Table 13 Exergy analysis of simultaneous recuperator cycle with ORC.

From: 3E analysis of sCO2 recuperator cycle with multi effect desalination and organic Rankine cycle to enhance environmental sustainability

Component

(R-123)

(R-245FA)

(R-600)

Exergy

Exergy destruction

Exergy

Efficiency

Exergy

Exergy destruction

Exergy

Efficiency

Exergy

Exergy destruction

Exergy

Efficiency

(kw)

(kw)

%

(kw)

(kw)

%

(kw)

(kw)

%

sCO2 Turbine

12,388

650.7

4.03

94.75

12,388

650.7

3.90

94.75

12,388

650.7

3.82

94.75

sCO2 Pump

1979

430.3

2.67

82.14

1979

430.3

2.58

82.14

1979

430.3

2.53

82.14

sCO2 Recuperator (H/C)

9126/6752

2366

14.65

74.07

9126/6759

2366

14.20

74.07

9126/6759

2366

13.89

74.07

sCO2 Condenser

695.2

695.2

4.31

80.88

695.2

695.2

4.17

80.88

695.2

695.2

4.08

80.88

sCO2 HRSG

13,470

2713

16.08

78.89

13,470

2713

16.27

78.89

13,470

2713

15.93

78.89

ORC Turbine

1736

122.4

0.76

92.95

1170

80.5

0.48

93.12

776.3

52.23

0.31

93.27

ORC Pump

12.85

3.13

0.02

80.42

9.91

2.42

0.01

80.35

8.15

1.99

0.01

80.35

ORC Condenser

1054

1054

6.53

39.55

1306

1306

7.84

33.23

1520

1520

8.92

29.34

ORC HRSG

277

8113

50.24

70.34

2466

8424

50.54

62.45

2288

8602

50.51

57.95

CYCLE

-

16,148

100

72.21%

-

16,668

100

68.86%

-

17,032

100

66.53%