Table 3 A comparative summary of the anode electrodes in double-chamber microbial fuel cells.
Anode material | Inoculation source | Surface area | Power density | Current density efficiency | References |
---|---|---|---|---|---|
G/PEDOT/ CP | Escherichia coli | 22.5 cm2 | 873 mW/ m2 | 3.59 mA/m2 | |
Fe3O4/AC/SSM | Pre-acclimated Effluent | 7 cm2 | 809 mW/m2 | 5.51 A/m2 | |
GO-PANI | Synthetic waste water | 0.0071 m2 | 1.1 mW/m2 | 87.71 mA/m2 | |
Graphite activated | Mix culture | 3.14 m2 | 0.560mW/m2 | 250 mA/m2 | |
graphite rods | Synthetic water | 10 × 2 cm | 0.71 mW/ m2 | 87.71 mA/m2 | |
L-GO/ZnO/Gr | Pd (II) ion-supplemented wastewater | 76.0 cm2 | 1.350 mW/m2 | 142.98 mA/m2 | |
E-rGO/Gr | Cr(VI) and Pd (II) ion-supplemented waste water | 40.0 cm2 | 8.75 mW/ m2 | 609 mA/ m2 | This work |
E-rGO/Fe3O4/Gr | Cr(VI) and Pd (II) ion-supplemented waste water | 40.0 cm2 | 39.77 mW/ m2 | 1171 mA/ m2 | This work |