Table 4 BCVA and retinal sensitivity difference based on the location and type of drusen.

From: Influence of subretinal drusenoid deposit on retinal sensitivity in age-related macular degeneration

 

Presence of SDD

Presence of SD

Cases with SDD

Cases with SDD

SDD (−)

SDD (+)

P val

SD (-)

SD ( +)

P val

macula (-)

macula ( +)

P val

dot type

ribbon type

P val

Number of eyes

82

220

 

79

223

 

94

150

 

113

69

 

logMAR VA

0.18 (0.15)

0.17 (0.16)

0.827

0.17 (0.18)

0.18 (0.15)

0.769

0.18 (0.16)

0.18 (0.17)

0.997

0.17 (0.18)

0.18 (0.15)

0.773

Avg. RS

20.87 (4.45)

19.11 (5.36)

0.009*

19.29 (5.82)

19.69 (4.94)

0.558

20.32 (5.34)

19.05 (5.3)

0.073

20.18 (4.45)

17.08 (6.67)

 < 0.001*

Ring 1 Avg. RS

20.43 (4.6)

17.64 (5.83)

 < 0.001*

17.48 (6.33)

18.73 (5.37)

0.092

19.77 (5.47)

17.45 (5.86)

0.002*

18.68 (5.03)

15.61 (6.91)

0.001*

Ring 2 Avg. RS

21.32 (4.48)

19.36 (5.42)

0.004*

19.81 (5.63)

19.92 (5.12)

0.87

20.72 (5.19)

19.37 (5.38)

0.056

20.4 (4.71)

17.58 (6.43)

0.001*

Ring 3 Avg. RS

21.01 (4.74)

20.4 (5.3)

0.36

20.73 (5.85)

20.51 (4.89)

0.749

20.63 (5.79)

20.41 (5.07)

0.757

21.49 (4.15)

18.27 (7.0)

 < 0.001*

S4 RS

19.87 (5.29)

19.42 (5.72)

0.543

19.32 (6.58)

19.62 (5.22)

0.677

19.44 (6.28)

19.42 (5.74)

0.984

20.5 (4.98)

17.06 (7.15)

 < 0.001*

  1. logMAR VA, logarithm of the minimum angle of resolution visual acuity; macula (−), not involving macular region; macula (+), involving macular region.
  2. Ring 1, 2 and 3 comprised of 12 measure points at 5-, 3- and 1-degree radius circle centered at fovea, respectively. S4 is a measure point at fovea.
  3. Avg., average, RS, retinal sensitivity.
  4. P val: P value.
  5. *: P value < 0.05.