Abstract
Materials emitting circularly polarized light (CPL) are highly sought after for applications ranging from efficient displays to quantum information technologies1,2,3,4,5,6,7. However, established methods for time-resolved CPL (TRCPL) characterization have notable limitations8,9,10,11,12,13,14,15,16,17, generally requiring a compromise between sensitivity, accessible timescales and spectral information. This has limited the acquisition of in-depth photophysical insight necessary for materials development. Here we demonstrate a high-sensitivity (noise level of the order of 10−4), broadband (about 400–900 nm), transient (nanosecond resolution, millisecond range) full-Stokes (CPL and linear polarizations) spectroscopy setup. The achieved combination of high-sensitivity, broad wavelength response and flexible time ranges represents a substantial advancement over previous TRCPL approaches. As a result, TRCPL measurements are shown to be applicable to hitherto inaccessible material systems and photophysical processes, including systems with low (10−3) dissymmetry factors and luminescence pathways spanning nanosecond to millisecond time ranges. Finally, full-Stokes measurements allow tracking the temporal evolution of linear polarization components, of interest by themselves, but especially relevant in the context of controlling for associated CPL artefacts18,19 in the time domain.
Similar content being viewed by others
Main
Materials emitting circularly polarized luminescence have seen a resurgence in research interest over recent years. This is largely driven by emerging and commercially promising technologies using CPL across a broad range in photonics, spin electronics and optoelectronics20,21, including photonic and quantum computing1,2, security inks3, biomedical imaging4, efficient device displays5 and holographic6 and three-dimensional display7 technologies. Accordingly, there is marked interest in the accurate characterization of polarized light emission processes.
Earliest CPL measurements trace back to the mid-twentieth century22,23, and in the following decades, high-sensitivity CPL instruments were developed. Using a photoelastic modulator (PEM) for rapid polarization modulation24,25 followed by lock-in amplification (LIA) or differential photon counting, relative intensity differences of the order of 10−5 are measurable. These basic detection principles continue to underlie most high-sensitivity CPL measurements today. CPL is often characterized by the dissymmetry factor, defined as
where ILCP and IRCP refer to the intensity of LCP (left-handed circularly polarized) and RCP (right-handed circularly polarized) light, respectively.
Although time-resolved measurements are ubiquitous in the characterization of luminescent materials, time-resolved CPL (TRCPL) measurements remain rare. This is despite several TRCPL instruments using PEMs reported in the 1990s (refs. 8,9,10,11,12) alongside applications in revealing racemization and energy transfer dynamics26,27. In particular, a previous study13 used time-correlated single photon counting (TCSPC) and differential photon counting for nanosecond (ns) time resolution and measurement of dissymmetry at the 10−3 level in 1995.
In practice, combining PEMs with time resolution introduces limitations. The modulation rate must be compatible with the detector readout rate, excitation repetition rate and the luminescence decay timescale. As the detection scheme is monochromatic, even steady-state broad-spectrum acquisition is time-consuming18. With TCSPC additionally dividing signal into time bins and limiting detector count rates to about 1–5% of the excitation rate to avoid pile-up, collecting time-resolved CPL spectra becomes impractical (more discussion in Supplementary Information section 4.3). We note that ref. 13 discusses long measurement times in the context of TCSPC-based TRCPL despite MHz excitation rates and a simple filter to select the emission range, already excluding long-lived luminescence and detailed spectra13.
These limitations may be why the few contemporary works in TRCPL14,15,16,17 rely on quarter-wave plates (QWP) instead of modulation, resulting in simpler instruments and faster acquisition. However, the lack of modulation results in low CPL sensitivity. These approaches are, therefore, mostly limited to materials such as chiral lanthanide complexes with extreme dissymmetries28.
However, lanthanide complexes are only a fraction of the diverse material platforms explored at present for CPL applications, many of which feature short-lived (ns) luminescence and/or small dissymmetry factors (around 10−3) (refs. 29,30). Hence, to fuel these developments, TRCPL methods are required that combine sensitive broadband acquisition with the flexibility to probe both fluorescence (ns) and phosphorescence (µs–ms) on their respective timescales.
Measuring principle
Our approach to TRCPL is shown in Fig. 1. An electronically gated charge-coupled device (CCD) camera allows flexible time gates from 2 ns to several milliseconds (ms), is inherently broadband, and is not limited by photon pile-up effects. To achieve high sensitivity without polarization modulation, we simultaneously record orthogonal linear polarizations on different parts of the CCD array (2,048 × 512 pixels), as recently applied in ref. 31 for calibration-free error cancelling in a steady-state CPL spectrometer and previously used in fluorescence correlation time imaging32. The reader is referred to these works for an excellent coverage of the theory and associated errors. Error cancelling enables sensitive measurements of dissymmetry, with noise floors of the order of 10−4 for sufficiently bright luminescence. Using a single CCD further eliminates issues with channel synchronicity and reduces overall cost and complexity compared with dual-detector approaches17.
a, Schematic of the key optical components and measurement procedure. Excitation by a pulsed laser (200 fs, variable repetition rate 0.5–50 kHz) in the 90° geometry eliminates certain polarization artefacts, whereas the 180° geometry is more suitable for thin samples. Superachromatic waveplates (HWP for half-wave plate, QWP for quarter-wave plate) in appropriate orientations transform polarization components into orthogonal linear components, which are separated by a Wollaston prism and passed through a grating spectrograph. Orthogonally polarized spectra are recorded simultaneously as two tracks on a single CCD array detector. An intensifier tube is electronically gated to provide time resolution. Waveplate rotation, automatable by motorized housings, allows swapping the detection tracks, which results in the cancellation of the largest channel transmission mismatches and temporal instabilities. b, Calculated intensities at vertical and horizontal detection tracks as a function of QWP angle for an RCP luminescence input and HWP angle for a linearly polarized input. Two tracks are simultaneously recorded, and the measurement is repeated at a second QWP/HWP position at which the tracks swap. c, Calculated intensity difference between measurement tracks as a function of both QWP and HWP angle for the pure Stokes basis polarizations. Red crosses indicate angles where measurements are taken for that polarization component. For reference, black crosses (each of which is at ΔI = 0) indicate angles where measurements are taken for other polarization components.
Polarization components are separated by a series of polarization optics consisting of a half-wave plate (HWP), QWP and a Wollaston prism. Repeating measurements for a series of waveplate angles allows for cancellation of various error sources31 and isolation of specific polarization components. Waveplate interactions with different polarization states are shown in Fig. 1c. At suitable angle combinations, only a specific component of the Stokes vector is translated to the intensity difference between channels. Accordingly, linear polarization components in luminescence (a primary error source in CPL measurements18) can be quantified apart from CPL. This results in a sensitive, time-resolved broadband measurement of the full Stokes vector. More detail is given in the Methods and Supplementary Information sections 1, 2 and 4.
We note that the relative angle and polarization of the excitation beam with respect to the collection optics (common configurations shown in Fig. 1a) result in varying photoselection effects19 and can affect the polarization of collected luminescence (Methods and Supplementary Information section 4.1). These effects can be especially relevant in time-resolved studies, if relaxation of dipole orientations occurs slower than the measurement time resolution33. Besides photoluminescence, circularly polarized electroluminescence (CP-EL), for example, from a spin-LED, could equally be characterized instead.
For the remainder of this work, we showcase setup performance with data collected on small molecules in solution with varying degrees (strong, weak and none) of CPL dissymmetry and excited-state timescales from single-ns to >100 μs.
Chiral lanthanide complex
Steady-state and microsecond gating of Eu[(+)-facam]3 luminescence
Lanthanide complexes with chiral ligands often show strong CPL28,34. In particular, Eu[(+)-facam]3 ((+)-facam = 3-(trifluoromethylhydroxymethylene)-(+)-camphorate; structure shown in Fig. 2) is commercially available and possesses high emission dissymmetry (glum reaching −0.78 in dry DMSO at 595 nm) (ref. 24). As such, Eu[(+)-facam]3 is a common standard for CPL setup validation and testing for which multiple literature sources exist for comparison18,24. These reports include a recent CCD-based CPL setup with time gating functionality17 and fully time-resolved studies in ref. 16, which shows the temporal evolution of dissymmetry with approximately 10 μs resolution and millisecond range.
Structure of the chiral standard Eu[(+)-facam]3 is shown at the top right. a, Total steady-state luminescence intensity (405 nm continuous wave excitation, 450 nm long-pass filter). The inset shows weak emission on the blue side, partially cut off by the filter. b, Steady-state CPL spectrum showing the intensity difference ∆I between LCP and RCP luminescence, normalized to the maximum total luminescence intensity. The main CPL features are labelled, 5D0 → 7F1 near 595 nm and 5D0 → 7F2 near 615 nm. c, Steady-state spectrum of the luminescence dissymmetry factor glum. d, Time-resolved total luminescence spectra (343 nm excitation pulsed at 500 Hz, 50 µs time bins) at selected gate delays. e, Time-resolved CPL spectra at selected gate delays. f, Time-resolved spectra of the luminescence dissymmetry factor at selected gate delays. g, Intensity and dissymmetry factors as a function of time at the 5D0 → 7F2 peak. h, Intensity and dissymmetry factors as a function of time at the 5D0 → 7F1 peak (small upticks at 450 μs in g and 650 μs in h are probably because of cosmic rays).
To establish comparison with existing literature, we first present steady-state and long timescale time-resolved (50 μs gate width) CPL spectra of Eu[(+)-facam]3 in dry DMSO (Fig. 2). The sharp emission features in this complex arise from f–f transitions of the Eu3+ centre, which generally are of the form \(\genfrac{}{}{0ex}{}{\,5}{}{D}_{{J}_{1}}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\) (where J1, J2 are the total angular momentum quantum numbers) and can be assigned to \(\genfrac{}{}{0ex}{}{5}{}{D}_{0}\,\to \,\genfrac{}{}{0ex}{}{7}{}\,{F}_{{J}_{2}}\) transitions specifically35,36,37. Of these, the most striking CPL features appear at 595 nm and 613 nm, corresponding to a 5D0 → 7F1 magnetic dipole transition and a 5D0 → 7F2 induced electric dipole transition, with reported glum values of –0.78 and +0.072, respectively16,18,24 (although with some variance and environmental sensitivity38, notably to water16).
In the steady state, our luminescence and CPL spectra match literature (Fig. 2a–c), although the recorded glum of −0.745 for the 5D0 → 7F1 transition is slightly lower than expected. Besides potential issues with, for example, water ingress, a possible explanation is the relatively coarse grating necessary for broadband acquisition and finite detector pixel size resulting in a wavelength resolution limit of about 1 nm, similar to the line width of the feature (see Supplementary Fig. 19 for effects of water contamination and Supplementary Fig. 10 for the effects of slit width on measured glum).
Although the time-resolved luminescence spectra (Fig. 2d–f) show little evolution of the spectral shape over time, the magnitude of glum changes (Fig. 2g,h). The reduction in glum over time is similar to what was observed in ref. 16, in which a decrease from a peak value of approximately −0.8 with a time constant of approximately 1 ms is reported and assigned to sample heterogeneity. Moreover, our data show an increase in glum for the first few time bins. This is more apparent for the 5D0 → 7F1 peak (Fig. 2h) than the 5D0 → 7F2 peak (Fig. 2g). The early-time rise in glum is possibly linked to weak transitions seen on the blue side in the earliest time bins (Fig. 2d, inset), which will overlap more with the 5D0 → 7F1 peak at 595 nm than the 5D0 → 7F2 peak at 613 nm. These features are also faintly visible in the steady-state measurement (Fig. 2a, inset), although partially cut off by the filter. These early-time features are investigated in more depth in the next section. A flat or slightly rising glum at early times is also reported in ref. 16, although in this study, the earliest time points were not sampled. Overall, both steady-state and μs-timescale time-resolved measurements are consistent with the literature for Eu[(+)-facam]3 in DMSO.
Nanosecond polarization dynamics of Eu[(+)-facam]3
Having established a comparison with available literature in the steady-state and μs-timescale TRCPL of Eu[(+)-facam]3 in DMSO, we turn to TRCPL on single-ns timescales (Fig. 3). To the best of our knowledge, this is the first report of such data.
a, Non-polarization sensitive luminescence spectra (excitation 343 nm, 200 fs and 500 Hz) with varying time bins, normalized by maximum value to highlight spectral changes. Key early-time spectral features are labelled as the broad peak around 400–500 nm (LC), and a series of peaks at 520–600 nm (\(\genfrac{}{}{0ex}{}{\,5}{}{D}_{1}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\)). b, Kinetic traces of the non-polarization sensitive luminescence signal, at wavelengths corresponding to key features in spectra. c–e, Time-resolved CPL spectra (excitation 343 nm, 200 fs and 50 kHz) with 5 ns bins using horizontal excitation polarization to avoid photoselection. The transition 5D1 → 7F2 at 560 nm is shown magnified in an inset and labelled. f–h, Time-resolved S1 linear polarization measurement (excitation 343 nm, 200 fs and 50 kHz) with 2 ns bins and 0.5 ns steps, using vertical excitation polarization to intentionally induce photoselection (note that because of the time step and bin width, early-time bins fall within instrument response).
The time-resolved luminescence spectra (Fig. 3a) show several features at early times apart from the aforementioned \(\genfrac{}{}{0ex}{}{5}{}{D}_{0}\,\to \,\genfrac{}{}{0ex}{}{7}{}\,{F}_{{J}_{2}}\) transitions. Most prominent is a broad unstructured peak around 435 nm (exact peak position may be affected by transmission and sensitivity at the blue edge), with a series of narrower peaks in the 520–570 nm range. To assign these early-time Eu[(+)-facam]3 features, we briefly discuss the photophysics of europium(III) complexes35. The Eu3+ ion has several well-studied spectral lines arising from \(\genfrac{}{}{0ex}{}{5}{}{D}_{1}\,\to \,\genfrac{}{}{0ex}{}{7}{}\,{F}_{{J}_{2}}\) transitions37,39. These transitions are weakly absorbing (being magnetic dipole transitions or Laporte forbidden electric dipole transitions40,41), but strongly absorbing ligands with suitable energy levels can act as antennae that sensitize the luminescent f–f excited states in the lanthanide ion42.
Initially, a ligand-centred state (1LC) is excited, which can transfer the energy to the Eu3+ ion after intersystem crossing (ISC) to a 3LC triplet state43. Incomplete ISC or energy transfer can result in LC-state luminescence44. As energy transfer occurs preferentially via the 5D1 level45 per the respective selection rules, emission from 5D1 (and even the higher-energy states 5D2 and 5D3) is occasionally observed, typically with a much shorter decay time than the main 5D0 emission35.
The features observed for Eu[(+)-facam]3 are consistent with such a mechanism, showing features consistent with LC, \(\genfrac{}{}{0ex}{}{5}{}{D}_{1}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\) and \(\genfrac{}{}{0ex}{}{5}{}{D}_{0}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\) with progressively longer lifetimes. Kinetics at various wavelengths are collected in Fig. 3b, and multi-exponential fits are collected in Supplementary Fig. 6). Owing to multiple timescales and overlapping features (LC and \(\genfrac{}{}{0ex}{}{5}{}{D}_{1}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\) luminescence have different lifetimes, and \(\genfrac{}{}{0ex}{}{5}{}{D}_{0}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\) luminescence has previously been reported as biexponential16), extracting robust lifetimes is difficult. Estimated timescales are 13 ns for the LC peak and 130 ns for the \(\genfrac{}{}{0ex}{}{5}{}{D}_{1}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\) lines. Both are short-lived compared with the \(\genfrac{}{}{0ex}{}{5}{}{D}_{0}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\) lines (lifetimes of the order of 100 μs), which dominate steady-state measurements.
To determine the CPL activity of early-time luminescence pathways, we have performed a time-resolved CPL measurement with gate steps and widths of 5 ns (Fig. 3c–e). For minimizing photoselection effects, a horizontal excitation polarization was used. To achieve a sufficient signal-to-noise ratio for CPL, a 50-kHz laser repetition rate was necessary, and, therefore, some roll-over emission is present (data with 50 ns gate steps and 500 Hz repetition rate to avoid roll-over is shown in Supplementary Fig. 8). Both LC and \(\genfrac{}{}{0ex}{}{5}{}{D}_{1}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\) luminescence are observed. The ligand-centred transition does not seem to be discernibly CPL-active. Even if some dissymmetry were present, we might expect this to be far smaller than that of Eu3+ transitions and within the noise level of this measurement. By contrast, some \(\genfrac{}{}{0ex}{}{5}{}{D}_{1}\,\to \,\genfrac{}{}{0ex}{}{7}{}{F}_{{J}_{2}}\) transitions possess evident luminescence dissymmetry. In particular, the 5D1 → 7F2 transition around 560 nm shows strong bisignate CPL with |glum| ≈ 0.2 as might be expected, because it is a magnetic dipole transition similar to the strongly dissymmetric 5D0 → 7F1 transition at 595 nm (ref. 40).
To rule out ns-timescale linear polarization artefacts, we intentionally induced photoselection by exciting Eu[(+)-facam]3 with vertically polarized light and performed an S1 linear polarization measurement with 2 ns oversampled (partially overlapping) time bins (Fig. 3f–h). Linear polarization is measured in the LC emission band, almost completely disappearing within the instrument response (around 2 ns). Eu3+ features exhibit far less linear polarization, as might be expected, because these states are populated by energy transfer and not direct excitation. Our results are consistent with strong photoselection of ligand dipoles followed by rapid reorientation on a timescale within the instrument response (2 ns). Even when intentionally maximized, substantial linear polarization is not present on timescales used for the CPL measurements in Fig. 3c–e, increasing our confidence in those findings.
To summarize, TRCPL with ns time resolution allows us to observe several short-lived electronic transitions in a europium(III) complex and evaluate their CPL activity for the first time. Hence, the method provides a handle to uncover signals that are otherwise suppressed in steady-state and microsecond time-resolved measurements but may be crucial for understanding photophysical relaxation pathways.
Chiral organic TADF emitter
Although CPL-active lanthanide complexes provide a convenient benchmark, studies on chiral emitters often involve materials with much weaker dissymmetry and faster luminescence decay. For example, purely organic small molecules in solution rarely exceed dissymmetry factors of 10−2 even in best-performing materials30,46. Hence, we demonstrate the broad applicability and sensitivity of our TRCPL setup using a CPL-active organic molecule. To introduce multiple luminescence timescales, we used a chiral organic dye (R/S)-BINOL-phthalonitrile-tBuCz ((R/S)-BPC; Fig. 4), which shows thermally activated delayed fluorescence (TADF) and for which only steady-state CPL has been previously measured47.
Structure of the chiral TADF-active dye BPH is shown at the top right. a–c, Steady-state CPL spectra of (R)- and (S)-enantiomers (excitation 343 nm, 200 fs, 12.5 kHz). d–f, Time-resolved CPL spectra of the (R)-enantiomer. ‘Prompt’ refers to the first 100 ns, ‘Delayed’ refers to approximately 500 ns–80 μs, and ‘Total’ refers to a gate covering the complete emission process (0–80 μs). g, Kinetic trace of the total intensity decay integrated over the full spectrum, with highlighted regions showing the ‘Prompt’ and ‘Delayed’ time regions and parameters of a biexponential fit (red trace). h, Kinetic traces of the dissymmetry factor (average from 445–455 nm) and total intensity decay (integrated over 400–450 nm) with 3 ns time bins and 1 ns steps for the S-enantiomer (50 kHz repetition rate).
Steady-state CPL spectra of the two enantiomers in toluene solution show the expected mirror-image CPL (Fig. 4a–c) with glum values of +1.8 × 10−3 (R) and –1.3 × 10−3 (S) at the luminescence peak, matching previous reports (|glum| = 1.6 × 10−3) (ref. 47). To introduce time resolution, we performed two experiments: first, we separately gated the prompt, delayed and total emission components of R-BPC (Fig. 4d–f). The kinetic trace of the total emission (Fig. 4g) shows a biexponential decay process. Compared with the delayed component, prompt emission is much shorter-lived (23 ns compared with 18 μs), but more than 10,000 times more intense. Consequently, the total emission spectrum is dominated by prompt emission and prompt and total spectra overlap (Fig. 4d). There is a slight unexpected spectral shift between the prompt and delayed components. For TADF, the luminescent state is expected to be the same (1CT) in both time regimes. In principle, the shift could arise from delayed fluorescence overlapping with another triplet-mediated luminescence pathway. Regardless, the dissymmetry of the delayed component is not meaningfully affected, and the CPL/glum spectra (Fig. 4e,f) are indistinguishable within noise for the different components. This not only confirms that the measurement is sensitive enough to accurately quantify glum of the order of 10−3, but it can also do so reliably for a temporally separated emission component comprising less than 3% of the total emission intensity.
Finally, we demonstrate ns-scale kinetic traces of weak CPL with S-BPC (Fig. 4h). The first few bins show a rise caused by the instrument response. As convolution and division are not commutative, dissymmetry factors in this region should not be interpreted48. The measured glum remains constant over the remaining part of the measured 15-ns time range, demonstrating the ability to track glum values of the order of 10−3 on ns timescales. Temporal characterization of CPL in this material, which combines ns-scale and μs-scale decays with glum of the order of 10−3, would not be feasible with pre-existing techniques.
Polarization artefacts and relaxation in achiral dye
Finally, using the achiral dye rhodamine B (Fig. 5), we demonstrate the low-noise zero baseline of our setup when photoselection is minimized, and the time evolution of various apparent polarization components when photoselection is induced on purpose.
Structure of rhodamine B is shown at the top right. a–c, Steady-state Stokes vector measurements (excitation 515 nm, 200 fs and 50 kHz) in a low-viscosity environment with horizontal (h) and vertical (v) excitation polarizations to inhibit and induce photoselection effects, respectively. Vertical excitation polarizations correspond to solid lines, and horizontal excitation polarizations to dashed lines. We point out that all spectra overlap in a, and in b and c the dashed lines are all flat about 0. d–f, Time-resolved intensity differences (excitation 515 nm, 200 fs and 50 kHz) over the Stokes polarization basis (normalized to total intensity maximum) in a high-viscosity environment with vertical excitation polarization to induce photoselection. g, Time evolution of all three Stokes components (averaged over a 10 nm range about the emission peak) in low-viscosity and high-viscosity environments with vertical excitation polarization (2 ns time bins and 0.5 ns time steps).
First, we measured the steady-state luminescence spectra of rhodamine B in water as a relatively low-viscosity environment with different excitation polarizations (Fig. 5a–c). Specifically, we used horizontal excitation polarization to minimize and vertical excitation polarization to intentionally maximize photoselection effects. The total emission spectrum is not affected by the excitation polarization (Fig. 5a) and horizontally polarized excitation yields a flat baseline about 0 with noise on the order of 10−3 or below for all polarization components S1, S2 and S3, as expected for an achiral molecule (Fig. 5b,c, dashed lines; also see Supplementary Fig. 13 for measurements showing S1/2/3 noise levels pushed to the order of 10−4).
When vertically polarized excitation is used, non-zero values for all polarization components appear (Fig. 5b,c, solid lines).
Expectedly, the S1 component (horizontal–vertical linear polarization) shows the greatest response (the S2 component at 45°/135° linear polarization may partially arise from a slight tilt of the excitation beam, so the excitation polarization is not perfectly vertical along the detection axis).
Importantly, we observe a substantial non-zero S3 component for an achiral sample, that is, a CPL artefact. CPL artefacts induced by linear polarization components are the main challenge in accurate CPL measurements18,19 across setup designs31. They are usually attributed to imperfections in the optical components, such as residual static birefringence and circular dichroism18,31.
For time-resolved CPL measurements, it is important to understand how the temporal evolution of linear polarization components translates to CPL artefacts. This requires time-evolving linear polarization luminescence on sufficiently long timescales to be measured.
In solution, photoselection-induced linear polarization decays as the excited molecules rotate and randomize the orientation of their transition dipoles. To vary the rotational relaxation times of our fluorophore and thus the linear polarization decay times, we increased the solvent viscosity49 by adding sucrose. This is an alternative to changing solvents completely, as the luminescence of rhodamine B is solvent-dependent50.
In a high-viscosity environment with maximized photoselection, a very large S1 component is present immediately after excitation (Fig. 5d) and decays over time. Smaller S2 and S3 components are also measured and depolarize over time (Fig. 5e,f). Their spectral shape and magnitude relative to S1 are consistent with the steady-state measurements in a low-viscosity medium (Fig. 5b).
Time evolution of the Stokes parameters about the luminescence peak in low- and high-viscosity solutions is shown in Fig. 5g. For the low-viscosity solution, depolarization is almost complete within the instrument response and the Stokes parameters are subsequently clustered around 0. For the high-viscosity solution, emission remains partially polarized after 10 ns, tracing an approximately straight line through the S1/S2/S3 space (Fig. 5g). The S3 component, representing a CPL artefact, is therefore proportional to the real S1 component (although considerably smaller in magnitude).
Our results reaffirm the importance of linear-polarization-induced CPL artefacts and, consequently, the importance of measuring linear polarization components. Even in isotropic samples, linear anisotropy may be induced by photoselection, and especially for high-viscosity solutions or solid-state samples these effects can influence the luminescence polarization dynamics. Even in these cases, the impact can be minimized by appropriate measurement parameters.
Conclusion and discussion
We developed time-resolved broadband full-Stokes-vector luminescence spectroscopy as a versatile method for the polarization-resolved investigation of excited-state dynamics. Our design establishes broadband ns time resolution at ms range with a sensitivity noise floor of the order of 10−4.
We then demonstrated the use of this setup in probing various timescales and degrees of CPL activity.
First, we validated our setup using the CPL standard Eu[(+)-facam]3, for which we reproduced previously reported steady-state and μs-scale time-resolved spectra. Leveraging the ns time resolution of our instrument, we showed the polarization-resolved luminescence dynamics of ligand-centred excited states and high-energy f–f transitions in Eu3+.
The high sensitivity of our method allowed us to track the temporal evolution (early-time ns to late-time µs) of weak CPL signals in a chiral TADF emitter with dissymmetry factors of the order of 10−3, marking the first CPL dynamics report of such a material.
Last, we mapped out the temporal dynamics of polarization components and artefacts covering the full Stokes vector by deliberately introducing photoselection in an achiral dye. We show that CPL artefacts may also show time dynamics for certain timescales and experimental parameters, but also show that such artefacts can be effectively mitigated with appropriate experimental design.
To facilitate adoption by the wider community, we share the full setup design, along with the algorithms used for measurement automation. Furthermore, we provide a compendium of practical considerations, including non-obvious error sources such as beam deviation and variations in detector pixel sensitivity. These factors open new avenues to further push the limits of sensitivity and time resolution in the future, for example, by using optical gating for covering ultrafast timescales.
Overall, broadband time-resolved full-Stokes luminescence spectroscopy greatly expands the sensitivity, timescale and scope of accessible polarization information compared with the state-of-the-art methods. Importantly, this is achieved while retaining a straightforward design using stock components. We hope that our work will fuel the development of next-generation high-performance optical materials by revealing their underlying dynamics with unprecedented detail.
Methods
Separation of polarization components of sample luminescence
A schematic of the setup with specifications and part numbers of the main components are provided in Supplementary Fig. 1 and Supplementary Information section 1.1.
Sample luminescence is collected by a lens and passed through a set of polarization optics consisting of a superachromatic HWP, a superachromatic QWP and a 1° Wollaston prism. The HWP and QWP are placed in motorized rotation mounts, whereas the Wollaston prism remains fixed. After the polarization optics, the luminescence is focused onto a (vertical) spectrograph slit by a lens. The result is a free-space configuration with no fibre coupling or mirrors between the sample and spectrograph.
Polarization tracks are spatially separated (vertically) from the single luminescence beam by the fixed Wollaston prism. Therefore, one track will always correspond to a vertical polarization and the other to a horizontal polarization (which we will call horizontal and vertical tracks accordingly). Tracks are passed to a grating and focused onto an intensified CCD 2D-array detector (ICCD).
An illustration of how the various Stokes components produce intensity differences between the tracks in the ideal case with both a HWP and QWP present is presented in Fig. 1c. Waveplate orientations are defined about the fast axis relative to the table plane. Rotation of waveplates results in projecting the luminescence polarization components of interest (0°/90°, +45°/−45°, LCP/RCP for S1, S2 and S3, respectively) onto the horizontal or vertical tracks. The other waveplate orientation (varied by 45°/90° from the first for the HWP/QWP, respectively) is then used to swap the polarization components between the tracks. This combination of simultaneous (orthogonal polarizations measured at the same time on different tracks) and sequential (orthogonal polarizations measured on the same track after waveplate rotation) measurements allows for cancellation of major errors due to different transmissions along the two beam paths and time instability as previously described31.
We note that it is in principle possible to only use an HWP for conducting an S1/S2-only measurement and to only use a QWP for an S3-only measurement. Yet, for a faster, fully automatable full-Stokes measurement, it is advantageous to have both waveplates in place for all measurements. In all cases, the waveplate angles for measuring a given Sn component are such that the other two components are split evenly across the two channels and, therefore, are not measured as a false polarization signal in the ideal case. Importantly, for CPL measurements, the HWP orientation in principle does not matter, but in all orientations, the HWP will act to transform LCP to RCP and vice versa, which must be accounted for in processing.
Imperfections in real-life optics can produce polarization artefacts, including the well-known false CPL signals when substantial linear polarization is present18. It is, therefore, advisable in polarization measurements to take care when interpreting small polarization components in the presence of other, larger polarization components.
Excitation/collection geometry and excitation polarization
Sample excitation is possible in various configurations, defined by the relative angle and polarization of the excitation beam with respect to the collection optics. In general, artefact-free CPL measurements are possible in two configurations: (1) with 90° excitation/collection geometry and horizontal excitation polarization or (2) with 180° excitation/collection and unpolarized excitation polarization19.
All data presented in this work were collected from solution samples, for which the 90° excitation/collection geometry with square-based four-window cuvettes was found to be the most straightforward approach (more details in Supplementary Information section 4.1). In this geometry, photoselection effects in collected luminescence (affecting the degree of induced linear polarization) can be minimized by using a horizontal excitation polarization and maximized by a vertical excitation polarization.
Horizontally polarized excitation was used for artefact-free CPL measurements. Vertically polarized excitation was used to intentionally induce photoselection and linear components in luminescence.
Excitation beam polarization states were set using a HWP and linear polarizer after the excitation light source.
Sample preparation and measurement conditions
Eu[(+)-facam]3 was used as received from the supplier (Sigma-Aldrich). Rhodamine B was used as received from the supplier (Radiant Dyes). (R/S)-BINOL-phthalonitrile-tBuCz was synthesized according to previously described methods47.
Solution concentrations were 0.5 mM (non-polarization-resolved measurements) and 11 mM (polarization-resolved measurements) for Eu[(+)-facam]3 in DMSO, 0.6 mM for (R/S)-BINOL-phthalonitrile-tBuCz in toluene, 37 μM for rhodamine B in water, 33 μM for rhodamine B in a water:sucrose mixture.
Solution samples were prepared using anhydrous solvents in a nitrogen-filled glovebox, except for aqueous solutions of rhodamine B, which were prepared under ambient conditions. Aqueous solutions were prepared using distilled water. For high-viscosity solutions, sucrose was dissolved in water near the solubility limit (approx. 2 g ml−1). The Eu[(+)-facam]3 solution in ‘wet’ DMSO was prepared by adding 0.5% v/v deionized water to the 11 mM Eu[(+)-facam]3 solution, in which the solution was measured 5 h after the addition of water, similar to the methodology described in ref. 16.
Solutions were placed in screw-top four-windowed quartz cuvettes with a 1-cm square base. Air ingress to cuvettes was reduced by further sealing with PTFE tape and parafilm within the glovebox, where appropriate. Solutions were measured at ambient temperature in a laboratory with controlled and monitored temperature, recorded as 21 ± 0.3 °C for all measurements.
Sample excitation
For time-resolved measurements, samples were optically excited using the output of a Light Conversion PHAROS laser (Yb:KGW lasing medium, 1,030 nm, pulse energy 400 μJ, pulse width duration 200 fs and repetition rate of 50 kHz). The pump beam was generated from the seed in a harmonic generation unit (Light Conversion HIRO) by nonlinear crystals (beta-barium borate and lithium triborate) with residual fundamental removed by dichroic mirrors within the unit. Second and third harmonics can be generated, giving pump wavelengths of 515 nm or 343 nm, respectively. Other excitation wavelengths were generated using an optical parametric amplifier (Light Conversion ORPHEUS-NEO). Pump pulse energy at the sample was 10–70 nJ, with the pump focused down to a beam diameter of approximately 1 mm on the sample. The laser repetition rate is controllable by a pulse picker, and repetition rates in the range of 0.5–50 kHz were used as specified, where data are presented.
For continuous wave excitation at 405 nm, a laser diode (ThorLabs DL5146-101S mounted in a ThorLabs LDM9T temperature-controlled mount) was used, with a constant output power of 5–50 mW.
Signal collection and time ranges
The ICCD sensor has 2,048 × 512 pixels, enabling simultaneous recording of multiple tracks. Horizontal and vertical polarization components, spatially separated (on the vertical axis) by a Wollaston prism, are simultaneously recorded. The spectrograph grating splits the wavelengths in both tracks horizontally across the sensor. Vertical pixel binning is used to produce two effective vertical pixels for each wavelength pixel, giving Ih(λ) and Iv(λ) for the horizontal and vertical channels, respectively.
The intensifier of the ICCD only passes through a signal when a gate pulse is applied across it. Setting gate pulse values allows for adjusting the time over which luminescence is measured. For time-resolved measurements, the quantities recorded during a single acquisition are Ih(λ, t) and Iv(λ, t), where t is defined by the gate pulse applied. Time series are built up by repeating the measurement with modified gate delays and widths.
Accessible time bins range from approximately 2 ns to 2 ms for the described setup, with the lower limit arising from the intensifier specifications. The upper limit is practically limited by the laser repetition rate, as very long gate pulse values are achievable. In our setup, the laser operates at 50 kHz and can be pulse-picked for a lower frequency operation at the same per-pulse fluence (and lower time-averaged power). The practical limit for sufficient luminescence for measurements was found to be approximately 500 Hz, corresponding to a maximum time range of 2 ms; extending this would be reasonably straightforward by increasing per-pulse power at the sample, in principle.
For time-averaged values, comparable to steady-state measurements, a bin size spanning the entire time period between excitation pulses (or at least the time period during which luminescence is present) can be used with a pulsed excitation. Alternatively, the setup can be switched to a continuous wave excitation source, in which case only a time-averaged value is measured regardless of detector time gating.
Data processing
Error cancellation and changing the Stokes polarization component measured require repeating the measurement with rotated waveplates. Subsequent data processing to remove dark background signals and obtain error-corrected polarization spectra and related quantities was carried out with simple scripts. Algorithms for measurement automation are presented in Supplementary Information section 5.
To denote the orientations of the HWP and QWP, we will call the recorded intensities Iv,QWPθ,HWPθ and Ih,QWPθ,HWPθ and drop the wavelength/time label for conciseness. The exact series of performed measurements depends on the specific experiment.
A simple S3 measurement measures ILCP and IRCP, recorded as
From this, we may calculate the quantities
with analogous processing steps for the linear components S1 and S2 for different waveplate angles and LCP/RCP replaced by the appropriate linear polarization axes (0°/90° and +45°/−45°, respectively). These are shown in Supplementary Information section 2.
Where appropriate, the transmission curve of long-pass filters used was measured and corrected for in data processing. Transmission characters of other optical components were not corrected for.
Data availability
Raw and processed data underlying the plots in this paper are available at Zenodo (https://doi.org/10.5281/zenodo.15360970)51. Source data are provided with this paper.
Code availability
Pseudocode describing the applied algorithms is provided in the Supplementary Information. The Python implementation for hardware control, which relies on a proprietary software development kit (SDK) for the specific camera used and therefore cannot be publicly released, is available from the corresponding author upon reasonable request.
References
Mair, A., Vaziri, A., Weihs, G. & Zeilinger, A. Entanglement of the orbital angular momentum states of photons. Nature 412, 313–316 (2001).
Aiello, C. D. et al. A chirality-based quantum leap. ACS Nano 16, 4989–5035 (2022).
MacKenzie, L. E. & Pal, R. Circularly polarized lanthanide luminescence for advanced security inks. Nat. Rev. Chem. 5, 109–124 (2021).
Stachelek, P., MacKenzie, L., Parker, D. & Pal, R. Circularly polarised luminescence laser scanning confocal microscopy to study live cell chiral molecular interactions. Nat. Commun. 13, 553 (2022).
Wan, L., Liu, Y., Fuchter, M. J. & Yan, B. Anomalous circularly polarized light emission in organic light-emitting diodes caused by orbital–momentum locking. Nat. Photon. 17, 193–199 (2023).
Wang, Q. et al. Reflective chiral meta-holography: multiplexing holograms for circularly polarized waves. Light Sci. Appl. 7, 25 (2018).
Zhang, M. et al. Processable circularly polarized luminescence material enables flexible stereoscopic 3D imaging. Sci. Adv. 9, eadi9944 (2023).
Metcalf, D. H. et al. Excited-state chiral discrimination observed by time-resolved circularly polarized luminescence measurements. J. Am. Chem. Soc. 111, 3082–3083 (1989).
Blok, P. M. L., Schakel, P. & Dekkers, H. P. J. M. Time-resolved and continuous-wave circular polarisation of luminescence spectroscopy using a commercial spectrofluorimeter. Meas. Sci. Technol. 1, 126–130 (1990).
Rexwinkel, R. B., Schakel, P., Meskers, S. C. J. & Dekkers, H. P. J. M. Time-resolved polarization of luminescence spectroscopy: an accurate and versatile digital instrument for the sub-μs time domain. Appl. Spectrosc. 47, 731–740 (1993).
Schauerte, J. A., Gafni, A. & Steel, D. G. Improved differentiation between luminescence decay components by use of time-resolved optical activity measurements and selective lifetime modulation. Biophys. J. 70, 1996–2000 (1996).
Schauerte, J. A., Steel, D. G. & Gafni, A. Time-resolved circularly polarized protein phosphorescence. Proc. Natl Acad. Sci. USA 89, 10154–10158 (1992).
Schauerte, J. A., Schlyer, B. D., Steel, D. G. & Gafni, A. Nanosecond time-resolved circular polarization of fluorescence: study of NADH bound to horse liver alcohol dehydrogenase. Proc. Natl Acad. Sci. USA 92, 569–573 (1995).
De Rosa, D. F., Stachelek, P., Black, D. J. & Pal, R. Rapid handheld time-resolved circularly polarised luminescence photography camera for life and material sciences. Nat. Commun. 14, 1537 (2023).
Frawley, A. T., Pal, R. & Parker, D. Very bright, enantiopure europium(III) complexes allow time-gated chiral contrast imaging. Chem. Commun. 52, 13349–13352 (2016).
Hananel, U. et al. Time-resolved circularly polarized luminescence of Eu3+-based systems. Chirality 33, 124–133 (2021).
MacKenzie, L. E., Pålsson, L.-O., Parker, D., Beeby, A. & Pal, R. Rapid time-resolved circular polarization luminescence (CPL) emission spectroscopy. Nat. Commun. 11, 1676 (2020).
Kitzmann, W. R., Freudenthal, J., Reponen, A.-P. M., VanOrman, Z. A. & Feldmann, S. Fundamentals, advances, and artifacts in circularly polarized luminescence (CPL) spectroscopy. Adv. Mater. 35, 2302279 (2023).
Blok, P. M. L. & Dekkers, H. P. J. M. Measurement of the circular polarization of the luminescence of photoselected samples under artifact-free conditions. Appl. Spectrosc. 44, 305–309 (1990).
VanOrman, Z. A. et al. Chiral light–matter interactions in solution-processable semiconductors. Nat. Rev. Chem. 9, 208–223 (2025).
Crassous, J. et al. Materials for chiral light control. Nat. Rev. Mater. 8, 365–371 (2023).
Samoilov, B. N. Absorption and luminescence spectra of uranyl salts at temperatures of liquid helium; Spektry Pogloshcheniya i Luminestsentsii Uranilovykh Solei pri Temperature Zhidkogo Geliya. Zhur. Eksptl. i Teoret. Fiz. 18, 1030–1040 (1948).
Emeis, C. A. & Oosterhoff, L. J. Emission of circularly-polarised radiation by optically-active compounds. Chem. Phys. Lett. 1, 129–132 (1967).
Schippers, P. H., van den Buekel, A. & Dekkers, H. P. J. M. An accurate digital instrument for the measurement of circular polarisation of luminescence. J. Phys. E Sci. Instrum. 15, 945 (1982).
Schippers, P. H. & Dekkers, H. P. J. M. Direct determination of absolute circular dichroism data and calibration of commercial instruments. Anal. Chem. 53, 778–782 (1981).
Glover-Fischer, D. P. et al. Excited-state enantiomer interconversion kinetics probed by time-resolved chiroptical luminescence spectroscopy. The solvent and temperature dependence of Λ-Eu(dpa)33- ⇄ Δ-Eu(dpa)33- enantiomer interconversion rates in solution. Inorg. Chem. 37, 3026–3033 (1998).
Reid, M. F. Time-resolved circularly polarized luminescence as a probe of energy-transfer dynamics in rare-earth doped crystals. J. Lumin. 45, 384–386 (1990).
Zinna, F. & Di Bari, L. Lanthanide circularly polarized luminescence: bases and applications. Chirality 27, 1–13 (2015).
Furlan, F. et al. Chiral materials and mechanisms for circularly polarized light-emitting diodes. Nat. Photon. 18, 658–668 (2024).
Han, J. et al. Recent progress on circularly polarized luminescent materials for organic optoelectronic devices. Adv. Opt. Mater. 6, 1800538 (2018).
Baguenard, B. et al. Theoretical and experimental analysis of circularly polarized luminescence spectrophotometers for artifact-free measurements using a single CCD camera. Nat. Commun. 14, 1065 (2023).
Siegel, J. et al. Wide-field time-resolved fluorescence anisotropy imaging (TR-FAIM): imaging the rotational mobility of a fluorophore. Rev. Sci. Instrum. 74, 182–192 (2003).
Steinberg, I. Z. & Ehrenberg, B. A theoretical evaluation of the effect of photoselection on the measurement of the circular polarization of luminescence. J. Chem. Phys. 61, 3382–3386 (1974).
Bonsall, S. D., Houcheime, M., Straus, D. A. & Muller, G. Optical isomers of N,N′-bis(1-phenylethyl)-2,6-pyridinedicarboxamide coordinated to europium(III) ions as reliable circularly polarized luminescence calibration standards. Chem. Commun. 2007, 3676–3678 (2007).
Binnemans, K. Interpretation of europium(III) spectra. Coord. Chem. Rev. 295, 1–45 (2015).
Cui, M. et al. Two homochiral EuIII and SmIII enantiomeric pairs showing circularly polarized luminescence, photoluminescence and triboluminescence. Dalton Trans. 50, 1007–1018 (2021).
Hellwege, K. H. & Kahle, H. G. Spektrum und Struktur kristalliner Europiumsalze. Z. Physik 129, 85–103 (1951).
Brittain, H. G. & Richardson, F. S. Circularly polarized emission studies on the chiral nuclear magnetic resonance lanthanide shift reagent tris(3-trifluoroacetyl-d-camphorato)europium(III). J. Am. Chem. Soc. 98, 5858–5863 (1976).
Axe, J. D. Jr Radiative transition probabilities within 4fn configurations: the fluorescence spectrum of europium ethylsulfate. J. Chem. Phys. 39, 1154–1160 (1963).
Görller‐Walrand, C. & Godemont, J. MCD of the Eu3+ ion in aqueous solution. Analysis of the 5D0,1,2 ← 7F0,1,2 transitions. J. Chem. Phys. 67, 3655–3658 (1977).
Kaczkan, M., Kowalczyk, M., Szostak, S., Majchrowski, A. & Malinowski, M. Transition intensity analysis and emission properties of Eu3+:Bi2ZnOB2O6 acentric biaxial single crystal. Opt. Mater. 107, 110045 (2020).
Weissman, S. I. Intramolecular energy transfer the fluorescence of complexes of europium. J. Chem. Phys. 10, 214–217 (1942).
Crosby, G. A., Whan, R. E. & Freeman, J. J. Spectroscopic studies of rare earth chelates. J. Phys. Chem. 66, 2493–2499 (1962).
Chang, V. Y. et al. Photophysical and chiroptical properties of the enantiomers of N,N′-bis(1-phenylpropyl)-2,6-pyridinecarboxamide and their chiral 9-coordinate Ln3+ complexes. J. Org. Inorg. Chem. 2020, 3815–3828 (2020).
Klink, S. I., Hebbink, G. A., Alink, P. G. B. O., Veggel, F. C. J. M.van & Werts, M. H. V. Synergistic complexation of Eu3+ by a polydentate ligand and a bidentate antenna to obtain ternary complexes with high luminescence quantum yields. J. Phys. Chem. A 106, 3681–3689 (2002).
Li, X., Xie, Y. & Li, Z. The progress of circularly polarized luminescence in chiral purely organic materials. Adv. Photon. Res. 2, 2000136 (2021).
Frédéric, L. et al. Maximizing chiral perturbation on thermally activated delayed fluorescence emitters and elaboration of the first top-emission circularly polarized OLED. Adv. Funct. Mater. 30, 2004838 (2020).
Lakowicz, J. R. Principles of Fluorescence Spectroscopy (Springer, 2006).
Rice, S. A. & Kenney-Wallace, G. A. Time-resolved fluorescence depolarization studies of rotational relaxation in viscous media. Chem. Phys. 47, 161–170 (1980).
Hinckley, D. A., Seybold, P. G. & Borris, D. P. Solvatochromism and thermochromism of rhodamine solutions. Spectrochim. Acta A 42, 747–754 (1986).
Reponen, A.-P. M. et al. Dataset for broadband transient full-Stokes luminescence spectroscopy, Zenodo, https://doi.org/10.5281/zenodo.15360970 (2025).
Acknowledgements
We thank the Rowland Institute at Harvard, the Studienstiftung des deutschen Volkes and EPFL for providing funding. We acknowledge W. R. Kitzmann for discussions, K. O. Mastej for assistance with experimental work and the staff of the Rowland Institute at Harvard, in particular R. C. Stokes, for technical assistance. G.P. and L.E. thank D. Buisson for analytical support, and the doctoral school 2MIB and the French Ministry of Higher Education, Research and Innovation for funding.
Funding
Open access funding provided by EPFL Lausanne.
Author information
Authors and Affiliations
Contributions
A.-P.M.R. designed the project and experiments, built and validated the setup with help from M.M., prepared the solution samples with help from Z.A.V., performed all experiments except investigation of water-mixed DMSO solutions, analysed and interpreted the data, produced figures and wrote the paper. M.M. designed and wrote the software and automation algorithm, wrote the paper and performed experiments for investigation of water-mixed DMSO solutions with help from Z.A.V., who prepared solution samples. S.F. supervised the project. S.F. and Z.A.V. edited the paper. L.E. prepared powder samples of the chiral dye BPC under the supervision of G.P.
Corresponding author
Ethics declarations
Competing interests
A patent concerning the transient broadband sensitive full-Stokes vector setup reported here has been recently filed.
Peer review
Peer review information
Nature thanks Lorenzo Di Bari, Yutaka Okazaki and the other, anonymous, reviewer(s) for their contribution to the peer review of this work. Peer reviewer reports are available.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Extended data figures and tables
Supplementary information
Supplementary Information
This file contains Supplementary Text, Supplementary Figs., Supplementary Data, Practical Considerations for Measurements, Algorithms and Automation and Supplementary References.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Reponen, AP.M., Mattes, M., VanOrman, Z.A. et al. Broadband transient full-Stokes luminescence spectroscopy. Nature 643, 675–682 (2025). https://doi.org/10.1038/s41586-025-09197-3
Received:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/s41586-025-09197-3