Table 3 The test results were adjusted based on the deviation of the initial mixing test data.

From: Research and design of multiple gas mixing system in modified atmosphere packaging

Volume concentration setting

(%V/V)

Gas partial pressure setting

(K Pa)

Measured volume concentration

(%V/V)

Relative deviation

(%)

Number

CO2

O2

N2

CO2

O2

N2

CO2

O2

CO2

O2

1

2

8

90

10.35

41.20

450

1.97

7.91

1.5

1.1

2

5

10

85

20.12

40.28

340

4.93

9.87

1.4

1.3

3

10

10

80

50.19

50.26

400

10.12

9.89

1.2

1.1

4

10

15

75

80.26

120.42

600

10.1

15.14

1.0

0.9

5

15

15

70

119.96

120.09

560

15.13

15.12

0.9

0.8

6

15

20

65

150.17

200.23

650

14.9

19.88

0.7

0.6

7

20

20

60

200.15

200.26

600

19.89

20.07

0.6

0.4

8

20

25

55

199.98

250.05

550

20.12

24.93

0.6

0.3

9

25

25

50

259.98

259.89

520

24.90

25.08

0.4

0.3

10

30

30

40

300.12

300.23

400

29.89

29.90

0.3

0.4

Average value

0.86

0.72