Table 2 Flow parameters obtained in vivo for all study participants.
From: A comparative study on the analysis of hemodynamics in the athlete’s heart
Parameters | Unit | Healthy#1 | Healthy#2 | Athlete#1 | Athlete#2 | ARVC#1 | ARVC#2 |
---|---|---|---|---|---|---|---|
Body surface | m2 | 1.77 | 2.01 | 2.16 | 1.94 | 1.88 | 1.68 |
RV ejection fraction | % | 53 | 47 | 49 | 52 | 42 | 42 |
RV EDV | ml | 170 | 204 | 278 | 196 | 216 | 211 |
EDDi of RVOT | mm | 17 | 16 | 18.5 | 16.5 | 17 | 15 |
Thickness of RVOT | mm | 5 | 5 | 6 | 6 | 4.5 | 4 |
Heart beat | bpm | 66 | 62 | 53 | 54 | 63 | 65 |
Stroke volume | ml | 90.6 | 88.2 | 136 | 101 | 87.5 | 91.6 |
Cardiac output | Lt/min | 5.98 | 5.31 | 7.21 | 5.45 | 5.51 | 5.95 |