Abstract
Positron Emission Tomography (PET) with 2-deoxy-2-[18F]fluoro-D-glucose (FDG) and Computed Tomography (CT) are key tools in oncology diagnostics. However, most PET studies focus on tumour detection. We propose that a holistic assessment of the macroenvironment using FDG-PET could enhance our understanding of systemic treatment interactions and improve patient care. To achieve this, we aim to develop a normative database for FDG-PET based on healthy controls, providing a reference for identifying voxel-level metabolic aberrations in cancer patients. This approach may uncover treatment-related changes beyond cancer diagnostics. 48 healthy controls who underwent dynamic test-retest whole-body PET/CT imaging post [18F]FDG injection were included in this cohort. Static PET images (57–62 min post-injection) were reconstructed using CT-based attenuation and scatter correction, with iterative reconstruction incorporating resolution recovery and time-of-flight data. Standardized uptake values (SUVs), tissue densities (HU), and volumes for 135 organs were calculated using in-house segmentation software. The dataset, including anonymized PET/CT images and CT-derived segmentations in NIfTI format, supports the creation of a normative FDG-PET database and enables multi-organ analyses using PET/CT imaging.
Background & Summary
The global incidence and prevalence of complex diseases — such as cancer, cardiovascular disorders, neurodegenerative conditions, and metabolic syndromes — have risen steadily in recent years1,2,3. Early diagnosis and the implementation of personalized treatment strategies are essential for improving patient outcomes, including survival rates and quality of life. To this end, diagnostic tools, particularly blood-based biomarkers and non-invasive imaging techniques, play a pivotal role.
Non-invasive anatomical imaging techniques, such as Computed Tomography (CT), provide high spatial resolution for visualizing patient anatomy and pathomorphology. In contrast, functional imaging methods, like Positron Emission Tomography (PET), offer molecular-level insights with high specificity through the use of targeted radiotracers. Together, these imaging modalities—CT and PET—deliver complementary visual and quantitative data that are often indispensable for guiding treatment decisions.
The integration of PET and CT into a dual-modality PET/CT system has demonstrated exceptional sensitivity and specificity in detecting and characterizing malignant diseases4. Moreover, PET/CT imaging has proven invaluable for enhancing diagnosis, monitoring disease progression, and predicting therapeutic responses across a broad spectrum of cancer patients5.
Today, over 80% of all PET scans are conducted for oncology indications, utilizing 2-deoxy-2-[18F]fluoro-D-glucose (FDG) as the tracer of choice. FDG highlights regions of increased glucose metabolism, a hallmark of cancer tissue. Whole-body PET (WB-PET) imaging, which scans the entire patient, is commonly employed for this purpose6,7. Metastatic lesions are identified on WB-PET scans by detecting abnormally elevated local FDG accumulations, visualized in three-dimensional representations of the patient’s anatomy.
This approach—relying on hypermetabolic uptake patterns in FDG-PET images—is widely used in oncology diagnostics8. However, it underutilizes the full potential of PET imaging. Current analytical methods often treat each organ as an isolated entity, overlooking the intricate metabolic interactions between organs9. This reductionist perspective is particularly limiting when assessing systemic diseases, such as chronic conditions, which disrupt metabolic homeostasis and affect multiple organs simultaneously through disease-specific networks10.
In addition to identifying pathological aberrations, including tumours, heart disease11, and neurodegenerative disorders12, FDG-PET imaging has also emerged as the method of choice for assessing whole-body metabolic health13. Prior studies of FDG uptake in patients already hinted at the value of physiological FDG uptake in normal tissues throughout the body as an “adjunct to physician experience” that comes with “the potential to improve interpretive accuracy”14. Today, WB- FDG-PET scans may add crucial information on “normal” tracer uptake patterns, offering a systemic perspective on inter-organ metabolic networks9.
Detecting associated variations in FDG accumulation across multiple organs differs fundamentally from tumour lesion-based detections8, and is often challenging for a single observer studying a single patient, relying solely on visual assessments. Therefore, the establishment of a normative atlas of FDG-PET information, together with the provision of automated and AI-supported methods, may assist in evaluating these systemic effects by enabling the detection of subtle metabolic deviations that precede overt disease manifestation, such as in the early stages of cachexia15.
Nonetheless, publicly available imaging databases remain scarce in their representation of PET data of healthy controls. The AutoPET challenge provides open access to 1014 whole-body FDG-PET/CT image sets. However, this database does not include true healthy controls, but FDG-PET negative scans of cancer patients16. Two other community efforts provide open access to PET data, but do not entail WB-PET images of healthy controls17,18. Still, the value and results of open-sourcing PET-based datasets can already be appreciated19. The Cancer Imaging Archive (TCIA) hosts a variety of imaging datasets, but only one such dataset has been obtained from healthy controls who underwent low-dose CT imaging alone20.
As part of our ENHANCE.PET initiative21, we curated FDG-PET/CT datasets of healthy controls (subjects) who underwent two PET/CT scans in a test-retest setting (hereafter referred to as Test and Retest) with a one-month interval between them. Each dataset (Test and Retest) includes 48 whole-body PET/CT scans following the injection of 100 MBq of FDG and a 62-minute dynamic emission scan, along with corresponding low-dose CT images acquired for the purpose of CT-based attenuation (and scatter) correction22,23,24. In addition, we provide the organ-based segmentations of 135 healthy tissues per scan, incorporating both CT and PET readouts. The segmentations were generated using our in-house tool, MOOSE version 3.0.1325. The dataset is provided in anonymized NIfTI format - with PET and CT images being defaced - to ensure subject privacy, along with demographic details and CT and PET acquisition parameters as non-imaging metadata.
It is understood that FDG uptake is influenced by a number of confounders26, including age27,28, body mass index29,30, sex31, ethnicity32, and physical activity levels of subjects33,34. Within our original project, we seek to build a normative atlas of glucose uptake - as measured by WB-FDG-PET - across multiple organs in Caucasian controls. In addition, we intend to study the reproducibility and repeatability of FDG-PET readouts in this healthy control cohort so as to define a baseline against which disease-induced metabolic aberrations (in similar cohorts) can be evaluated.
As detailed in the Technical Validation Section, this dataset is well-suited for establishing reliable reference values for FDG uptake in healthy controls (Caucasian, see ethnicity as a confounder). It also enables further validation of glycolytic activity across organs as a potential surrogate marker for systemic metabolic alterations induced by cancer, contingent on the analysis of confounder-matched cancer cohorts. This initiative aligns with our overarching goal of advancing healthcare by extending beyond a cancer-centric focus to offer a holistic perspective on disease diagnosis and management. By doing so, it enhances our understanding of health and disease at a broader, more systemic level.
We believe that making this standardized dataset - though limited in size - openly available will significantly contribute to the differential understanding of healthy and pathological tissues in computational medicine. By providing a comprehensive resource, we aim to facilitate future research and advanced data analysis in PET/CT imaging, particularly in areas such as multi-modal imaging analysis and the development and validation of deep learning algorithms.
Methods
Data collection
This dataset includes WB-FDG-PET/CT imaging data and subsequently derived CT and PET readouts for 135 organs of 48 healthy controls: 25 (52%) females and 23 (48%) males. All subjects were adults with a mean age of 38 ± 14 years (range: 19–59 y/o). The status of health, i.e., “healthy”, was defined as the known absence of systemic diseases, such as cancer or diabetes, as verified during the recruitment and initial subject consultation.
All verified healthy controls were included in a 6-month study (Fig. 1). Clinical tests for stress markers (hair, blood), inflammatory and other biochemical markers (blood) were performed four times throughout the study period: on day 1, the day of the Test PET/CT scan, the day of the Retest PET/CT scan, and again on the last day of the study. The time between the Test and the Retest PET/CT was 4-5 weeks. All subjects were given a wearable device (Garmin Forerunner 955) on day 1 and asked to wear it continuously throughout the entire study period to document biosignals against which any variations in the metabolic patterns seen on the FDG-PET images of the Test and Retest scan will be compared at a later time.
Healthy control study protocol: Recruited subjects were enrolled on day 1 for a clinical assessment, incl. blood parameters and stress markers (“Initiation”). On that day, subjects were given the smartwatch and instructed to wear it continuously throughout the entire study period. After ~5 weeks (day ~35), subjects were invited to the 1st PET/CT scan (Test) and the collection of blood and stress markers. After 4-5 weeks (day ~70), the same procedure (Retest) was repeated, and subjects were released for continuous wearable monitoring. After ~100 days, the subjects were called in for their clinical assessment, incl. blood parameters and stress markers (“Release”). Also, all subjects handed over their smartwatch, and their bio readouts were extracted and anonymized to be stored locally on-site.
All datasets were acquired in accordance with the Declaration of Helsinki, with written informed consent obtained from all subjects prior to examinations. All data were acquired between Sep 28, 2023, and Aug 5, 2024, at the Medical University of Vienna, Austria, following IRB approval (EK 1707/2022), which can also be found in the public registry of approved studies of the IRB: https://ekmeduniwien.at/core/catalog/2023/. The demographics of the study participants – recruited via the University network and adverts in cooperating institutions - are summarized in Table S1, and an overview is presented in Fig. 2.
Of note, this study was approved for the enrollment of 50 healthy controls. After the completion of the first FDG-PET/CT scan (Test, Fig. 1), 2/50 controls presented with incidental findings indicative of malignant disease. Following the bioptic confirmation of the image-based findings, both subjects were excluded from the study and transferred to standard clinical workup.
Imaging protocol
PET/CT imaging was conducted using a Biograph Vision QUADRA system (Siemens Healthineers, USA) with software version VR20B. This system integrates a 128-slice dual-energy CT alongside a PET component comprising four VISION PET units35. The system offers a 106 cm axial field of view (FOV), with a transverse and axial spatial resolution of 3.3 mm and 3.8 mm, respectively, at a 1 cm FOV offset. It achieves a sensitivity of 180 kcps/MBq with a peak NEC of 276 kcps at 25 kBq/mL. For detailed technical specifications and performance parameters, refer to36,37,38. To ensure the reliability of quantitative measurements, daily quality control procedures are performed for both PET and CT components, along with regular cross-calibration checks, conducted at least every six months and additionally following any changes to the imaging systems or dose calibrators.
Prior to the Test and Retest PET/CT scan, all subjects were asked to fast for 4 hours (blood glucose level < 150 mg/dL). Subjects were positioned head-first in a supine position with arms down and asked to lie still with the permission to breathe normally (shallow) during the duration of the examination (CT and PET for Test and Retest). A low-dose spiral CT scan of the entire imaging range with an automatic tube current modulation set at 25 mA reference and a tube voltage of 140 kVp using the zinc filter and quality setting 3 was performed first. The scanning parameters included a table feed per rotation of 38 mm and a spiral pitch factor of 1.0. Reconstruction was done using the iterative reconstruction algorithm ADMIRE and using the convolutional kernel Br32f and a reconstruction diameter of 780 mm. The reconstructed images had a pixel spacing of 1.523 mm × 1.523 mm, with a slice thickness of 2 mm. The corresponding matrix size was 512 × 512 × 531 voxels.
Following the completion of the CT scan, subjects were moved to the PET imaging position and injected with 100 MBq [18F]FDG. The PET emission scan was set to start immediately, and listmode emission data were acquired for 62 min. At the end of the examination, the subjects were released and asked to void. The total effective dose received by the participating subjects was estimated to be 3.0 mSv, with 33% from the LD-CT and 67% from the emission scan.
PET image data were reconstructed for 57–62 min post-injection using OP-OSEM with TOF information and PSF correction with 4 iterations and 5 subsets. A matrix size of 440 × 440 × 531 voxels with an in-plane voxel spacing of 1.65 mm × 1.65 mm and a slice thickness of 2 mm was used, and a Gaussian post-reconstruction filter of 2 mm full width at half maximum (FWHM) was applied. All standard corrections were utilized, comprising of CT-based attenuation and scatter correction, as well as corrections for randoms, decay, and dead time.
CT and PET reconstruction of all healthy subjects shared in this cohort resulted in 48 PET image volumes matched to 48 CT image sets at two time points along the study trajectory (Fig. 1: Test and Retest). Both PET/CT imaging sessions were set apart by an average of (38 ± 10) days (minimum: 22 days, maximum: 98 days, Table S1). All PET images were converted from Bq/mL to weight-based standardized uptake values (SUV). See Table S1 for details on key protocol parameters and reported scan and subject differences between Test and Retest.
Data processing, image segmentation, and readouts
All 50 participants of this study had their PET/CT examinations reviewed by a board-certified nuclear medicine physician for image quality assessment and incidental findings. As stated, 2/50 enrolled subjects were excluded from this study after confirming their incidental findings on the Test PET/CT (Fig. 1). The acquired PET and CT images of the remaining healthy controls (n = 48) were deemed of sufficiently high quality and free of detrimental artifacts. The images were segmented using the in-house developed and released MOOSE software version 3.0.1325, which was trained on a cohort of 1683 individual cases39, not including the presented cohort. For each subject and dataset (Test, Retest), MOOSE was used to automatically delineate 135 organs from the CT images. Since the CT and PET images were reconstructed with different voxel and matrix sizes, any CT-based multi-organ segmentation mask must be resampled – using a nearest-neighbor interpolation – to match the PET voxel and matrix sizes before extracting complementary regional PET and CT image quantification. Of note, prior to resampling, no additional PET-CT registration was performed for the combined PET/CT data.
In total, 11 biometric parameters were retrieved from both the PET and CT images per organ and subject. These parameters included: six parameters from the CT image (mean, standard deviation (STD), median, minimum, maximum tissue densities in HU, and organ volume), and five corresponding regional values from the matching PET images (mean, STD, median, minimum, and maximum SUV). We evaluated the mean and STD across the 48 subjects at Test and Retest (Fig. 1) as estimates of the normative, cohort-specific organ parameters at both time points. All data processing and metric extraction were done with Python 3.10, utilizing the SimpleITK40,41 package.
While the STD of the normative values across the 135 segmented regions can be estimated from each individual organ (Table S2), we limit our robustness analysis – that is, the Test/Retest variability – to 10 target organs that are known to be involved in a number of prevalent systemic diseases: liver, spleen, lungs (all five lobes), brain, pancreas, kidneys (left and right), heart, subcutaneous fat, visceral fat, and skeletal muscle. Volumes of the latter three tissues were defined at the vertebral L3 level. Here, the L3 level was selected as a well-established surrogate location for global body-composition measurements42,43,44 and more efficient delineation and verification of the fat and muscle segments for subsequent model training.
To evaluate potential sex-based differences in imaging-derived readouts, we performed a group-level comparison using the unpaired Student’s t-test, as a statistical assessment of between-group variability. Further, we assessed the repeatability of the Test and Retest scans at both the group and the subject levels. For the group analysis, we calculated the region-based averages across all 48 subjects, from which we derived statistical differences between Test and Retest readouts using the relative %-difference and the coefficient of variation (CV). We then used a paired Student’s t-test to assess the statistical significance of within-subject repeatability since each subject contributes a directly linked Test-Retest pair. Lastly, the Intraclass Correlation Coefficient (ICC) was used to evaluate repeatability for each organ and parameter45,46, specifically ICC(3,1), which assesses absolute agreement in repeated measures from the same subjects under identical conditions46. For the subject-level analysis, we computed the relative %-difference between the Test and Retest scans for each region on a per-subject basis, averaging these differences across the 48 subjects.
In principle, normative data (Table S2), as included in this healthy cohort, can be used to assess aberrations of tissue metabolism, organ volume, or organ density, as available from cohort-specific readouts of PET (SUV) and CT ([mL], [HU]). Disease-related aberrations can be detected as long as their quantitative impact on CT or PET readouts is larger than the Test/Retest variability. Here, we computed z-scores to highlight subject-specific deviations from the established norm, such as SUV, HU, and volume for each of the 135 segmented organs. The following formula (I) was applied to each organ parameter set to compute the z-score, denoted as \(z\):
The resulting z-scores can be visualized on an organ and voxel level47,48,49. For illustration purposes, we generate an organ atlas that highlights z-scores as deviations from the norm with 2 STDs as a cut-off to filter out noise.
To further expand the usability of this dataset in terms of chronobiological assessments, we report the start time of the Test and Retest PET/CT acquisition for each subject in Table 1. The time of day column indicates whether scans were performed before noon, in the afternoon, or the evening.
Facial anonymization of the image data was performed prior to data sharing. Defacing was applied to the PET and CT images of each subject by first extracting a facial segmentation mask from the CT using the “face” task of TotalSegmentator version 2.10.050. This mask was then applied to both the CT and PET images; for PET, the mask was coregistered using nearest-neighbor interpolation. In both modalities, the masked facial region was downsampled and subsequently upsampled to obscure identifiable features. The pixelated region was reinserted into the corresponding original image using the segmentation mask, effectively replacing the original facial anatomy with an unrecognizable version. All image analysis and quantification presented in this study were performed on the original, non-defaced PET and CT images.
Data Records
All imaging data are stored in anonymized and defaced NIfTI format. The entire image dataset includes the CT images, the static PET images at 57–62 min post-injection, and the segmentations generated by MOOSE with a total size of approximately 20.2 GB. It can be accessed unrestricted through Zenodo under the Creative Commons Attribution 4.0 International (CC BY 4.0) license, following this link: https://zenodo.org/records/16364694 or by searching for the term “QUADRA_HC” on Zenodo51.
The demographics for this cohort are summarized in Table S1 of this manuscript. Organ-based readouts for the entire cohort are presented in Table S2, Table S3, and Table S4. The contents of these tables are also provided in the repository51 as Excel files along with the image data, for download as Demographics (All).xlsx, Normative Readouts (All).xlsx, Normative Readouts (Male).xlsx, and Normative Readouts (Female).xlsx, respectively (Fig. 3).
Folder structure of the QUADRA_HC dataset. Each subject folder, identified by the subject ascending ID, QUADRA_HC_001 to QUADRA_HC_048, contains a Test and Retest folder in which the PET image (scaled to SUV), the low-dose CT used for attenuation correction, and a folder containing the segmentations are placed. The segmentation files contain 135 distinct regions of interest as provided by MOOSE25. All image and segmentation files are provided in anonymized and defaced NIfTI format. The demographics and normative readouts of the cohort for all, all female, and all male subjects are provided at the top level of the QUADRA_HC folder.
Figure 3 shows the directory structure of the imaging and data of this study protocol. The imaging-data folder contains one folder per subject, split into “Test” and “Retest” acquisitions, each containing the corresponding CT and PET images along with anatomical segmentations in anonymized and defaced NIfTI format. The anatomical segmentations are grouped within eight different multi-label files corresponding to distinct segmentation classes (Fig. 4): “Body-Composition,” “Cardiac,” “Muscles,” “Organs,” “Peripheral Bones,” “Ribs,” “Digestive,” and “Vertebrae”.
Overview of all organ/tissue segmentations as extracted by MOOSE25. For the purpose of this report, we share mean, STD, median, minimum, and maximum readouts for CT and PET, as well as the organ/tissue volume for each subject at Test and Retest (see main text for details).
Technical Validation
Our technical validation was limited to 48 healthy controls without subsequent incidental findings. The inclusion of the remaining 48 healthy controls and completion of the study protocol for each participant (Fig. 1) took 312 days. All subjects underwent WB-FDG-PET/CT imaging twice, with a mean time difference of (38 ± 10) days. Examples of the CT and PET image quality of a female and male healthy subject undergoing Test and Retest FDG-PET/CT imaging are shown in Figs. 5, 6, respectively.
Normative organ readouts
A detailed list of all 135 regions that were segmented by our in-house segmentation tool, MOOSE25 is shown in Fig. 4. Table S2 lists the normative values extracted from the Test and Retest PET/CT examination that were averaged across the 48 included healthy controls. These values correspond to values reported in previous studies of SUV in healthy subjects52,53,54. However, the reported literature values stem mostly from a restricted number of volumes of interest only. Furthermore, some of their reported values were extracted from specific regions within target organs rather than from the entire organ. In contrast to these reports, our readouts – though confined to Caucasian controls - relate to a significantly larger number of target organs and tissues, and they provide whole-organ context and analyses.
While normative values were computed across all segmented organs and tissues, the assessment of potential sex differences focuses specifically on the aforementioned subset of organs selected for repeatability analysis: liver, spleen, lungs (including all five lobes), brain, pancreas, kidneys (left and right), heart, subcutaneous fat, visceral fat, and skeletal muscle. The unpaired t-test analysis revealed statistically significant differences between male and female subjects across all readout parameters in several organs, as denoted by the asterisk in Fig. 7. The mean SUV was significantly different between male and female cohorts in the skeletal muscle (p < 0.01), myocardium (p < 0.01), right lower lung lobe (p = 0.02), and left lower lung lobe (p = 0.02), whereas good agreement was observed in all other regions. Differences were more pronounced for Hounsfield units and volumes, where most regions showed significant disparities between the male and female cohorts. Table S3 and Table S4 report the normative readout values for the male and female gender matched subcohorts, respectively, in addition to the complete coverage of all 48 subjects in Table S2.
Slope plots showing Test (left side of each slope) and Retest (right side) measurements for PET activity [SUV], CT density [HU], and CT volume [mL] across 10 reference regions in 48 healthy subjects (R = right, L = left). Male subjects are shown in light blue, females in light pink. Above each plot, the mean intra-subject percentage difference (Δ̄%) is indicated; below, the group-level mean absolute percentage difference (Δ%). The asterisks indicate statistically significant differences between males and females. Overall, organ-specific mean values remained stable between Test and Retest, with only minor variability, supporting the robustness of these metrics in healthy individuals.
Repeatability assessment
In order to employ normative values as a reference to compare potential disease-induced metabolic or tissue density aberrations, robustness values must be established. In other words, any aberration caused by or correlated with a systemic disease must cause deviations from a pre-established norm that are significantly different from the STD of the normative data. Therefore, we have performed test and retest scans as Test and Retest. Figure 7 visualizes the organ readouts at Test and Retest with slope plots of selected target organs from the healthy cohort (N = 48). The plots demonstrate a strong agreement between timepoints for individual subjects and their CT-based density and volume as well as PET-based SUV readouts, showing mostly shallow and tightly packed slopes indicating only minor changes between Test and Retest, not only at the subject level, but also at the group level. Exceptions were observed in the renal and myocardial SUV. These visually assessed results underscore the robustness of the measured parameters and support their application as stable normative baselines in clinical and research contexts, which was confirmed by our statistical analysis outlined below.
Overall, the SUV exhibited a strong consistency, both at the group and the subject levels (Table 2), thereby reaffirming the robustness of PET-based quantitative assessments. In terms of group-level findings, the SUV of the key organs varied by less than 5%, except for the kidneys (5.3% < = Δ% < = 6.5%) and the heart (Δ% = 6.1%), both of which exert an intrinsically high variability of FDG uptake. The calculated ICC(3,1) values supported these observations, with most organs showing excellent agreement (ICC > 0.95), except for skeletal muscle (ICC = 0.71), heart (ICC = 0.01), kidneys (ICC = 0.49 left, 0.39 right) and pancreas (ICC = 0.43), indicating moderate and poor repeatability, potentially due to the motion-induced spatial intra-scan mismatch between PET and CT. Furthermore, the SUV of skeletal muscle was significantly different between scans (p < 0.05), likely due to a difference in muscle activity shortly before the scans. Subject-level analysis corroborated these observations, indicating that the majority of organ-based SUV readouts remained stable across repeated scans (Δ% < 9%). We did observe a noticeable change in Δ% of 11% (subject level) in the SUV readout of visceral fat, which was likely due to changes in the weight of the subjects between the Test and Retest scans. The calculated CV from the Test (11.4%) and Retest (10.9%) for PET images in the liver (not reported in the tables) was well below the reported threshold of 15%, as recommended in the EARL guidelines55,56.
For tissue density – measured in HU, the group-level comparisons (Table 3) showed consistency across all target regions with small deviations of Δ% <2%. Of note, the %-differences were highest for the lower lung lobes at ~3%. The paired t-tests revealed significant differences in the lungs, heart, and subcutaneous fat regions. ICC(3,1) values indicated excellent repeatability in most tissues (ICC > 0.95), with slightly lower values for the heart (ICC = 0.85) and brain (ICC = 0.79), suggesting moderate consistency in these regions. These differences were likely driven by breathing (lung area) and motion (heart) artefacts in either examination, and presumably by weight changes and alterations in body composition between the two PET/CT scans. However, the correlation between tissue density and weight changes needs to be further investigated. On the subject level, the lung lobes expressed the highest percentage differences in tissue density of 4.4%–7.9%, with the remaining organs staying well below 1%. This observation confirmed the motion-induced deviations again, as the lower lung lobes showed differences on the higher end of the determined range.
Both CT (HU) and PET (SUV) exhibit generally low group‐level variability (<6% for most organs), indicating good overall repeatability, supported by ICC measures. At the single‐subject level, they remain stable in most tissues. Still, each modality has its expected outliers: PET shows a significant day‐to‐day fluctuation in the heart (Δ% ≈ 64%) and generally lower ICC values, most likely due to the metabolic variability of subjects. In comparison, tissue density exhibits relatively high variability in the lungs (Δ% up to 7.9%). Apart from these regions, both imaging modalities exhibit good repeatability.
Organ volume measurements proved to be the most repeatable, with group-level analyses (Table 4) indicating less than 3.5% variation between Test and Retest scans for almost all target organs. Small but significant differences appeared in the brain (p = 0.04) and kidney (p = 0.04) in the analyses. Repeatability was further confirmed by high ICC(3,1) values across all organs (ICC > 0.95, except in the liver and lung lobes), including the brain and kidneys, which showed significant group-level differences but retained strong agreement in volumetric measurements. In the subject-level assessment, the percentage differences in body-composition volumes and the lungs were more pronounced, as weight changes and breathing artefacts had a greater impact at the subject level.
Despite these described slight variations, the study exhibits excellent overall repeatability, confirming that Test and Retest scans provide reliable and consistent quantitative measurements across all three parameters. Exceptions, such as myocardial and renal SUV fluctuations, were to be expected, such as slight but noticeable changes in volume due to potential weight changes of subjects.
Application of normative readouts and findings
The example of a patient-specific z-score atlas is shown in Fig. 8. These data articulate the value of a more systemic analysis of WB-PET/CT readouts in the presence of malignant disease. While it relays corollaries to the presence of a systemic disease, the potential application of such patient maps should be reviewed in more detail as the availability of normative databases expands.
Example of organ-based aberrations of the norm: 55-y/o male (QUADRA_HC_049; excluded from the shared dataset) was found with thyroid cancer. The organ-based readouts of the subject were compared to the respective normative values derived from the cohort of 48 healthy controls (Table S2). From left to right: coronal CT, coronal PET, organ-based aberrations (z-score) for SUV, density (HU), and volume. As expected, the SUV of the thyroid changed by more than 2 STD. In addition, an increased liver volume and lower liver tissue density were observed when comparing the patient to the average of the corresponding cohort. Of note, this figure reports organ-based deviations of the norm (>2STD) for illustration purposes only; potentially disease-induced changes cannot be confirmed with the data at hand.
Finally, of all subjects enrolled, two subjects presented with incidental findings on their 1st (Test) WB-FDG-PET/CT scan: a T2N0M0 papillary thyroid carcinoma and an adenocarcinoma of the lung stage T1cN0M0. Both subjects were successfully treated for their cancers, and their data were removed from the shared data set. These incidental findings also underscore the potential of systematic screening in uncovering clinically relevant conditions that might otherwise remain undiagnosed. Interestingly, the 4% incidence in here is in the range of incidences reported by earlier screening studies of asymptomatic subjects undergoing static WB-FDG-PET/CT imaging in Japan57,58.
Usage Notes
All imaging data are presented in NIfTI format, ensuring the privacy of the study participants while allowing for easy use in further analysis. This format can be opened with most visualization software, including 3D Slicer (https://www.slicer.org/) and ITK-SNAP (http://www.itksnap.org/pmwiki/pmwiki.php). DICOM to NIfTI conversion was performed using the software dcm2niix59, and all image processing was conducted using Python and the SimpleITK40,41 package.
More advanced stratification and analysis beyond sex-matched subcohorts can be achieved by referencing the subject information in the demographics in Table S1.
Limitations
This dataset is made of whole-body [18F]FDG-PET/CT imaging data acquired with a Siemens Quadra PET/CT system of 48 healthy controls. It includes paired test-retest scans and organ-level segmentations. The cohort contains equal male and female subjects across a reasonably limited range of ages and BMIs; however, the sample size is still low (n = 48), thus, limiting the generalizability of any subgroup analyses (e.g., stratification by age, BMI, sex). Further, all organ segmentations were generated automatically using the MOOSE algorithm25. Due to its previously reported high accuracy, we did not perform additional visual verification of each of the 135 segmentations per subject. Given the extended imaging protocol, involuntary intra-scan motion of subjects may cause local misalignments of PET and CT information that may translate into a bias of the attenuation-corrected PET data (despite the lack of visible artifacts) as well as slight misalignments of the CT-based segmentation mask and corresponding tracer uptake on PET. One specific area of recurring mismatch we observed was the hands, likely attributed to the involuntary movement during the long acquisition time. However, these misalignments appeared to have only localized effects and did not substantially affect image quality. Bespoke misalignment of segmentation masks is potentially more relevant when analysing PET data derived from the last 5 minutes of the emission scan, which are acquired 57 minutes after the initial CT scan. Here, motion-induced misalignments are more critical in central regions such as the torso, mainly observed in the lungs due to breathing. In contrast, mismatches in the extremities are less likely to impact quantitative analyses.
Finally, the release of raw listmode PET data was not feasible for this study. Each scan generated ~180 GB of listmode data, amounting to >15 TB across the entire cohort, which exceeds the capacity of commonly used public repositories (e.g., Zenodo limits are 200 GB). Moreover, residual metadata embedded in listmode headers (e.g., acquisition times, system identifiers, protocol strings) require vendor-specific anonymisation and institutional review to ensure compliance with data governance regulations.
Within these limitations, these data support the development of a normative reference for CT-based body composition and systemic FDG uptake in healthy controls and thus offer valuable insights into the repeatability in multi-organ whole-body FDG-PET/CT analysis. By making this dataset openly available, we aim to facilitate future research into systemic imaging biomarkers and support methodological developments in quantitative PET/CT analysis of health and disease.
Data availability
The dataset is available on Zenodo at https://zenodo.org/records/16364694 or https://doi.org/10.5281/zenodo.16364694, and can also be found by searching for “QUADRA_HC”51.
Code availability
The MOOSE code is open-source and available online through GitHub at https://github.com/ENHANCE-PET/MOOSE, along with extensive documentation. The image dataset is available for download at Zenodo via unrestricted access under the Creative Commons Attribution 4.0 International (CC BY 4.0) license, following this link: https://zenodo.org/records/16364694 or by searching for the term “QUADRA_HC” on Zenodo51. No separate repository is provided for storing the code used for analysis. All analysis was performed with Python using the SimpleITK package and the available functions to extract organ readouts and perform computational operations. 3D Slicer and ITK-SNAP can be downloaded free of charge following the previously mentioned links.
References
Sung, H. et al. Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries. CA Cancer J Clin 71, 209–249 (2021).
Savarese, G. et al. Global burden of heart failure: a comprehensive and updated review of epidemiology. Cardiovasc Res 118, 3272–3287 (2023).
Scheltens, P. et al. Alzheimer’s disease. Lancet 397, 1577–1590 (2021).
Beyer, T. et al. A combined PET/CT scanner for clinical oncology. J Nucl Med 41, 1369–1379 (2000).
Subramaniam, R. M. et al. Impact on Patient Management of [18F]-Fluorodeoxyglucose-Positron Emission Tomography (PET) Used for Cancer Diagnosis: Analysis of Data From the National Oncologic PET Registry. The Oncologist 21, 1079–1084 (2016).
Dahlbom, M. et al. Whole-body positron emission tomography: Part I. Methods and performance characteristics. J Nucl Med 33, 1191–1199 (1992).
Czernin, J., Allen-Auerbach, M. & Schelbert, H. R. Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006. J Nucl Med 48(Suppl 1), 78S–88S (2007).
Hofman, M. S. & Hicks, R. J. Moving Beyond ‘Lumpology’: PET/CT Imaging of Pheochromocytoma and Paraganglioma. Clin Cancer Res 21, 3815–3817 (2015).
Hacker, M., Hicks, R. J. & Beyer, T. Applied Systems Biology-embracing molecular imaging for systemic medicine. Eur J Nucl Med Mol Imaging 47, 2721–2725 (2020).
Shiyam Sundar, L. K., Hacker, M. & Beyer, T. Whole-Body PET Imaging: A Catalyst for Whole-Person Research? J Nucl Med 64, 197–199 (2023).
Slart, R. H. J. A. et al. Total-Body PET/CT Applications in Cardiovascular Diseases: A Perspective Document of the SNMMI Cardiovascular Council. J Nucl Med 65, 607–616 (2024).
Minoshima, S., Cross, D., Thientunyakit, T., Foster, N. L. & Drzezga, A. 18 F-FDG PET Imaging in Neurodegenerative Dementing Disorders: Insights into Subtype Classification, Emerging Disease Categories, and Mixed Dementia with Copathologies. J Nucl Med 63, 2S–12S (2022).
Sun, T. et al. Identifying the individual metabolic abnormities from a systemic perspective using whole-body PET imaging. Eur J Nucl Med Mol Imaging 49, 2994–3004 (2022).
Beyer, T., Freudenberg, L. S., Townsend, D. W. & Czernin, J. The future of hybrid imaging-part 1: hybrid imaging technologies and SPECT/CT. Insights Imaging 2, 161–169 (2011).
Ferrara, D. et al. Detection of cancer‐associated cachexia in lung cancer patients using whole‐body [18 F]FDG‐PET/CT imaging: A multi‐centre study. J cachexia sarcopenia muscle 15, 2375–2386 (2024).
Gatidis, S. & Kuestner, T. A whole-body FDG-PET/CT dataset with manually annotated tumor lesions (FDG-PET-CT-Lesions). The Cancer Imaging Archive https://doi.org/10.7937/GKR0-XV29 (2022).
Oreiller, V. et al. Head and neck tumor segmentation in PET/CT: The HECKTOR challenge. Medical Image Analysis 77, 102336 (2022).
Deep-learning Evaluation for Enhanced Prognostics - PSMA PET - Grand Challenge. grand-challenge.org https://deep-psma.grand-challenge.org/dataset/.
Gatidis, S. et al. Results from the autoPET challenge on fully automated lesion segmentation in oncologic PET/CT imaging. Nat Mach Intell 6, 1396–1405 (2024).
Selfridge, A. R. et al. Low-Dose CT Images of Healthy Cohort (Healthy-Total-Body-CTs). The Cancer Imaging Archive https://doi.org/10.7937/NC7Z-4F76 (2023).
Shiyam Sundar, L. et al. The ENHANCE-PET Framework: An initiative to engage the imaging community in Advancements in Total-Body PET Analysis. EANM’23 Abstract Book Congress Sep 9-13, 2023. Eur J Nucl Med Mol Imaging 50, 1–898 (2023).
Kinahan, P. E., Townsend, D. W., Beyer, T. & Sashin, D. Attenuation correction for a combined 3D PET/CT scanner. Med Phys 25, 2046–2053 (1998).
Burger, C. et al. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med Mol Imaging 29, 922–927 (2002).
Watson, C. C., Newport, D. & Casey, M. E. A Single Scatter Simulation Technique for Scatter Correction in 3D PET. in Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine (eds Grangeat, P. & Amans, J.-L.) 255–268. https://doi.org/10.1007/978-94-015-8749-5_18 (Springer Netherlands, Dordrecht, 1996).
Shiyam Sundar, L. K. et al. Fully Automated, Semantic Segmentation of Whole-Body 18F-FDG PET/CT Images Based on Data-Centric Artificial Intelligence. J Nucl Med 63, 1941–1948 (2022).
Boellaard, R. et al. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0. Eur J Nucl Med Mol Imaging 42, 328–354 (2015).
Chia, C. W., Egan, J. M. & Ferrucci, L. Age-Related Changes in Glucose Metabolism, Hyperglycemia, and Cardiovascular Risk. Circ Res 123, 886–904 (2018).
O’Malley, K., Crooks, J., Duke, E. & Stevenson, I. H. Effect of age and sex on human drug metabolism. Br Med J 3, 607–609 (1971).
Power, C. & Thomas, C. Changes in BMI, duration of overweight and obesity, and glucose metabolism: 45 years of follow-up of a birth cohort. Diabetes Care 34, 1986–1991 (2011).
Peiris, A. N., Struve, M. F., Mueller, R. A., Lee, M. B. & Kissebah, A. H. Glucose metabolism in obesity: influence of body fat distribution. J Clin Endocrinol Metab 67, 760–767 (1988).
Yoshizawa, H., Gazes, Y., Stern, Y., Miyata, Y. & Uchiyama, S. Characterizing the normative profile of 18F-FDG PET brain imaging: sex difference, aging effect, and cognitive reserve. Psychiatry Res 221, 78–85 (2014).
Wulan, S. N., Westerterp, K. R. & Plasqui, G. Ethnic differences in body composition and the associated metabolic profile: A comparative study between Asians and Caucasians. Maturitas 65, 315–319 (2010).
Gradinscak, D. J., Fulham, M. J., Mohamed, A. & Constable, C. J. Skeletal Muscle Uptake Detected on FDG PET 48 Hours After Exertion. Clinical Nuclear Medicine 28, 840–841 (2003).
Parida, G. K., Roy, S. G. & Kumar, R. FDG-PET/CT in Skeletal Muscle: Pitfalls and Pathologies. Seminars in Nuclear Medicine 47, 362–372 (2017).
van Sluis, J. et al. Performance Characteristics of the Digital Biograph Vision PET/CT System. J Nucl Med 60, 1031–1036 (2019).
Schmidt, F. P. et al. Impact of the maximum ring difference on image quality and noise characteristics of a total-body PET/CT scanner. Z Med Phys S0939-3889(23), 00113–7, https://doi.org/10.1016/j.zemedi.2023.09.001 (2023).
Rausch, I., Mannheim, J. G., Kupferschläger, J., la Fougère, C. & Schmidt, F. P. Image quality assessment along the one metre axial field-of-view of the total-body Biograph Vision Quadra PET/CT system for 18F-FDG. EJNMMI Phys 9, 87 (2022).
Prenosil, G. A. et al. Performance Characteristics of the Biograph Vision Quadra PET/CT System with a Long Axial Field of View Using the NEMA NU 2-2018 Standard. J Nucl Med 63, 476–484 (2022).
Ferrara, D. et al. Sharing a whole-/total-body [18F]FDG-PET/CT dataset with CT-derived segmentations: an ENHANCE.PET initiative. Preprint at https://doi.org/10.21203/rs.3.rs-7169062/v1 (2025).
Beare, R., Lowekamp, B. & Yaniv, Z. Image Segmentation, Registration and Characterization in R with SimpleITK. J. Stat. Soft. 86 (2018).
Lowekamp, B., Chen, D., Ibanez, L. & Blezek, D. The Design of SimpleITK. Frontiers in Neuroinformatics 7 (2013).
Van den Broeck, J. et al. The correlation of muscle quantity and quality between all vertebra levels and level L3, measured with CT: An exploratory study. Front Nutr 10, 1148809 (2023).
Mourtzakis, M. et al. A practical and precise approach to quantification of body composition in cancer patients using computed tomography images acquired during routine care. Appl Physiol Nutr Metab 33, 997–1006 (2008).
Shen, W. et al. Total body skeletal muscle and adipose tissue volumes: estimation from a single abdominal cross-sectional image. J Appl Physiol (1985) 97, 2333–2338 (2004).
Wolak, M. E., Fairbairn, D. J. & Paulsen, Y. R. Guidelines for estimating repeatability. Methods Ecol Evol 3, 129–137 (2012).
Koo, T. K. & Li, M. Y. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J Chiropr Med 15, 155–163 (2016).
Friston, K. J. et al. Statistical parametric maps in functional imaging: A general linear approach. Human Brain Mapping 2, 189–210 (1994).
Gutschmayer, S. et al. The utilization of a normative [18 F] FDG-PET/CT database to highlight metabolic aberrations in cachectic lung cancer patients. in European Journal of Nuclear Medicine and Molecular Imaging vol. 51 S505–S505 (SPRINGER ONE NEW YORK PLAZA, SUITE 4600, NEW YORK, NY, UNITED STATES, 2024).
Gutschmayer, S. et al. Metabolic aberrations in lung cancer patients as detected with a normative whole-body [18 F] FDG-PET/CT database. in European Journal of Nuclear Medicine and Molecular Imaging vol. 51 S504–S505 (SPRINGER ONE NEW YORK PLAZA, SUITE 4600, NEW YORK, NY, UNITED STATES, 2024).
Wasserthal, J. et al. TotalSegmentator: Robust Segmentation of 104 Anatomic Structures in CT Images. Radiology: Artificial Intelligence 5, e230024 (2023).
Medical University of Vienna. Total-Body [18F]FDG-PET/CT Imaging of Healthy Controls: Test/Retest Data for Systemic, Multi-Organ Analysis. Medical University of Vienna https://doi.org/10.5281/ZENODO.16364694 (2025).
Oliveira, A. L., Azevedo, D. C., Bredella, M. A., Stanley, T. L. & Torriani, M. Visceral and subcutaneous adipose tissue FDG uptake by PET/CT in metabolically healthy obese subjects: Adipose Tissue FDG Uptake in MHO Subjects. Obesity 23, 286–289 (2015).
Dias, A. H., Hansen, A. K., Munk, O. L. & Gormsen, L. C. Normal values for 18F-FDG uptake in organs and tissues measured by dynamic whole body multiparametric FDG PET in 126 patients. EJNMMI Res 12, 15 (2022).
Zincirkeser, S., Sahin, E., Halac, M. & Sager, S. Standardized uptake values of normal organs on 18F-fluorodeoxyglucose positron emission tomography and computed tomography imaging. J Int Med Res 35, 231–236 (2007).
R. Boellaard, A.T. Willemsen, B. Arends, & E.P. Visser. EARL procedure for assessing PET/CT system specific patient FDG activity preparations for quantitative FDG PET/CT studies. (2018).
Gnesin, S. et al. Phantom-based image quality assessment of clinical 18F-FDG protocols in digital PET/CT and comparison to conventional PMT-based PET/CT. EJNMMI Phys 7, 1 (2020).
Minamimoto, R. et al. Performance profile of FDG-PET and PET/CT for cancer screening on the basis of a Japanese Nationwide Survey. Ann Nucl Med 21, 481–498 (2007).
Ghotbi, N., Iwanaga, M., Ohtsuru, A., Ogawa, Y. & Yamashita, S. Cancer screening with whole-body PET/CT for healthy asymptomatic people in Japan: re-evaluation of its test validity and radiation exposure. Asian Pac J Cancer Prev 8, 93–97 (2007).
Li, X., Morgan, P. S., Ashburner, J., Smith, J. & Rorden, C. The first step for neuroimaging data analysis: DICOM to NIfTI conversion. J Neurosci Methods 264, 47–56 (2016).
Acknowledgements
Sebastian Gutschmayer was supported in parts by a research agreement between Siemens Healthineers and the Medical University Vienna. Daria Ferrara and Josef Yu were supported by the Austrian Science Fund (FWF) (10.55776/I5902) under the ERA-NET Cofund scheme of the Horizon 2020 Research and Innovation Framework Programme of the European Commission Research Directorate-General, Grant Agreement No. 779282. Öykü Özer and Manuel Pires were supported by the FWF (ANR-FWF) [FWF-ANR I6174 (IOP-PET)]. The support of the ICPO Academy for the complementary study of wearable-driven biosignals is greatly appreciated. We thank the technologists and administrative support of the Department of Nuclear Medicine at the Medical University of Vienna for their operational support of this study. We thank Gary Cook, MD, PhD, and Erin Stella Sullivan, PhD, RD, from King’s College London, UK, for helpful advice and discussions of the manuscript.
Author information
Authors and Affiliations
Contributions
T.B., M.H., B.K.G., I.R., G.K., W.L., and S.G.: Conceptualization of the project and study. S.G., J.Y., Ö.Ö., D.F., M.P., and B.R.: Data collection and documentation. S.G., D.F., L.K.S.S., D.M.: Data processing and analysis. S.G., D.F., L.K.S.S.: Data pseudonymization. S.G., J.Y., B.K.G., D.F., M.P., I.R., Z.C., L.K.S.S., D.M. and T.B.: Data interpretation. The manuscript was reviewed and approved by all co-authors.
Corresponding author
Ethics declarations
Competing interests
T.B. and L.K.S.S. are co-founders of Zenta GmbH without dualities of interest with this manuscript. TB has received research support through Siemens Healthineers, which is not competing with this manuscript.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Gutschmayer, S., Yu, J., Geist, B.K. et al. Whole-Body [18F]FDG-PET/CT Imaging of Healthy Controls: Test/Retest Data for Systemic, Multi-Organ Analysis. Sci Data 12, 1707 (2025). https://doi.org/10.1038/s41597-025-05997-4
Received:
Accepted:
Published:
Version of record:
DOI: https://doi.org/10.1038/s41597-025-05997-4
This article is cited by
-
Total-body [18F]FDG-PET/CT imaging of healthy volunteers with minimal effective dose
European Journal of Nuclear Medicine and Molecular Imaging (2025)