Table 3 Physical properties of cement.

From: Smart monitoring of composite concrete damage using EMI technique with temperature effects compensation and ANN integration

S No.

Name of the test

Value

1.

compressive strength

M60

M65

7 days − 24.67 MPa 28 days-43.33 MPa

7 days − 24.67 MPa

28 days − 43.33 MPa

2.

Consistency

31%

3.

Fineness of cement

4.1%

4.

Specific Gravity

3.14(g/cm3)

5.

Soundness

3.1 mm

6.

Initial Setting Time-(IST)

64 min

7.

Final Setting Time-(FST)

445 min