Table 12 Ablation results of MFRANet under Gaussian noise (%).
Methods | 6 dB | 4 dB | 2 dB | 0 dB | − 2 dB | − 4 dB | − 6 dB | |
---|---|---|---|---|---|---|---|---|
MFRANet | 93.91 | 88.89 | 80.37 | 67.12 | 50.53 | 36.68 | 28.16 | |
MDSCMod | No DSC | 88.58 | 82.80 | 72.30 | 59.21 | 44.44 | 33.18 | 25.27 |
No DSC | 91.78 | 86.61 | 77.63 | 62.71 | 50.38 | 37.29 | 26.18 | |
No ECA | 91.93 | 87.82 | 81.13 | 67.58 | 49.92 | 36.83 | 27.25 | |
ERCAMod | No D&E | 92.39 | 88.28 | 78.84 | 66.36 | 49.32 | 37.29 | 27.55 |