Table 7 Output quantities produced by the integrated system models.

From: Performance analysis of integrated solar and natural gas combined cycle power plants in high solar potential regions

Output quantity

Model 1

Model 2

Power supplied to ACs, MW

153.6

140.9

Power output of GTs, MW

260.5

260

Power output of HPST, MW

28.291

28.429

Power output of IPST, MW

30.557

30.707

Power output of LPST, MW

60.534

60.830

Power supplied to P1, kW

102.8

103.3

Power supplied to P2, kW

357.5

359.2

Power supplied to P3, kW

842.2

846.3

Work Net by the system, MW

230

242.7

Overall energy efficiency, %

59.35

59.25

Overall exergy efficiency, %

57.31

57.21