Table 4 Optimized drilling parameters recommended for bits’ size 12.25” in the Majnoon Field for (Dammam, UER, Aaliji, Shiranish, Hartha, Sadi, Tanuma, and Khasib) formations.
Drilling parameters | North of the field | South of the field | ||||
---|---|---|---|---|---|---|
Minimum | Maximum | Average | Minimum | Maximum | Average | |
WOB (klbs) | 1 | 43 | 15.34 | 1 | 38 | 16.64 |
Surface RPM | 1 | 72 | 58.154 | 1 | 76 | 47.51 |
Total RPM | 113 | 194 | 179.22 | 1 | 199 | 167.73 |
MW (ppg) | 9.3 | 10.7 | 10.052 | 9.3 | 10.8 | 10.166 |
SPP (psi) | 1553 | 2833 | 2465.51 | 1743 | 3071 | 2595.45 |
Torque (ft-lb) | 10,333 | 13,108 | 12441.65 | 0 | 16,645 | 7970.44 |
Flow Rate (gpm) | 512 | 940 | 753.45 | 584 | 744 | 681.21 |