Table 8 The proposed optimal points based on EHC and desirability function.
Weight | Optimal Inputs | Objectives | Desirability | ||||
---|---|---|---|---|---|---|---|
TC | DV | T (°C) | MF (%) | MXene ratio | TC | DV | |
0.50 | 0.50 | 60 | 2 | 0.077 | 1.100 | 0.955 | 0.830 |
0.75 | 0.25 | 60 | 2 | 0 | 1.114 | 0.991 | 0.905 |
0.25 | 0.75 | 60 | 1.802 | 0.5 | 0.927 | 0.751 | 0.816 |