Table 6 Input values used for the model 2 system model53,54.
Parameter | Value | |
---|---|---|
GT cycle | Compression ratio | 9.2 |
Air mass flow rate, kg/s | 438 | |
GTIT, °K | 1350 | |
Ambient temperature, K | 306 | |
LHV of fuel (kJ/kg) | 50,056 | |
\(\:{{\upeta\:}}_{AC}\), % | 80 | |
\(\:{{\upeta\:}}_{GT}\), % | 90 | |
RH | 0.63 | |
RC cycle | HPST inlet pressure, bar | 100 |
IPST inlet pressure, bar | 40 | |
LPST inlet pressure, bar | 10 | |
Condenser temperature, °K | 313 | |
\(\:{{\upeta\:}}_{ST}\), % | 90 | |
\(\:{{\upeta\:}}_{Pumps}\), % | 85 | |
Solar field and TES system | Latitude location (deg.) | 35.47° N |
Longitude location (deg.) | 44.39° E | |
Location | Kirkuk/Iraq | |
Solar field area (m2) | 510,120 | |
HTF outlet temperature (°K) | 840 | |
HTF inlet temperature (°K) | 560 | |
Working fluid | Salt(60%NaNo3-40%KNo3) | |
\(\:{{\upeta\:}}_{PTC}\) | 85 | |
ARS | Generator temperature (°K) | 361 |
Condenser temperature (°K) | 312 | |
Absorber outlet temperature (°K) | 321 | |
SHE effectiveness (%) | 53 | |
Evaporator temperature (°K) | 278 | |
Evaporator inlet air temperature (°K) | 323 | |
Evaporator outlet air temperature (°K) | 283 | |
Condenser inlet water temperature (°K) | 298 | |
Condenser outlet water temperature (°K) | 308 | |
Absorber inlet water temperature (°K) | 298 | |
Absorber outlet water temperature (°K) | 308 | |
LiBr solution | Solution strength (%) | 53 |