Table 1 EIS parameters associated with impedance curves for of C-steel in 2.0 M H2SO4 solution with and without Irish ivy extract (IIE) at 298 K under dynamic conditions.

From: An eco-friendly corrosion inhibitor for steel used in desalination systems during acid cleaning: Irish ivy extract

IIE extract

(g L-1)

Rs

Ω cm2

M ± SD

Rct

Ω cm2

M ± SD

Cdl

μF cm-2

M ± SD

χ2

n

ηR%

Blank

0.1

0.2

0.3

0.4

0.5

0.48 ± 0.02

0.51 ± 0.02

0.54 ± 0.02

0.58 ± 0.01

0.62 ± 0.02

0.72 ± 0.02

13.34 ± 1.12

58.07 ± 1.24

67.34 ± 1.78

88.49 ± 2.53

171.43 ± 2.54

232.25 ± 3.04

274 ± 2.3

236 ± 2.1

179 ± 2.2

93 ± 1.8

69 ± 1.3

87 ± 1.3

1.7 × 10−3

1.6 × 10−3

1.0 × 10−3

1.2 × 10−3

1.9 × 10−3

1.7 × 10−3

0.82

0.91

0.92

0.93

0.93

0.93

-

77.0

80.2

85.0

92.2

94.2