Table 5 Study of the effect of the amplitude value of fundamental signal (50 Hz) and THD value between the first and second tests for the two approaches.

From: Reducing power ripple for multi-rotor wind energy systems using FOPDPI controllers

 

DPC-PI

DPC-FOPDPI-PWM

THD(%)

Test 1

0.71

0.47

Test 2

1.29

0.84

Test 2–Test 1

+ 0.58

+ 0.37

Ratios (%)

44.96

44.05

Amplitude of fundamental signal (50 Hz)

Test 1

462.80

462.70

Test 2

474.90

474.90

Test 2–Test 1

+ 12.10

+ 12.20

Ratios (%)

2.55

2.57