Table 1 Materials used in the study.

From: Effect of sulfinate salt on bonding and polymerization of adhesive to intracoronally bleached dentin

Material

Batch number

Composition

Application

Clearfil SE Bond 2,

AP0439

PRIMER

1. Apply PRIMER and leave for 20 s. Do not rinse

Kuraray Noritake Dental, Tokyo, Japan

 

10-MDP, HEMA, Hydrophilic aliphatic dimethacrylate, dl-Camphorquinone, Water

2. Dry with mild airflow for 5 s

 

AC0904

BOND

3. Apply BOND, make a uniform bond film using a gentle airflow

  

10-MDP, HEMA, Bis-GMA, Hydrophobic aliphatic dimethacrylate, dl-Camphorquinone, Initiators, Accelerators, Silanated colloidal silica

4. Light cure for 10 s

Clearfil DC Activator,

2N0014

Arylsulfinate salt, Accelerators, Ethanol

1. Apply activator and wait for 5 s

Kuraray Noritake Dental, Tokyo, Japan

2. Dry with mild air for 5 s

Clearfil AP-X Flow, Kuraray Noritake Dental, Tokyo, Japan

730,360

TEGDMA, hydrophobic aromatic dimethacrylate, silanated barium glass, silanated colloidal silica

1. Apply resin composite in thickness 2 mm per increment

2. Light cure for 10 s

  1. 10-MDP Methacryloyloxydecyl dihydrogen phosphate, TEGDMA Triethylene glycol dimethacrylate, HEMA 2-Hydroxyethyl methacrylate, BisGMA Bisphenol A diglycidylmethacrylate.