Table 2 MTF-Based Energy Access Matrix.

From: Optimal planning and sizing of microgrid cluster for performance enhancement

Attributes

 

Tier 1

Tier 2

Tier 3

Tier 4

Tier 5

Power

Capacity

Peak power

\(\:\ge\:\) 3 W

\(\:\ge\:\) 50 W

\(\:\ge\:\) 200 W

\(\:\ge\:\) 800 W

\(\:\ge\:\) 2 KW

Daily

\(\:\ge\:\)12 Wh

\(\:\ge\:\)200 Wh

\(\:\ge\:\) 1 KWh

\(\:\ge\:\) 3.4 KWh

\(\:\ge\:\) 8.2 KWh

Availability

Daily hours

\(\:\ge\:\)4 hrs.

\(\:\ge\:\) 4 h.

\(\:\ge\:\) 8 h.

\(\:\ge\:\) 16 h.

\(\:\ge\:\) 23 h.

Hrs. per night

\(\:\ge\:\) 1 h.

\(\:\ge\:\) 2 h.

\(\:\ge\:\)3 hrs.

\(\:\ge\:\) 4 h.

\(\:\ge\:\)4 hrs.

Supported

Appliances

Per

Household

Very low-power

appliances

(3–49 W)

Low-power

appliances

(< 200 W)

Medium-power

appliances

(< 800 W)

High-power

appliances

(< 2000 W)

Very high-power

appliances

(2KW or more)

P

(qty.)

Daily energy

P

(qty.)

Daily energy

P

(qty.)

Daily energy

P

(qty.)

Daily energy

P

(qty.)

Daily energy

Lighting

6 W

(3)

36Wh

10 W

(5)

80Wh

10 W

(5)

80Wh

10 W

(5)

80Wh

10 W

(5)

80Wh

Phone

charging

6 W

(2)

24Wh

9 W

(3)

72Wh

9 W

(3)

72Wh

9 W

(3)

72Wh

9 W

(3)

72Wh

Radio

3 W

(1)

12Wh

6 W

(2)

48Wh

6 W

(2)

48Wh

6 W

(2)

48Wh

6 W

(2)

48Wh

TV

  

12 W

(1)

96Wh

12 W

(1)

96Wh

12 W

(1)

96Wh

12 W (1)

96Wh

Fan

  

15 W

(1)

90Wh

30 W

(2)

240Wh

30 W

(2)

240Wh

30 W (2)

240Wh

Fridge

    

75 W

(1)

600Wh

100 W (1)

800Wh

200 W

(1)

1600Wh

Rice cooker

    

250 W (1)

250Wh

350 W (1)

350Wh

400 W (1)

400Wh

Iron

      

1.1KW (1)

330Wh

1.1KW (1)

330Wh

Washing machine

      

0.5KW

(1)

500Wh

0.5KW (1)

500Wh

Air conditioner

        

1.5 kW (1)

4.5 KWh

Reliability

\(\:\ge\:\) 14 disruptions per week

< 14 disruptions per week

< 14 disruptions per week, total duration < 2 h

< 3 disruptions per week, total duration < 2 h

Affordability

Low income

Medium income

High income