Table 7 Comparison of simulation and hardware results of MOSMPS at rated supply voltage.
Bridgeless SEPIC converter-based MOSMPS | 100% load condition | 50% load condition | ||||||
---|---|---|---|---|---|---|---|---|
PF | % THD of Iin | PF | % THD of Iin | |||||
NN* | PI* | NN* | PI* | NN* | PI* | NN* | PI* | |
Simulation results | 0.991 | 0.91 | 2.90 | 5.32 | 0.980 | 0.82 | 3.85 | 5.85 |
Experimental results | 0.999 | 0.801 | 2.818 | 8.034 | 0.99 | 0.888 | 2.834 | 7.726 |