Table 3 Comparison of accuracy and false alarm counts per 1,000 patients between TEWS and MEWS with similar sensitivity.
Sensitivity, % (95% CI) | Specificity, % (95% CI) | PPV, % (95% CI) | NPV, % (95% CI) | False alarm counts per 1,000 patients (95% CI) | |
---|---|---|---|---|---|
Vasopressor use | |||||
MEWS ≥ 5 | 49.0 (46.6–51.5) | 96.8 (96.7–96.9) | 18.6 (17.5–19.8) | 99.2 (99.2–99.3) | 32 (30.4–32.6) |
TEWS ≥ 0.983 | 49.6 (47.1–51.9) | 99.5* (99.5–99.5) | 56.6* (53.9–59.2) | 99.3* (99.3–99.4) | 5* (4.6–5.4) |
Respiratory support | |||||
MEWS ≥ 5 | 37.1 (34.4–40.0) | 96.4 (96.3–96.5) | 9.5 (8.6–10.4) | 99.3 (99.3–99.4) | 35 (34.3–36.5) |
TEWS ≥ 0.975 | 38.5 (35.9–41.4) | 99.0* (98.9–99.0) | 25.3* (23.2–27.3) | 99.4* (99.4–99.5) | 10* (9.7–10.8) |
ICU admission | |||||
MEWS ≥ 5 | 29.1 (27.2–30.9) | 96.5 (96.4–96.6) | 15.3 (14.3–16.3) | 98.4 (98.4–98.5) | 34 (33.0-35.2) |
TEWS ≥ 0.921 | 29.1 (27.3–31.0) | 98.7* (98.6–98.8) | 29.7* (27.9–31.6) | 98.7* (98.6–98.7) | 13* (12.2–13.4) |
Septic shock | |||||
MEWS ≥ 5 | 53.4 (50.5–56.4) | 96.6 (96.5–96.7) | 13.2 (12.3–14.2) | 99.5 (99.5–99.6) | 34 (32.5–34.6) |
TEWS ≥ 0.976 | 54.3 (51.2–57.2) | 99.3* (99.2–99.3) | 38.0* (35.3–40.4) | 99.6* (99.6–99.7) | 7* (6.8–7.8) |
Cardiac arrest | |||||
MEWS ≥ 5 | 38.2 (29.7–46.6) | 96.0 (95.9–96.1) | 1.1 (0.8–1.4) | 99.9 (99.9–99.9) | 40 (38.6–41.0) |
TEWS ≥ 0.872 | 38.9 (30.4–47.3) | 97.8* (97.8–97.9) | 1.8* (1.3–2.3) | 100.0* (99.9–100.0) | 22* (20.8–22.3) |