Table 6 Performance comparison of converter configurations of MOSMPS at full load.

From: Field programmable gate array-based neural network control strategy for computer power supply applications

Converter

Settling

Time (s) (at V01)

NN control (at V01)

Conventional control

(at V01)

NN*

PI*

%Overshoot

%Undershoot

%Overshoot

%Undershoot

SEPIC

0.19

0.23

2.03

2.10

2.55

2.82

CSC

0.25

0.30

2.52

2.61

3.50

3.89