Table 1 Parameters and specifications used in this work.

From: Precision measurement and sustainable assessment in milling of additively manufactured TiC–Ti64-ELI composites

Milling machine

COSMOS

Workpiece

TiC–Ti64-ELI

Insert (tool) coating

PVD-TiAlN

Insert model

1135PDER (APMT)

Nose radius

0.8 (mm)

Vc

30–60 (m/min)

fr

0.08–0.10 (mm/rev)

Radial DOC

12 (mm)- (ae)

Axial DOC

0.5 (mm)- (ap)

Distance of cut

50 mm (2 passes)