Introduction

The World Health Organization (WHO) reported that cancer was the second leading cause of death for individuals under 70 age in 112 out of 183 countries in 2019. The global burden of cancer is expected to rise by 47% to 28.4 million cases in 20401. In pursuit of this goal to enhance treatment effectiveness, various approaches like chemotherapy, radiation therapy, and immunotherapy have been studied for treating cancer patients2. Despite advancements in cancer therapies leading to a decrease in the mortality rate3, these treatments have long-lasting side effects on the heart, directly impacting its structure and function, leading to heart disease and cardiotoxicity in cancer patients4,5. Anthracyclines (ATC) are crucial chemotherapy treatments for hematologic and solid cancers, particularly breast cancer. ATC can cause irreparable heart damage, and as dosage increases, so does the risk of cardiotoxicity6. Trastuzumab and Pertuzumab, humanized monoclonal antibodies targeting HER2 (aaHER2), are also widely used in breast cancer and have been shown to cause cardiotoxicity7,8. Anti-HER2 cardiac effects are not dose-dependent, and left ventricular systolic dysfunction (LVSD) is usually reversible with TZ treatment suspension or withdrawal. However, anti-HER2 medications can worsen and accelerate the harm caused by earlier ATC therapy9.

Chemotherapy-induced cardiotoxicity is defined as a 5–10% decrease in left ventricular ejection fraction (LVEF)10 alongside other complications, including cardiac arrhythmias, pericarditis and irreversible heart damage11.

Identifying cancer patients at high risk of cardiotoxicity is crucial for early detection and potential preventive measures, posing a significant challenge in clinical oncology12. Echocardiography, cardiac imaging, computed tomography of the heart, and cardiac magnetic resonance imaging are used to diagnose cardiac toxicity13,14. Echocardiography is the most widely used non-invasive method for screening cardiotoxicity15,16.The inexpensive cost and widespread availability of this method are utilized to evaluate systolic and diastolic function heart valve abnormalities17.

Two-dimensional echocardiography (2DE) is the preferred method for assessing cardiotoxicity in oncology patients, with LVEF being the most commonly used parameter18.

Many studies have examined the effect of chemotherapy and radiotherapy on reduced LVEF19 and reported that reduced LVEF before chemotherapy had a higher risk of subsequent cardiac events20. Despite the use of echocardiography in the diagnosis of cardiovascular diseases, some limitations such as the dependency on physician experience, low-quality and low-contrast images, and the estimation error of more than 14% can be noted21,22.

Previous research suggests that Machine learning (ML)based approaches can improve models for predicting cancer therapy-related cardiac dysfunction23,24 and automated echocardiography techniques using artificial intelligence (AI) can improve LVEF measurement accuracy and disease diagnosis25,26. However, its effectiveness can be hindered by interobserver variability and operator experience dependence. AI can address these challenges by enhancing consistency and reducing variance in image acquisition and interpretation. ML offers automated interpretations, reducing operator expertise, allowing echocardiography to accurately address cardiotoxicity and prompt early treatment initiation27,28,29. ML models have shown significant accuracy in predicting heart failure, atrial fibrillation, stroke, myocardial infarction, and cancer-related cardiac dysfunction (CTRCD)18,24,30. Studies explored radiomic features’ role in disease prognosis and treatment response, aiming to enhance medical decisions using new image processing methods and ML data analysis21,31,32,33,34,35,36,37 and there are limited radiomic studies to predict cardiotoxicity induced by chemotherapy.

Based on two study ML-based research should focus on the various complications that can occur after chemotherapy38,39. Two other studies have been performed on the clinical data of patients undergoing chemotherapy for colorectal cancer and breast cancer, respectively, showed that the development and comparison of different ML algorithms for predicting the risk of cardiotoxicity could predict better the decisions and prognosis of physicians24,40.

Therefore, considering the current challenges in ML-based prediction of cardiotoxicity in patients undergoing cancer treatment, this study aimed to analyze the radiomic features of baseline pre-chemotherapy echocardiographic images to predict late cardiotoxicity 12 months post-chemotherapy. Echocardiographic assessments performed 12 months after chemotherapy were used to determine cardiotoxicity based on LVEF decline. Additionally, we developed an ML model to enhance the accuracy of cardiotoxicity prediction.

Materials and methods

Study population

Inclusion criteria

This retrospective cross-sectional study was designed to include a more homogeneous patient population by focusing on breast cancer patients who were not candidates for surgery and were receiving systemic chemotherapy as their primary treatment modality. This selection ensures that the study population represents individuals for whom chemotherapy is the standard-of-care treatment, thereby concentrating on the subgroup most at risk for chemotherapy-induced cardiotoxicity.

In addition, all eligible patients underwent standard chemotherapy regimens that commonly included anthracycline-based agents or anti-HER2 therapies (e.g., Herceptin). These treatments are widely used in the management of breast cancer and are known for their potential cardiotoxic effects, making them a critical focus for our radiomics assessment. Eligible records required documentation of at least one complete cycle of either anthracycline or anti-HER2 therapy, along with comprehensive clinical and imaging data to facilitate a robust analysis of treatment-related cardiac changes.

Exclusion criteria

The records of all patients newly diagnosed with cancer at the Cardio-Oncology Department of Rajaei Cardiovascular Medical and Research Center were evaluated. Patients with a previous history of chemotherapy-related cardiovascular disease, open-heart surgery, or taking medications that significantly impair heart function, as well as those with abnormal echocardiograms before initiating treatment, were excluded from the study.

Additionally, Patients who did not have complete echocardiography follow-up or whose echocardiographic images were of suboptimal quality were excluded from the study.

Furthermore, patients whose echocardiographic images quality were deemed suboptimal were also excluded. It is noteworthy that all these patients underwent echocardiography both before and 12 months after chemotherapy. The total number of patients in this investigation was 150. According to the inclusion and exclusion criteria mentioned in the Methods and Standards section, 100 patients were finally selected and evaluated for further analysis and processing.

Ejection fraction decline determination

Pre-chemotherapy, images were used to predict cardiotoxicity via radiomics features among the patients, while 12 months post-chemotherapy images were used to estimate the EF difference between two episodes of echocardiography to determine the EF decline and consequent cardiotoxicity.

Data acquisition

Transthoracic echocardiography was performed by two experienced Cardio-oncologists with at least 5 years of experience in this field, using a Phillips EPIQ7c ultrasound system. In instances of interobserver variability, the consensus among the observers resolved the conflicts. Common views utilized in echocardiographic imaging included short-axis and 4-chamber views.

LVEF was measured using the modified Simpson’s biplane method41. Simpson’s biplane method estimates left ventricular volumes by tracing the endocardial borders from apical two- and four-chamber views. The ventricle is conceptually divided into multiple disks, and the volume of each disk is calculated by measuring the area of the traced borders; these individual volumes are then summed to determine both the end-diastolic and end-systolic volumes. Finally, the ejection fraction is computed by subtracting the end-systolic volume from the end-diastolic volume and dividing the result by the end-diastolic volume.

Data stored in the Picture Archiving and Communication System (PACS) is used by an expert Cardio-oncologist and validated by an experienced echocardiologist. In addition to the patient’s ECG characteristics, various echocardiographic parameters related to the heart valves, heart chambers, and myocardium during systole and diastole, including left and right ventricular and atrial volumes, were evaluated and recorded at each time point of imaging.

All patients underwent echocardiography immediately after completion of chemotherapy and also 12 months later. This evaluation was performed with the aim of assessing cardiac function and identifying any potential late cardiotoxicity.

Only the end-systole and end-diastole images of patients based on the ECG in the short-axis view and the 4-chamber view were manually selected and segmented. Study participants were divided into two groups: those with cardiotoxicity (41 patients) and those without (59 patients).

Preprocessing and segmentation

Echocardiography images before and after treatment in 4-chamber and short-axis views were extracted. The analysis is performed on cardiac images at end-systole and end-diastolic phases (frames), which were manually selected, segmented, and shown in Fig. 1. The area of the left ventricular myocardium for segmentation was selected by a specialist and identified in the Fig. 1. In addition, gray-level image intensities were normalized between 0 and 1and Eq. 1 defines this normalization.

$$I(x,y)=\frac{{I^{\prime}(x,y) - \hbox{min} (I^{\prime}(x,y))}}{{\hbox{max} (I^{\prime}(x,y)) - \hbox{min} (I^{\prime}(x,y))}}$$
(1)
Fig. 1
figure 1

Demonstrates the segmentation process for the left ventricular end-systolic (A) and end-diastolic (B) phases in the short-axis view. Panels (C) and (D) depict the corresponding left ventricular end-systolic and end-diastolic phases in the 4-chamber view echocardiography images, respectively. *P value <0.05, statistically significant.

After preprocessing and segmenting the images, radiomics features were extracted and fed into various ML models programming languages.

Feature extraction and selection

Following the segmentation of the images, the next crucial step involved feature extraction42, which aimed to identify and extract key characteristics or attributes from the segmented images, taking into account both the end-diastolic and end-systolic frames. This process encompassed a comprehensive array of 2D radiomics features, each contributing unique insights43. Specifically, the feature extraction incorporated prominent techniques such as Haralick, LAWS, wavelet-based texture analysis, SFTA (Segmentation Fractal texture analyze), Tamura, Shape, and power spectrum analysis. These diverse methods together yielded a total of 184 features for both the end-diastolic and end-systolic phases.

In this study, the chosen set of 2D radiomic features played a critical role in capturing essential patterns and textures present in the medical images. The Haralick features44 allowed for the characterization of the textures’ complexity and uniformity, while the LAWS feature45 focused on capturing local anisotropic patterns. On the other hand, the wavelet-based texture analysis enabled the exploration of image details across different scales. Moreover, the SFTA46 method facilitated the identification of significant local structures, while the Tamura features47 emphasized describing the images’ coarseness, contrast, and directionality. Furthermore, in addition to the aforementioned 2D radiomic features, Local Binary Pattern (LBP) features were incorporated into the feature extraction process. LBP48 analysis provided valuable insights into the local texture patterns within the segmented images during the end-diastolic and end-systolic phases, further enriching the characterization of cardiac structures and assisting in identifying potential anomalies.

Additionally, the Shape features were instrumental in quantifying geometric attributes, such as size and compactness, providing valuable information about the morphological characteristics of the regions of interest. Lastly, the power spectrum analysis allowed researchers to evaluate the frequency distribution within the images, aiding in the recognition of periodic patterns or repetitive structures.

This comprehensive suite of 2D radiomic features offered a holistic perspective on the cardiac images during both end-diastolic and end-systolic phases. By extracting and analyzing these 184 features, the study aimed to uncover intricate relationships between the identified characteristics and various cardiac conditions. The results of this feature-rich analysis were expected to significantly contribute to medical imaging and advance our understanding of cardiac health and pathology.

In the quest for optimal feature selection, the feature selection process encompassed several crucial steps. Initially, the Wilcoxon test was employed, with a significance level set at p < 0.05, to evaluate the significance of diverse features. The top 20% of features with the lowest p-values were then selected for further consideration. The sequential forward selection method was employed to refine the feature selection. These meticulous procedures resulted in identifying a set of promising features for the short-axis view, as detailed in Table 3. Similarly, for the 4-chamber view of the left ventricle, Table 3 presents the best-selected features derived from the rigorous feature selection process. These thoughtfully curated feature sets are anticipated to play a crucial role in augmenting the accuracy and effectiveness of subsequent analyses and predictive models. The steps to perform the work are demonstrated in Fig. 2.

Fig. 2
figure 2

Illustrates the sequential actions required to carry out the task. *A, C ES represent end systolic and B, D ED represent end diastolic, for short axis and 4-chamber view respectively).

Machine learning workflow

Images and data were randomly divided into two parts, with 80% of the data used for training and 20% for testing, and a 5-fold cross-validation was employed. The training and testing procedures were repeated 1000 times. Different ML algorithms, including K-nearest neighbor (KNN) with K = 13, Support vector machine (SVM), Random Under-Sampling Boosted (RUS), and Random Forest (RF), were implemented to perform better analysis and prediction49.

Furthermore, we performed a Permutation-based Feature Importance Test (PermFIT) to strengthen the statistical validity of our findings. This rigorous test allowed us to assess the significance of our results by comparing them to a large number of randomly generated samples. Notably, a p-value of less than 0.001 was considered as the threshold for establishing meaningful statistical significance. This approach ensured that our conclusions were robust and reliable, reducing the likelihood of drawing spurious conclusions based on chance. The SHapley Additive exPlanations (SHAP) value serves as a powerful tool to assess the influence of various features on the outcome of a predictive model. It achieves this by quantifying the contribution of each feature to the final prediction, thereby providing a clearer and more transparent understanding of ML models. With the aid of SHAP values, we could interpret the significance of different features, unraveling the inner workings of the model and its decision-making process50.

Ethical considerations

This retrospective study analyzed de-identified medical data that had been previously collected during routine patient care. The study protocol was approved by the ethical committee of Iran University of Medical Sciences with code number IR.IUMS.FMD.REC.1401.143. Informed consent was waived and privacy and confidentiality of their information were maintained by removing all protected health information and assigning anonymized data.

Result

The study group comprised 100 participants, with the majority being female (84%) and the remaining 16% identified as male. The mean age of the participants was 54.53 ± 13.72 years, and the mean body mass index (BMI) was 26.24 ± 4.44 Kg/m. Prevalence of comorbidities was included diabetes mellitus in 18% of participants, hypertension in 33%, dyslipidemia in 25%, smoking in 9%, and alcohol consumption in 0% (Table 1).

Table 1 Patients’ demographic and comorbidity characteristics.

Table 2 provides the more detailed imagining findings of the echocardiography of the patients among the two groups. Most of the imaging variables were similar between the groups.

Table 2 Bassline echocardiographic findings of the patients among the two cardiotoxicity and non-cardiotoxicity groups.

Table 3 provides a concise summary of selected features and their corresponding categories for both short-axis and 4-chamber views of patients. The features are categorized based on their types.

Table 3 Selected features and their categories for the short-axis and 4-chamber view of the patients.

Effectiveness of different machine learning models

In this study, using various ML algorithms, accuracy, sensitivity, specificity, precision, and F1 scores were assessed for each of the short axis and 4 chamber views of the left ventricle separately and for both views.

Among the 100 patients exclusively assessed with a short-axis view, the KNN and linear SVM models emerged as the most effective, achieving accuracies of 0.92 and 0.90, respectively. The best-reported outcome was 92%, whose values for each parameter in short axis view are reported in Table 4. The training and testing procedures with random sampling were repeated 1000 times.

Table 4 Performance metrics, including accuracy (ACC), sensitivity (SEN), specificity (SPE), precision (PR), false positive rate (FPR), F1 scores and ROC curve (AUC), for all models in the context of the short axis view.

Table 5 presents performance metrics for models in the context of 4-chamber views. Notably, in the 4-chamber view, the SVM model exhibits a high accuracy of 88%, achieving a perfect precision of 1.00 and an F1 score of 0.80. Additionally, the KNN model demonstrates strong overall performance with an accuracy of 83%, a precision of 0.89, and an F1 score of 0.72. These results highlight the effectiveness of these models in assessing both short-axis and 4-chamber views, providing valuable insights for potential clinical applications.

Table 5 Illustrates performance metrics, including accuracy (ACC), sensitivity (SEN), specificity (SPE), precision (PR), false positive rate (FPR), F1 scores and ROC curve (AUC), for all models in the context of the 4-chamber view.

Table 6 its illustration the reported results are based on the mean of a 5-fold cross-validation. However, if the experiment is repeated, the results may vary due to the inherent randomness introduced by data shuffling.

Therefore, we did not conduct an extensive comparison between models. Instead, the various models highlight the power of radiomics, and the analysis of the permutation test confirms that the results are not due to chance. have implemented the DeLong test, which provides the p-values for pairwise comparisons between models. we have included the Area Under the ROC Curve (AUC) for 4chamber and values for each classifier as follows: KNN (N = 13) – 0.5896, SVM – 0.6801, RUSboosted – 0.5059, and Random Forest (RF) – 0.4649. the Area Under the ROC Curve (AUC) values for the classifiers on the short-axis view are as follows: KNN (N = 13) – 0.6919, SVM – 0.7637, RUSboosted – 0.5844, and Random Forest (RF) – 0.5983.

Table 6 Shows p-values for all AUC values which will be the main metrics for 4-chamber and short axis views.
Fig. 3
figure 3

Histogram representation of the results for PermFIT in the (a) 4-chamber and (b) short-axis view. The test was conducted by repeating it 1000 times with the correct label and another 1000 times with a random label. The horizontal axis represents accuracy (AUC), while the vertical axis denotes the frequency of result repeat over 1000 instances of correct labeling and 1000 instances of random labeling.

Figure 4 display influence the mean SHAP values of selected characteristics in short-axis samples in the normal and cardiotoxic classes. For class 0, which represents the healthy group (non-cardiotoxic), according to Fig. 4, Features SFTA3(ES), Tamura2(ES), and Wavelet (ES) are each most important to determine the toxicity or non-toxicity of each group.

Fig. 4
figure 4

Influence of features for the short-axis view on the normal classes and cardiotoxicity as determined by SHAP values.

Figure 5 shows the effect of the characteristics on the cardiotoxic and normal classes for the 4-chamber view using the average SHAP values. Features Wavelet1(ES), Wavelet 2(ES), and Shape 1 (ED) represent the most effective characteristics in the cardiotoxic group.

Fig. 5
figure 5

The impact of features for the 4-chamber view on normal and cardiotoxic classes, as determined by SHAP values.

Discussion

The present study encompassed 100 participants, predominantly female (86%), with an average age of 54.53 ± 13.72years. It aimed to employ interpretable machine learning techniques to predict cardiac toxicity following chemotherapy in cancer patients, utilizing echocardiographic imaging data. The objective was to gain insights into the intricate interplay between cancer treatment and cardiovascular complications within this patient population. The study design involved the analysis of echocardiography images obtained before and after chemotherapy administration to evaluate its impact on cardiac function. Parameters such as LVEF were assessed, and predictive models for chemotherapy-induced cardiotoxicity were developed. Additionally, feature extraction and selection methods were applied, with the significance of the extracted features validated through techniques such as SHAP and PermFIT testing.

In a systematic review51, various research studies were reviewed which demonstrated several prevalent prognostic factors emerged, including age, initial left ventricular ejection fraction, hypertension, and diabetes. Moreover, scrutiny of four constructed models revealed significant apprehensions regarding bias susceptibility, notably concerning sample size, management of missing data, and the absence of suitable performance metric. An investigation18 conducted retrospectively examined the predictive capabilities of ML algorithms in a cohort of 4309 patients with cancer. The study focused on leveraging clinically relevant variables for prediction purposes. Results yielded a range of area under the curve (AUC) values, spanning from 0.660 to 0.882, indicative of varying predictive performance across different models. Noteworthy variables associated with CTRCD were identified through the analysis, encompassing factors such as age, hypertension, glucose levels, LVEF, creatinine levels, and aspartate aminotransferase levels. In a study akin to our investigation24, a range of parameters encompassing clinical, chemotherapy, and echocardiographic variables were employed to construct a RF model aimed at prognosticating chemotherapy-induced cardiac dysfunction and Heart failure with reduced ejection fraction (HFrEF). The study entailed a comprehensive evaluation of the cardiac impact of chemotherapeutic agents over a 3-year follow-up period. The Multi-Layer Perceptron (MLP) model emerging as the most effective in predicting CTRCD, yielding an AUC of 0.66, accompanied by sensitivity and specificity rates of 0.86 and 0.53, respectively. However, it is imperative to note that these performance metrics are notably lower compared to the findings of our own study. In a comparable investigation conducted by MARTINS et al.52, the focus was on breast cancer patients undergoing anthracycline chemotherapy, with the utilization of the Extreme Gradient Booster (XGB) model to predict cardiotoxicity. Notable echocardiographic variables such as MPI (Myocardial Performance Index), ESV (End Systolic Volume), EDV (End Diastolic Volume), and SBP (sub-bottom profiler) emerged as significant predictors in their analysis. The XGB model demonstrated commendable performance, achieving an accuracy of 0.89 and an AUC of 0.91. Variable importance was assessed using the SHAP approach in their study. While bearing similarities to our present investigation in terms of accuracy, it is worth noting the differences in methodology. In our study, we opted for the PermFIT53 for variable importance assessment. Additionally, our study diverges from the aforementioned one in terms of parameter selection. While the previous study solely relied on echocardiography parameters, our approach incorporated radiomic features, which are inherently more consistent due to their automatic nature and are less susceptible to environmental errors such as user-dependency and inter-observer variability.

Figure 3 illustrates the outcomes of the PermFIT test designed to evaluate the model’s accuracy. In Fig. 3a, the histogram distributions depict that the chance-level accuracy is concentrated around 0.49, whereas the model achieves an accuracy centered around 0.85 in the 4-chamber view. Additionally, Fig. 3b displays the PermFIT test results for the short-axis view, where the chance-level is approximately 0.76, and the model’s accuracy is around 0.88. These results imply that the model’s accuracy significantly exceeds the chance level, with a more pronounced effect observed in the 4-chamber view compared to the short-axis view, emphasizing its efficacy in the specified context.

The SHAP method investigates a local approximation to the predictions of regression or classification models, ensuring faithfulness and interpretability. Enhancing the understanding of the model’s decision-making process54. A SHAP analysis was performed in Figs. 4 and 5 to assess the significance of features in short-axis and 4-chamber views across normal and cardiotoxic classes. This analysis elucidates the impact and relevance of selected features within the classification model for different classes. Figure 4 provides valuable insights into how various features influence the model’s predictions in short-axis view. Among the radiomic features in the short-axis view, end-systolic SFTA and HOG exhibited the most substantial impact on the cardiotoxic and normal classes, respectively. Conversely, end-systolic SFTA and Tamura had minimal influence on the model’s prediction for the normal class. Additionally, end-systolic Frequency demonstrated low values for the cardiotoxic class, signifying its limited impact. Alternatively, for the normal class, end-systolic HOG and SFTA were the most influential, while end-systolic SFTA and Tamura had the least impact on predictions. In the cardiotoxic class, end-systolic SFTA and Tamura had the most significant impact, while end-systolic Frequency and end-systolic SFTA and LAWS had the least effect on predictions. In the 4-chamber view (Fig. 5), end-systolic Wavelet and end-diastolic Laws had the most and least impact on predictions, respectively, in the cardiotoxic group. In the normal group, end-diastolic shape and Laws had the highest and lowest SHAP values. Generally, in the short-axis view, most features pertain to end-systolic features, whereas in the 4-chamber view, end-systolic and end-diastolic features contribute equally, suggesting a weaker influence of end-diastolic features in the short-axis view. Notably, in the 4-chamber view, the highest values are associated with the cardiotoxic class, underscoring the positive effects of features in the cardiotoxic class. In the present study, we employed the SHAP approach to identify selected features’ value and importance. ML techniques can effectively capture intricate nonlinear connections. However, ML models’ inherent complexity and “black box” nature pose challenges in interpreting their outputs, limiting their applicability in this domain.

Limitations

Financial and specific data unavailability, we had severe limitations in data acquisition and the conduction of the study due to financial and specific data unavailability. In addition, due to limited resources, we could not assess the prediction model based on external validation and used cross-validation with our self-data. Furthermore, 3D echocardiography with more accurate and precise parameters could be more reliable than 2D echocardiography. Furthermore, concerning personalized medicine and individual treatment plans for each patient, as well as dose adjustments and choice medication based on the patients’ medical conditions, some heterogeneity was expected in the sample population. however, on average, all patients underwent standard chemoradiation therapy in accordance with the guidelines.

Future prospects

Based on our findings, future research could focus on larger, multi-center studies to validate and generalize our results, ensuring broader applicability. Additionally, integrating deep learning with radiomics could enhance predictive accuracy by capturing subtle features in echocardiographic images, while exploring early biomarkers for cardiotoxicity could enable earlier detection before measurable changes in LVEF occur. Future studies should also aim for personalized risk stratification, combining radiomics, clinical factors, and genetic data, to tailor chemotherapy and monitoring to individual patients. Long-term follow-up studies would further help understand the impact of early prediction on both cardiac health and cancer outcomes, advancing our approach to managing chemotherapy-induced cardiotoxicity.

Enrolling more related parameters like ECG and paraclinical laboratory data and use more sample sizes is suggested in future studies to achieve more sensitivity and specificity. Also, adding strain analysis (GLS, GRS and GCS) to the present parameters could enhance the accuracy of the prediction model. In the present study, we exclusively used imaging modalities with some demographic characteristics. Of course, it can be considered a strength point because of the limited resources needed.

Conclusion

This study underscores the potential of ML in enhancing cardiac toxicity diagnosis, particularly in the context of short-axis echocardiography views. Given the importance of early detection, we advise clinicians to incorporate advanced imaging-based predictive models, such as ML-driven radiomics, into cardiac monitoring measures for chemotherapy patients, at least in some high-risk patients, if not all. These approaches may help identify early signs of cardiotoxicity, enabling timely interventions and personalized treatment adjustments. Future studies with larger cohorts will be necessary to validate these findings and further optimize risk stratification in clinical practice. The study faced limitations due to financial and data unavailability, limited resources, and cross-validation. 3D echocardiography could be more reliable than 2D echocardiography. Future studies should include more parameters and larger sample sizes to improve sensitivity and specificity. The study used imaging modalities with demographic characteristics, which could be a strength due to limited resources.