Table 3 Comparison of the properties of supercritical CO2 at different pressures with water at atmospheric pressure for different operating temperatures33.
From: Heat transfer enhancement using CO2 in a natural circulation loop
Pressure of CO2 (bar) | Avg. Temperature, Tavg(°C) | Density ratio, ρCO2/ρWater | Specific heat ratio, Cp_CO2/ Cp_Water | Thermal conductivity ratio, kCO2/kWater | Viscosity ratio, μCO2/μWater | Ratio of volumetric coefficient, βCO2/βWater |
|---|---|---|---|---|---|---|
75 | 41 | 0.23 | 0.75 | 0.05 | 0.03 | 56.68 |
46 | 0.21 | 0.59 | 0.05 | 0.03 | 37.89 | |
51 | 0.19 | 0.50 | 0.05 | 0.04 | 28.21 | |
80 | 41 | 0.27 | 1.05 | 0.06 | 0.03 | 83.50 |
46 | 0.24 | 0.72 | 0.05 | 0.04 | 48.29 | |
51 | 0.22 | 0.58 | 0.05 | 0.04 | 33.70 | |
90 | 41 | 0.44 | 2.89 | 0.11 | 0.05 | 240.54 |
46 | 0.33 | 1.27 | 0.07 | 0.04 | 91.65 | |
51 | 0.28 | 0.83 | 0.06 | 0.04 | 51.69 |