Table 6 The SSE, response time, overshoots, and ripples ratios of the Ps/Qs (Third test).

From: Reducing power ripple for multi-rotor wind energy systems using FOPDPI controllers

 

Approaches

Ps (W)

Qs (VAR)

SSE

DPC

2120

2739.25

DPC-FOPDPI

500

1551.30

Ratios (%)

76.42

43.37

Ripples

DPC

6000

6472.44

DPC-FOPDPI

3000

3663.80

Ratios (%)

50

43.39

Overshoot

DPC

1730

424.90

DPC-FOPDPI

600

711.43

Ratios (%)

65.32

− 40.28

Response time

(ms)

DPC

0.755

0.717

DPC-FOPDPI

1.16

1.22

Ratios (%)

− 34.91

− 41.23