Table 6 The SSE, response time, overshoots, and ripples ratios of the Ps/Qs (Third test).
From: Reducing power ripple for multi-rotor wind energy systems using FOPDPI controllers
 | Approaches | Ps (W) | Qs (VAR) |
---|---|---|---|
SSE | DPC | 2120 | 2739.25 |
DPC-FOPDPI | 500 | 1551.30 | |
Ratios (%) | 76.42 | 43.37 | |
Ripples | DPC | 6000 | 6472.44 |
DPC-FOPDPI | 3000 | 3663.80 | |
Ratios (%) | 50 | 43.39 | |
Overshoot | DPC | 1730 | 424.90 |
DPC-FOPDPI | 600 | 711.43 | |
Ratios (%) | 65.32 | − 40.28 | |
Response time (ms) | DPC | 0.755 | 0.717 |
DPC-FOPDPI | 1.16 | 1.22 | |
Ratios (%) | − 34.91 | − 41.23 |