Table 2 Fracture load, fracture mode, and abutment deformation results from the in vitro testing of the T-bridge design.

From: Effects of restorative material on the mechanical performance of three-unit implant-supported fixed dental prostheses with bilateral cantilevers: an in vitro study

T-Bridge

PMMA-based polymer

Resin composite

PEEK

5Y-TZP ceramic

3Y-TZP ceramic

Median fracture load (IQR) [N]

1250 (377)

1771 (412)

2333 (1291)

2960 (832)

5108 (1415)

Stat. comparison

AB

C

D

A

BC

Median fracture mode (IQR) (n)

1.5 (1)

2.0 (0.75)

0.0 (0)

2.0 (0)

2.0 (0)

Stat. comparison

A

B

ABCD

C

D

Deformation

0

0

9

9

10

No deformation

10

10

1

1

0

Stat. comparison

ABC

DEF

AD

BE

CF

  1. Identical capital letters indicate statistically significant differences (to be read horizontally).
  2. IQR, interquartile range; N, Newtons; n, sample size; PEEK, Polyether Ether Ketone; Stat., statistical.