Main

Precision measurements of the magnetic properties of simple systems stand as a powerful tool for investigating fundamental physics, enabling some of the most precise tests of symmetry violations. For instance, the experiments described in ref. 11 used a 3He/129Xe comagnetometer to place tight constraints on CPT-invariance-violating and Lorentz-invariance-violating parameters for neutrons12. Incoherent studies of the magnetic properties of single electrons13 provide unparalleled tests of the Standard Model, while also setting constraints on the parameter space in which the dark photon could exist14. Meanwhile, direct measurements on 3He+ and 9Be+ ions have established the most precise absolute magnetometers so far15 and test multi-electron shielding factors16. Our experiments focus on antimatter-based magnetometry17 using cryogenic multi-Penning-trap systems. We have measured the proton (p) magnetic moment with a fractional accuracy of 300 ppt (ref. 18) and determined that of the antiproton \((\bar{p})\) with 1.5 ppb resolution8. These experiments are based on incoherent spin-projection measurements using the continuous Stern–Gerlach effect19,20, combined with decoherent measurements of the Larmor νL and the cyclotron νc frequencies in the magnetic field B0 = 1.945 T of our PT (ref. 21). The ratio of the measured frequencies gives the gyromagnetic g-factor g/2 = νL/νc. Decoherent Larmor resonance spectroscopy results in suppressed spin inversion and contributes to the broadening of the measured resonance lines, both of which diminish measurement resolution. Establishing coherent techniques to overcome these limitations is an exciting prospect and represents a key advancement towards establishing nuclear magnetic moment measurements at substantially improved resolution.

Here we demonstrate the coherent quantum transition spectroscopy of a single nuclear spin 1/2 particle—a single trapped antiproton. The measurements are carried out in the multi-Penning-trap system of the BASE collaboration17 at the Antiproton Decelerator (AD)/ELENA facility of CERN. By applying our unique two-particles/three-traps technique8, supported by our cooling trap (CT)22, we observe Rabi oscillations of a single \(\bar{p}\) spin and achieve spin coherence times greater than 50 s. In line-shape scans, in which we vary an applied spin-flip radiofrequency νrf with respect to the Larmor frequency \({\nu }_{{\rm{L}}}=\left(\frac{{g}_{\bar{p}}}{2}\right)\times {\nu }_{{\rm{c}}}\), we obtain spin inversions greater than 70% and a full width at half maximum (FWHM) of the spin-transition resonance that is below 200 mHz. This is more than ten times narrower than in our previous antiproton magnetic moment measurements8. We show that the FWHM is, at present, limited by decoherence induced by cyclotron frequency measurement noise. This is a crucial step towards improved measurements of the p and \(\bar{p}\) magnetic moments with a fractional accuracy less than 100 ppt and will allow for searches of time signatures of asymmetric antimatter/dark matter coupling23 at improved mass resolution and increased data-taking rate, thanks to the higher signal-to-noise ratio and smaller FWHM of the coherent measurements.

The heart of our experiment is a superconducting solenoid magnet with a horizontal bore, operated at a magnetic field of B0,PT = 1.945 T. Inside the bore, the cryogenic multi-Penning-trap system, shown in Fig. 1, is mounted. Most important for this study are the AT, in which the continuous Stern–Gerlach effect is applied19, the homogeneous PT, in which precision frequency measurements take place, and a park trap (PKT). AT and PT centres are separated by 73.4 mm and PT and PKT centres are separated by 18.6 mm. The trap stack is placed inside a cylindrical hermetically sealed, pinched, cryo-pumped vacuum chamber, in which pressures less than 1018 mbar and (anti)particle storage times of years are achieved24. The trap electrodes, designed as in ref. 25, are primarily made out of gold-plated copper. The central ring electrode of the AT is made of ferromagnetic CoFe, also gold-plated, which distorts the magnetic field in the centre of the trap to BAT(z) = B0,AT + B2,AT × (z − zAT,0)2, in which B0,AT = 1.231 T, B2,AT = 266(5) kT m2 and zAT,0 is the trap centre (Fig. 1a). The magnetic field in the centre of the PT is BPT(z) = B0,PT + B1,PT × (z − zPT,0) + B2,PT × (z − zPT,0)2, with zPT,0 being the centre of the trap. Achieved with a local persistent magnet system, the coefficient B2,PT can be tuned in a range of about ±350 mT m2. The gradient field B1,PT can be adjusted in a range between 10 mT m−1 and 24 mT m−1. Also part of the magnet system is a set of self-shielding solenoids26,27, with a shielding factor greater than 50. The trap electrodes are biased with ultrastable voltage sources. The applied voltages are selected such that, in the trap centres, homogeneous quadrupolar potentials Φ(z, ρ) = V0C2(z2 − ρ2/2) are formed25. Here V0 is the voltage applied to the central ring electrode, C2 is a geometry coefficient (Extended Data Table 1 and Methods) and z and ρ are cylindrical coordinates, for which z points along the magnetic field axis. A single particle in such crossed static fields oscillates at three independent frequencies28, at the modified cyclotron frequency ν+,PT ≈ 29.645 MHz, the axial frequency νz,PT ≈ 637 kHz and the magnetron frequency ν,PT ≈ 7 kHz. An invariance theorem \({\nu }_{{\rm{c}}}^{2}={\nu }_{+}^{2}+{\nu }_{z}^{2}+{\nu }_{-}^{2}\) (ref. 28) relates the free cyclotron frequency νc = (qB0)/(2πm) to ν+, νz and ν; here q and m are the charge and the mass of the single trapped particle, respectively. Details on the eigenfrequencies and their measurements using non-destructive detection (see Fig. 1b) are described in Methods and summarized in Extended Data Tables 1 and 2.

Fig. 1: Experimental set-up.
figure 1

a, Multi-Penning trap to demonstrate coherent spin quantum transitions with a single trapped antiproton. The trap stack consists of an antiproton reservoir trap, a park trap, a highly homogeneous and shielded precision trap, an analysis trap to apply the continuous Stern–Gerlach effect and a trap to cool the antiproton’s modified cyclotron mode. The trap electrodes (golden) are spaced by sapphire rings (blue shading). b, Schematic of a single-particle detection system. The detector is represented by a parallel RLC circuit, with inductance L ≈ 2 mH, capacitance Cp ≈ 25 pF and Rp ≈ 150 MΩ. c, Magnetic bottle strength in the centre of the precision trap, as a function of current applied to the persistent local superconducting magnet. Error bars are smaller than the size of the data points. d, Non-destructive detection of spin transitions in the centre of the analysis trap by measuring the axial frequency of the single trapped antiproton. Each frequency measurement takes around 120 s.

To implement the coherent spin transition spectroscopy, we use the two-particles/three-traps technique described in ref. 8. The measurement protocol is shown in Fig. 2. First, we initialize the spin state of a cold ‘Larmor’ particle in the AT. A second antiproton, the ‘cyclotron’ particle, is prepared in the PT for high-precision νc,PT measurements to determine the magnetic field of the trap29. After initialization, the Larmor particle is transported to the PT, at which a spin-flip drive is applied. The particle is then returned to the AT to determine whether a spin transition has occurred.

Fig. 2: Measurement protocol.
figure 2

Illustration of the experiment sequence described in the text.

To begin, we first use the magnetic shimming system (Fig. 1a,c) and use measurements with the cyclotron particle to tune the magnetic coefficient B2,PT. In the case of finite B2,PT, interaction of the particle with the axial detector causes axial rms-amplitude fluctuations \(\propto ({k}_{{\rm{B}}}{T}_{z}/\)\(m{\omega }_{z}^{2})\). These shift the Larmor frequency by \({\Delta \nu }_{{\rm{L}}}=(1/{4{\rm{\pi }}}^{2})({\nu }_{{\rm{L}}}/{\nu }_{z}^{2})({B}_{2}/{B}_{0})({k}_{{\rm{B}}}{T}_{z}/m)\) with the particle-to-detector correlation time of about 100 ms, causing motional spin decoherence. We thus tune B2,PT = 1.2(1.8) mT m2, corresponding at the temperature Tz,PT = 8.5(3) K of the PT axial detector to spin coherence times longer than 1 h (ref. 28). Next, we apply the cooling protocol described in ref. 22 to the Larmor particle and cool it to a cyclotron energy E+/kB = T+ < 100 mK. Owing to the presence of the strong magnetic bottle B2,AT, a spin transition induces an axial frequency shift of Δνz,SF = 173(1) mHz (ref. 19). A sequence of axial frequency measurements νz,AT interleaved by spin transitions is shown in Fig. 1d.

To initialize the spin state of the Larmor particle, we apply a sequence of νz,AT measurements, each taking 120 s, followed by a 10 s injection of a magnetic spin-flip drive at νrf,AT = 51.651 MHz. At the background νz,AT scatter10 Ξback,AT ≈ 32(2) mHz achieved in this trap, we identify a measured νz,AT difference Δνz,SF > 140 mHz as a spin transition. This leads to spin-state initialization with a confidence of about 100%. Subsequently, we use the cyclotron particle in the PT to determine B0,PT in this trap. To that end, we measure νc,PT, using the technique described in ref. 29. A single cyclotron frequency measurement of approximately 180 s resolves νc with a fractional uncertainty of σ(νc,PT)/νc,PT = 1.42(7) ppb. This frequency defines the radiofrequency that is irradiated to later induce the coherent spin transitions in the PT νrf,SF,PT = (gp/2) ×νc,PT, in which gp/2 = 2.7928473441 is used8. Next, we move the cyclotron particle to the PKT centre and the Larmor particle from the AT to the PT, by applying voltage ramps to the transport electrodes that interconnect the traps. Then a spin-flip drive at νrf,PT is irradiated for a time tSF,PT, transmitted by a coil mounted close to the PT (Fig. 1a). Afterwards, we move the Larmor particle back to the AT and the cyclotron particle to the PT and cool its magnetron mode. To identify whether the spin in the PT was flipped, we record a subsequent νz,AT/spin flip sequence to compare the spin state in which the particle was leaving the AT and once it returns from the PT. Here we identify a measured νz jump of Δνz > Δνz,SF/2 = 0.173/2 Hz as a detected spin transition21. The error rate of identifying the spin flips driven in the PT depends on the axial frequency scatter of the νz,AT sequences; the formalism to correctly estimate the error rate is described in refs. 30,31. The median axial frequency scatter of 32(2) mHz corresponds to an error rate less than 5%.

By applying this protocol and adjusting the radiofrequency interrogation time tSF,PT to drive spin transitions in the PT, we repeat the procedure 20 times for each value of tSF,PT, thereby obtaining the spin-flip probability P(tSF,PT), shown as the blue data points in Fig. 3. This corresponds to the first observation of Rabi oscillations with a single nuclear spin 1/2 antiparticle. The red line is a Monte Carlo fit (Methods and Extended Data Table 3) of

$$L({\varOmega }_{0},\Delta ,t)={\int }_{-\infty }^{\infty }{P}_{{\rm{SF,PT}}}({\varOmega }_{0},\Delta +\sigma ,t)G(\sigma \,;\mu ,\sigma ){\rm{d}}\sigma ,$$

in which the function

$${P}_{{\rm{SF,PT}}}({\varOmega }_{0},\Delta ,t)=\frac{{\varOmega }_{0}^{2}}{{\varOmega }_{0}^{2}+{\Delta }^{2}}\times {\sin }^{2}({\rm{\pi }}\sqrt{{\varOmega }_{0}^{2}+{\Delta }^{2}}\times t),$$

is the spin-flip probability with Rabi frequency Ω0, detuning Δ = νrf,PT − νL and interrogation time t. The function G(µ, σ) is a Gaussian distribution, defined by the scatter σ ≈ 52 mHz, arising from the νc,PT measurement noise present during these experiments. This noise leads to an observed decay of spin inversion, to which an effective spin coherence time of τs,PT = 50.2(4.8) s can be assigned. For further details on the analysis, see Methods. This indicates that, in an optimized Rabi resonance scan, executed on the π-pulse, a FWHM ΔνFWHM ≈ 20 mHz or 250 ppt could be achieved. We note that magnetic noise imposed by the accelerator reduces the spin coherence time to 5.6(4) s (Extended Data Fig. 1).

Fig. 3: Antiproton Rabi oscillations.
figure 3

Observation of coherent Rabi oscillations of the spin of a single trapped antiproton. The blue points represent the measured data and the red line depicts a Monte Carlo fit, which assumes 52 mHz cyclotron frequency measurement decoherence as determined in the related measurements. In grey are the uncertainties of the Monte Carlo simulation. The effective coherence time is τs,PT = 50.2(4) s. Each point is an average of 20 spin flip attempts, uncertainty bars represent the standard deviations of the measured data distributions. Throughout the measurement campaign we have recorded several of these plots for different Rabi frequencies.

To optimize the spectral response of the coherent dynamics for measurements at optimum line-centre resolution, we first record Rabi oscillations at different drive amplitudes and determine the tSF,PT in the PT at which maximum inversion is achieved. At the determined optimum tSF,PT, we perform Larmor resonance scans, keeping tSF,PT constant while scanning the frequency νrf,PT of the spin-flip drive with respect to νL = (g/2) × νc,PT. Here νc,PT is obtained with the cyclotron particle in the PT, extracted from a sequence of six frequency measurements, taken before the application of the spin-flip drive. To resolve the resonance, we sample ten points per irradiated νrf,PT and scan each resonance with a minimum amount of eight discrete frequency offsets, which typically takes 60 h. The recorded cyclotron frequency sequence allows us to study ΔνFWHM and the inversion S as a function of νc,PT averages used to reconstruct νL at the time when the spin-flip drive is applied in the PT. Averaging several magnetic field measurements for the νL reconstruction decreases the cyclotron frequency scatter σc,PT to about 30 mHz, which narrows the width of the Larmor resonance while increasing the inversion. This is shown in Fig. 4a, in which we plot the ratio of inversion S [0, 1] over the measured ΔνFWHM as a function of the Rabi frequency Ω0/(2π) applied to sampled spin resonances. The purple data points are for one νc,PT measurement and the blue points are for four averages that are used to extrapolate νL. The grey lines represent the calculated scalings for different cyclotron frequency fluctuations between σ = 30 and 100 mHz. More than four νc,PT averages, due to a random walk in the field of the superconducting magnet, adds further fluctuation, broadening the Larmor resonance line again.

Fig. 4: Antiproton spin resonance.
figure 4

a, Signal SνFWHM for different Rabi frequencies and σc,PT. The grey lines are calculated results for σc,PT = 30, 40, 60, 80 and 100 mHz. b, Measured coherent νL resonance at the optimized parameters found in the experiment, blue scatters and best least-squares fit of a Voigt profile to the data (solid red line). The grey data points are from the previously measured antiproton g-factor resonance8. The coherent line has 1.54 times higher signal-to-noise ratio and a FWHM (green vertical lines) that is about 16 times narrower than the width in ref. 8. For both plots, the uncertainty bars represent the standard deviations of the measured data distributions.

By systematically scanning the interrogation times and Rabi frequencies, we obtain at Ω0/(2π) ≈ 50 mHz and a drive time of 16 s a signal inversion of 0.77(4) at ΔνFWHM = 156(4) mHz, as shown in Fig. 4b. The blue data points represent the measurement described here and the red line is a fit of a Voigt profile. Compared with the previous most precise measurement of the antiproton magnetic moment8 (grey data in Fig. 4b), this corresponds to an increase of the inversion by a factor of 1.54 at a 16-fold reduction of the FWHM of the resonance line. The line-centre determination of the dataset is at a level of 12 mHz or 150 ppt statistical uncertainty, ten times more accurate than in ref. 8. Note that this resonance was sampled during a data-taking period of only about 60 h, whereas the data accumulation in our previous measurement took place over a period of two months.

The statistical uncertainty in determining the line centre of such g-factor resonances scales proportionally to ΔνFWHM/S. Consequently, on the basis of our coherent spin spectroscopy data, we infer that, under present experimental conditions—relative to those reported in ref. 8—an approximately 25-fold improvement in the statistical precision of the g-factor line-centre determination is achievable. However, the two-particle method introduces systematic limitations on the interpretation of the measured line centre. Specifically, the transfer of particles between the AT and the PT induces magnetic field variations and voltage settling drifts. These effects undermine the critical assumption that the magnetic field remains constant between the νc,PT measurements and the application of the Larmor drive—a requirement for the precise determination of the antiproton magnetic moment. Quantifying the complete systematic uncertainty budget within the limited three-month annual shutdown of the accelerator remains a substantial challenge. Because accelerator operation reduces the spin coherence time by nearly an order of magnitude, systematic shifts during on and off periods differ. Although using a single-particle double-trap technique21 could mitigate the present systematic uncertainties, this approach would substantially extend the required data acquisition time—beyond what is feasible during the short shutdown windows. To address these limitations, we have developed the transportable antiproton trap BASE-STEP32, enabling the relocation of antiprotons to dedicated, quiet laboratory environments at HHU Düsseldorf and CERN. These facilities will host precision experiments not exposed to accelerator-induced magnetic field fluctuations. By combining coherent spin quantum spectroscopy with phase-coherent cyclotron frequency measurements in such an environment, it will become feasible to suppress magnetic field noise by at least a factor of five. This would allow statistical resolutions of the g-factor line centre at the level of approximately 10 ppt. The application of these techniques to the proton would open the path towards one of the most stringent tests of CPT invariance in the baryon sector12.

Methods

Penning-trap frequencies

A Penning trap is a superposition of a strong magnetic field, for BASE B0 = 1.945 T and electrostatic potential ϕ = V0C2(z2 − ρ2/2). Here z and ρ are cylindrical coordinates, the z-axis is defined by the magnetic field axis and z = 0 is the centre of the central ring electrode of the trap. The voltage V0 is applied to the central ring electrode of the five-electrode traps25 used and C2 is a trap-specific geometry coefficient, related to the size of the trap electrodes. In magnetic field B0, a particle of charge q and mass m is oscillating at the free cyclotron frequency

$${\nu }_{{\rm{c}}}=\frac{1}{2{\rm{\pi }}}\frac{q}{m}B.$$

The electrostatic potential confines the particle in the axial direction, leading to an axial oscillation along the magnetic field lines at

$${\nu }_{z}=\frac{1}{2{\rm{\pi }}}\sqrt{\frac{2q{C}_{2}{V}_{0}}{m}}.$$

The potential also modifies the cyclotron frequency to the modified cyclotron frequency ν+. Also, the crossed magnetic and electric field leads to a slow drift at the magnetron frequency ν, both modes oscillating perpendicular to the magnetic field lines at

$${\nu }_{+}=\frac{1}{2}({\nu }_{{\rm{c}}}+\sqrt{{\nu }_{{\rm{c}}}^{2}-2{\nu }_{z}^{2}})$$

and

$${\nu }_{-}=\frac{1}{2}({\nu }_{{\rm{c}}}-\sqrt{{\nu }_{{\rm{c}}}^{2}-2{\nu }_{z}^{2}}).$$

The most relevant parameters of the AT and the PT are summarized in Extended Data Table 1.

Image current detectors

The particle frequencies ν+, νz and ν are measured by image current detection33. A schematic illustrating the working principle of such a detector is shown in Fig. 1b. The concept is that a superconducting inductor L is connected to one of the trap electrodes. Together with the capacitance Cp of the trap, it forms a parallel tuned circuit that acts at its resonance frequency νr as an effective parallel resistance Rp = 2πνrQL, in which Q is the quality factor of the tuned circuit. The particle-induced image current (for example, axial oscillation)

$${i}_{{\rm{p}}}=\frac{q}{{D}_{z}}(2{\rm{\pi }}{\nu }_{z,{\rm{p}}})z$$

then induces a voltage drop

$${u}_{{\rm{p}}}={R}_{{\rm{p}}}\times {i}_{{\rm{p}}}={R}_{{\rm{p}}}\times \frac{q}{{D}_{z}}(2{\rm{\pi }}{\nu }_{z,{\rm{p}}})z.$$

Here the parameter D ≈ 0.01 m is the effective electrode distance, which depends on the trap geometry and the distance to the pickup electrode to which the detector is connected (Extended Data Table 2).

Sensitivity

For the detector resistances of typically Rp ≈ 100 MΩ and the thermal noise of \({e}_{{\rm{n}}}\approx \sqrt{4{k}_{{\rm{B}}}{T}_{z}{R}_{{\rm{p}}}}\), the top noise level of the detector at its resonance frequency νr, it is possible to detect a particle at an oscillation amplitude of about 100 µm, inducing an image current of about 10 fA.

Owing to the particle–detector interaction, once the particle frequency νz,p is tuned to νr, excited particles are damped with a cooling time constant

$${\tau }_{{\rm{p}}}=\frac{m}{2{\rm{\pi }}{\nu }_{{\rm{r}}}QL}\frac{{D}^{2}}{{q}^{2}}\,.$$

A particle in thermal equilibrium with the detector shorts the detector’s thermal Johnson noise and appears as a dip at its axial frequency νz on the measured noise spectrum29. The FWHM of the dip is proportional to the damping Δνz = 1/(2πτp). This ‘dip detection’ technique—in which we determine νz by fitting a function to the measured detector noise spectra—is used for the axial frequency measurements in the AT as well as for the cyclotron frequency measurements in the PT, as discussed in detail in ref. 29.

Recent experiment upgrades

In comparison with our previous measurement of the antiproton magnetic moment30, the experimental set-up has undergone a comprehensive upgrade, resulting in notable performance gains. Key enhancements include a complete overhaul of the cryogenic electronics: the cyclotron and axial detection systems have been improved, the frequency tuning range of the cyclotron detectors has been extended and the cryogenic filtering and switching stages have been optimized. Moreover, the implementation of a dedicated cooling trap22 has led to a substantial increase of cold-particle preparation time.

Further stability has been achieved by reengineering the cryogenic trap inlay and integrating a magnetic tuning and self-shielding system, ensuring precise magnetic field control and long-term operational reliability. Together, these developments enable higher experimental throughput, faster particle preparation and faster and more robust data acquisition.

These technical advancements directly translate into improved control over the spin degree of freedom. Spin-state initialization now reaches fidelities of F ≈ 100%, whereas quantum projection measurements of spin flips in the PT consistently achieve fidelities exceeding 95% (ref. 22).

Simulated likelihood estimation of Rabi oscillations

When applying a spin-flip drive in the PT, we define the frequency νrf to drive the spin transitions based on the cyclotron frequency measurements executed with the cyclotron particle in the PT. The used double-dip frequency measurement method, explained in detail in ref. 29, has an intrinsic frequency fluctuation σc,PT(t) that depends on the frequency measurement time. For short frequency averaging time, the fluctuation of the determined νc,PT is dominated by thermal-noise fluctuations of the frequency spectrum; for very long frequency averaging times, the magnetic field of our superconducting magnet is drifting away. At the optimum frequency averaging time of about 540 s, we obtain a frequency fluctuation of σc,PT(t)/νc,PT ≈ 800 ppt. To understand our data, which evolve under both deterministic laws and random influences, we use Monte Carlo simulations and model the experiment protocol described in the main text, in which we execute for one particular interrogation time tSF,PT a total of 20 spin-flip experiments at drive frequency νrf that is defined by \(({g}_{\bar{p}}/2)\times {\nu }_{{\rm{c,PT}}}\). Note that the fluctuation σc,PT limits our ability to irradiate the exact on-resonant νrf = νL, which effectively leads to a convolution of the time-dependent spin dynamics PSF,PT(Ω0, Δ, t) given in the main manuscript with the frequency measurement fluctuation σc,PT. Our measured results are mean values of PSF,PT(Ω0, Δ, t) for different values of the detuning parameter Δ that is noised by the measurement fluctuation σc,PT.

To evaluate the data, we use a simulated maximum likelihood method. We first simulate the influence of measurement noise using a Mersenne Twister pseudo-random number generator to model the distribution of σc,PT fluctuations. These are used to generate a set of randomly detuned spin-flip responses PSF,PT(Ω0, Δ, t), whose averages are calculated. We estimate the likelihood L of the data by averaging over the simulated likelihoods and applying a Nelder–Mead algorithm to maximize it to find the best-fit parameters. The confidence intervals on the fit parameters θk are obtained by evaluating l(θ) = log(L(θ)) and numerically solving \(-2(l(\theta )-l(\widehat{\theta }))=1\), in which \(\widehat{\theta }\) is the parameter value that maximizes the likelihood. The red line in Fig. 3 represents the optimized average result obtained by this algorithm and the grey-shaded area represents the results of 10,000 simulations for different random detuning parameters Δ.

Finally, the effective spin coherence time is extracted by fitting an exponentially damped oscillator to the average outcome of the Monte Carlo simulations optimized through this likelihood analysis. The results of the best fit are summarized in Extended Data Table 3.

Rabi oscillations with the accelerator on

The experiments were conducted in the AD/ELENA antimatter facility of CERN. The magnetic ramps of the antiproton decelerator magnets running in the background induce magnetic field fluctuations with amplitudes on the 1.6 µT level, which reduce the spin coherence time to 5.4(6) s, as shown in Extended Data Fig. 1.

Ethics Statement

Our work values diverse perspectives, promotes diversity and upholds the highest standards of integrity in research and communication. We strive to ensure that science serves the global community responsibly.