Table 3 LVEN and ChP surface areas, volumes, and signal intensity in supine and upright scans.

From: Assessing morphological changes in the choroid plexus between standing and supine positions using a rotatable MRI system

Index

Posture

Value

Relative difference

P-value

LVEN surface area (mm2)

Supine

7849.84\(\:\pm\:\)1888.31

-1.24%

0.230

Upright

7757.21\(\:\pm\:\)1957.08

ChP surface area (mm2)

Supine

1134.57\(\:\pm\:\)358.36

-5.30%

0.021

Upright

1060.58\(\:\pm\:\)328.85

LVEN volume (mm3)

Supine

12224.19\(\:\pm\:\)11782.20

-1.66%

0.360

Upright

12042.91\(\:\pm\:\)4907.95

ChP volume (mm3)

Supine

963.66\(\:\pm\:\)327.88

-7.53%

0.002

Upright

878.29\(\:\pm\:\)296.81

ChP signal (a.u.)

Supine

0.56\(\:\pm\:\)0.08

11.46%

< 0.001

Upright

0.62\(\:\pm\:\)0.07

  1. * Values in bold font represent they are statistically significant (P < 0.05).