Table 7 Ablation experiments on the TUS dataset.
From: Attention residual network for medical ultrasound image segmentation
 | mIOU(%) | F1(%) | Accuracy(%) |
---|---|---|---|
U-Net | 65.89 | 77.17 | 94.51 |
U-Net+Residual connection | 76.25 | 85.10 | 95.56 |
U-Net+Residual connection+Attention block | 79.31 | 86.60 | 96.42 |
ARU-Net | 84.82 | 91.30 | 97.73 |