take the front as the 50% extinction from the maximum intensity along the leg, identical to the inversion-based front tracking routine (Fig. 5a,f). In absence of a real-time magnetic equilibrium reconstruction, we prescribe the divertor leg position a priori such that the distance to target along the divertor leg Ltar can be calculated (Fig. 5b,g). The full front tracking algorithm is executed within the 2.5-ms acquisition and processing window of the MWI diagnostic, allowing for 400-Hz operation. The computed front position is fed through an optical-analogue connection into the plasma control system58 where the exhaust controller is located.

The divertor baffle obscures the upper part of the leg (Fig. 2). As the front is defined as an intensity threshold relative to the maximum intensity, tracking is only reliable while the maximum intensity point is in view. The divertor is consistently deeply detached in our experiments and hence, the front is located close to the divertor entrance, but still mostly remains in view (Fig. 5a,f). Tests with a fixed emission threshold (requiring careful tuning) have not shown a notable difference compared to the standard algorithm using a variable threshold. Hence, the obstruction by the divertor baffle has not substantially impacted these experiments.

The use of the fast coordinate transformation52 introduces a requirement for tangential sightlines. A camera system records a two-dimensional projection of a three-dimensional feature, implying that each individual pixel in the camera image records the line-integrated emissions along its sightline. Pixels corresponding to a sightline that is tangent to the light-emitting divertor leg will show a peak in intensity compared to neighbouring sightlines that either intersect or miss the leg52. Therefore, only the sightlines that are tangential to the divertor emissions result in a recognizable divertor leg on the raw camera image, potentially restricting the observable range to only part of the divertor leg.

We analyse the observable region for real-time front tracking through a dedicated geometric analysis and synthetic camera images; Extended Data Fig. 7. We consider both the Elongated (Extended Data Fig. 7a–e) and Super-X (Extended Data Fig. 7f–j) divertor geometries used in the experiments presented in this work and a purely synthetic Super-X divertor variant (Extended Data Fig. 7k–o) for illustrative purposes only. The camera positions, viewing geometry and synthetic camera images are inferred from spatial calibrations obtained through the CALCAM63 software package. The core assumption of this analysis is that the divertor emission is located on the magnetic divertor leg. The sightlines, which are blocked by the divertor tiles, are shown in red whereas the observable sightlines are shown in green (Extended Data Fig. 7a,b,f,g,k,l). In the poloidal plane, a negative dR / dZ is required for a tangential point to exist, otherwise, a sightline will intersect with the plasma by definition. We designate the point where dR / dZ changes sign as the inflection point. Note that although a tangential point might exist, it can still be outside the camera view or be obstructed by the divertor tiles. Such cases have been treated as if no sightline exists. In Elongated geometry, the full leg can be observed from divertor baffle to target. However, for the Super-X divertor geometries, no tangential sightline exists near the target. The location of the inflection point greatly influences the observable region near the target, evident by comparing the two Super-X geometry variants (Extended Data Fig. 7). This is supported by synthetic camera images (Extended Data Fig. 7e,j,o), generated using poloidal emissions profiles with constant emissions intensity along the entire divertor leg (Extended Data Fig. 7e,j,o). The synthetic camera images illustrate how the divertor leg is not observable after the inflection point as determined by the geometric analysis. We therefore conclude that the observable region for emissions front tracking in MAST-U using raw camera images from the MWI diagnostic is bound by the baffle at the divertor entrance and the inflection point near the divertor target.

In the experiments presented in this work, the Super-X divertor is always in a detached state, that is, the Fulcher band emission is far removed from the target. Furthermore, the Super-X geometry features an inflection point location close to the target (Extended Data Fig. 7h). We therefore conclude that the lower limit for real-time front tracking has not influenced these experiments. Nevertheless, the real-time front tracking range can be severely limited for other Super-X divertor geometries (for example, Extended Data Fig. 7m), especially in more attached conditions. The inflection point location should therefore be taken into account when selecting a divertor geometry for feedback exhaust control experiments. Note that these restrictions only apply to the real-time front tracking required for feedback control; the offline inversion-based front tracking method is unaffected.

System identification

We experimentally identify the exhaust dynamics in MAST-U through system identification. This method relies on observing the system response to applied perturbations and has been employed successfully to identify the exhaust dynamics on several devices19,25,64. In addition to allowing for the design of a feedback controller, the experimental identification of exhaust dynamics supports the development of physics-based dynamic models to inform control system design for future devices.

The considered dynamic system (Fig. 1b) includes the gas system, plasma response and MWI sensor dynamics. Note that the dynamics of the piezo-electric gas valve and its associated piping is included in the system (MAST-U gas system section). The system input is the requested flow rate u, the output is the Fulcher band poloidal emission front position Ltar.

We perturb the system input with especially designed signals, consisting of a single sine or a sum of sinusoidal signals. This allows the signal power to be focussed on specific frequencies of interest. We use only a few frequencies per experiment, driven by the low signal-to-noise ratios generally observed in detachment measurements19. The available time for perturbation is only 300–400 ms due to the relatively short <1 s total experiment duration in MAST-U. We require at least three periods per frequency to generate error bars on the data, the lowest frequency within the measurement window is therefore around 8–10 Hz. The upper limit is set by the gas system; above this limit, the gas system will no longer follow the prescribed perturbation signal, taken as roughly 50 Hz (ref. 64).

The perturbation signals consist of integer multiples, or harmonics (f3, f5, f), of the ground frequency (f1). The ground frequency is determined as the lowest frequency which completes thee periods within the measurement window and matches the sampling rates of all considered diagnostics and actuators to prevent aliasing. Generally, only odd frequency components are excited to observe possible quadratic nonlinear effects47,49. However, this quickly drives us towards frequencies above the stipulated 50-Hz gas system limit. Therefore, we occasionally opt to use f1 and f2 or perturb only a single frequency per experiment.

The input and output signals are transformed from the time domain to the frequency domain using the discrete Fourier transform; Extended Data Fig. 2. We estimate an average noise level by taking the average response on the non-exited frequencies, excluding frequencies lower then f1 to remove transient effects49,65. The discrete-Fourier-transform response contains predominantly only excited frequencies well above the average noise level for the considered frequency range, indicating dominantly linear dynamics49. Occasionally, some harmonics do exceed the average noise level (most apparent in Extended Data Fig. 2a). As these nonlinear components are already apparent in the Dalpha filterscope measurement (Extended Data Fig. 4), they originate from the gas system and not the plasma dynamics themselves.

We identify the Frequency Response Function (FRF) of the system by dividing the observed output over input in frequency domain. The Local Polynomial Method is used47,49 to correct for transient effects. The FRF is a local linearization of the input–output dynamics; nonlinear effects will not be captured by the FRF. This is standard practice in control theory and applicable for this predominantly linear system.

STEP fusion power reactor

The Spherical Tokamak For Energy Production (STEP) is a tokamak currently in the concept design phase (Extended Data Fig. 8). It is a highly ambitious programme, targeting completion in the 2040s with the ultimate aim of demonstrating the delivery of fusion power to the UK grid7,8,9,10. The initial design considered in this paper has a major radius of 3.6 m and should deliver 120 MW electrical power. STEP is a spherical tokamak, equipped with two tightly baffled42 divertor chambers which facilitate long-legged divertor configurations, akin to MAST-U (Extended Data Fig. 1). Although it shares a similar design philosophy to MAST-U, its design is fundamentally differently in coping with the neutral irradiation, power cycle, tritium fuel cycle and other requirements placed on a fusion power reactor. Unlike the large divertor volume in MAST-U for facilitating the SXD, the STEP design is less extreme, in some ways resembling the MAST-U ED configuration. The requirement of an exhaust control system for STEP to ensure manageable heat loads is a core driver for the work presented in this paper.

The STEP SOLPS-ITER simulations considered in this work have been published previously as part of a power-sharing study featuring an early design iteration10. The specific simulation considered features a highly detached lower divertor (Fig. 8) through an upward shift in the plasma equilibrium towards an upper single null. This causes the bulk of the power to flow to the upper divertors, leading to a highly detached lower divertor state.