Table 12 Confirmation test.

From: Optimization of tribocorrosion performance for SUS casted AZ91D Mg composites reinforced with ZrB2 using an entropy integrated TODIM approach

Parameter Setting

Initial Parameter

Optimal Parameters

Experimental Values

Improvement in response values

Level

A3B1C4D2

A = 14.9%, B = 229 oC

C = 30.50 N, D = 9.99

TODIM Grade

0.566

0.904

0.338

Corrosion

Potential (V)

-1.701

-1.39

0.311 (improvement, less negative is better)

Corrosion

Current (A/cm2)

0.016

0.005

0.011

Corrosion

Rate (mm/yr.)

2.22

0.964

1.256

Wear Depth (µm)

353.5

249.62

103.88

Hardness after Tribocorrosion (HV)

94.81

100.94

6.13