Table 3 Transient and steady-state analysis results for WP with both strategies.

From: Using new control strategies to improve the effectiveness and efficiency of the hybrid power system based on the battery storage system

Strategies

WS (m/s)

Rise time (s)

RT (s)

MPP (W)

SSE

P&O-MPPT technique

9

0.01

0.07

2.63

0.19

11

0.05

0.16

3.51

0.16

12

0.043

0.2

3.93

0.05

ANN-MPPT technique

9

0.009

0.03

2.81

0.01

11

0.01

0.05

3.66

0.02

12

0.0068

0.08

3.992

0.008

Ratios (%)

9

10

57.14

6.4

94.47

11

80

68.75

4

87.5

12

99.32

60

1.5

60