Table 5 Study the extent to which the THD value changes in the two tests.
DPC | DPC-FOTOSMC | ||
|---|---|---|---|
THD (%) | Test 1 | 0.85 | 0.49 |
Test 2 | 1.69 | 1.16 | |
Test 2-Test 1 | 0.84 | 0.67 | |
(Test 2-Test 1)/Test 2 | 49.70% | 57.76% | |
Amplitude fundamental signal (A) | Test 1 | 2267 | 2264 |
Test 2 | 2367 | 2314 | |
Test 1-Test 2 | + 100 | + 50 | |
(Test 1-Test 2)/Test 1 | 4.22% | 2.16% | |