Table 11 Performance of the proposed model.
Proposed model | Accuracy | MAE | RMSE |
---|---|---|---|
Two-stage PD Diagnosis and severity classification model using (RFT + ER) | 97.5% ± 2.1% (PD detection) and 96.4% ± 2.3% for severity assessment | 0.065 ± 0.024 | 0.080 ± 0.06 |
Proposed model | Accuracy | MAE | RMSE |
---|---|---|---|
Two-stage PD Diagnosis and severity classification model using (RFT + ER) | 97.5% ± 2.1% (PD detection) and 96.4% ± 2.3% for severity assessment | 0.065 ± 0.024 | 0.080 ± 0.06 |