Table 4 Performance metrics, including accuracy (ACC), sensitivity (SEN), specificity (SPE), precision (PR), false positive rate (FPR), F1 scores and ROC curve (AUC), for all models in the context of the short axis view.
Model | ACC | SEN | SPE | PR | FPR | F1 score | AUC |
|---|---|---|---|---|---|---|---|
KNN | 0.92 | 0.66 | 0.90 | 1.00 | 0 | 0.80 | 0.69 |
SVM | 0.90 | 0.58 | 0.88 | 1.00 | 0 | 0.73 | 0.76 |
Bayesian | 0.80 | 0.58 | 0.86 | 0.58 | 0.13 | 0.58 | 0.58 |
RF | 0.82 | 0.50 | 0.85 | 0.66 | 0.07 | 0.57 | 0.59 |