Table 1 Structural parameters of components.

From: Winding vibration caused by Lorentz force in shunt reactor and its control strategy

Component

Structural parameter/mm

Magnetic shield

Φin = 127, Φex = 974, height = 27.5

Core cake

Φin = 127, Φex = 464, height = 60/117.5

Core limb block

Φ = 60, height = 10/40/50

Wire disk

Φin = 724, Φex = 974, height = 10

Winding block

length = 125, width = 35, height = 6/30.5