Table 1 Structural parameters of components.
From: Winding vibration caused by Lorentz force in shunt reactor and its control strategy
Component | Structural parameter/mm |
---|---|
Magnetic shield | Φin = 127, Φex = 974, height = 27.5 |
Core cake | Φin = 127, Φex = 464, height = 60/117.5 |
Core limb block | Φ = 60, height = 10/40/50 |
Wire disk | Φin = 724, Φex = 974, height = 10 |
Winding block | length = 125, width = 35, height = 6/30.5 |