Table 5 The mean temperature difference in the whole volume between the reconstructed temperature maps obtained from the different methods and the ground truth.
Type of undersampling | Undersample | Fourier-PDNet | Fourier-PDUNet |
|---|---|---|---|
1D Varden 25% | 1.221 ± 0.035 | 0.637 ± 0.016 | 0.641 ± 0.018 |
2D Varden 25% | 1.296 ± 0.031 | 0.596 ± 0.014 | 0.657 ± 0.019 |
2D Varden 10% | 1.299 ± 0.032 | 0.618 ± 0.016 | 0.643 ± 0.022 |