Table 2 Specific heat capacity at constant pressure for smoke flow in the stack.

From: 3E analysis of sCO2 recuperator cycle with multi effect desalination and organic Rankine cycle to enhance environmental sustainability

Node

Temperature

Pressure

Fluid

\(\:{\varvec{c}}_{\varvec{p}}\:\)Taverage

(kJ/kg k)

\(\:{\varvec{c}}_{\varvec{p}}\:\)Tinlet

(kJ/kg k)

\(\:{\varvec{c}}_{\varvec{p}}\:\)Toutlet

(kJ/kg k)

\(\:{\varvec{c}}_{\varvec{p}}\:\)Constant

(kJ/kg k)

(°C)

(bar)

13

459

1

Air (Smoke)

1.040

1.082

1.009

1.148

15

90

1