Table 3 Equipment specifications.
Equipment | Specification | Accuracy | Range |
---|---|---|---|
Emission gas analyzer | CO2 | ± 4% | 0–20% |
CO | ± 1% | 0–20% | |
O2 | ± 3% | 0–25% | |
HC | ± 5% | 0–9999 ppm | |
NO | ± 5% | 0–5000 ppm | |
Opacity meter | Smoke opacity | ± 0.01% | 0-100% |
K-type thermocouple | Exhaust gas Temperature | ± 1% | 0 to 800 °C |
Shaft encoder | Speed | ± 0.2% | 0–720 ⁰CA |
Inclined manometer | Airflow rate | ± 2% | 0–2.99 m3/h |
Graduated cylinder | Diesel flow meter | ± 1% | 1 to 30 cm3 |
Load indicator | Load | ± 0.2% | 1 to 1000 W |