Correction to: Scientific Reports https://doi.org/10.1038/s41598-025-24482-x, published online 23 October 2025
The original version of this Article contained an error in the order of the Figures. Figure 5 was published as Figure 1, Figure 6 was published as Figure 2, Figure 1 was published as Figure 3, Figure 2 was published as Figure 4, Figure 3 was published as Figure 5, and Figure 4 was published as Figure 6. The Figure legends were correct.
The original Figures 1, 2, 3, 4, 5, 6 and accompanying legends appear below.
Box plot showing significance levels (p values calculated using Student’s t-test) comparing GTBF, BFD, and BFDcorr measurements for (a) voxels corresponding to the PDAC region, and (b) voxels representing the non-neoplastic pancreatic parenchyma tissue in the DPPs. GTBF = ground-truth blood Flow, BFD = uncorrected blood flow, BFDcorr = corrected blood flow, PDAC = pancreatic ductal adenocarcinoma, DPP = digital perfusion phantom.
A detailed explanation of the output obtained at each step during development of the noise correction algorithm. (a) An arterial input function (AIF) of a digital perfusion phantom (DPP) with zero baseline and temporal sampling rate of 1.5 s, generated by averaging the AIFs from a cohort of 59 pancreatic ductal adenocarcinoma (PDAC) patients. (b) An example of the simulated impulse response function (IRF) of a DPP. (c) An example of noise-free and noise-added tissue attenuation curves (TACs) for a DPP generated for both tissue types, PDAC and non-neoplastic pancreatic parenchyma. (d) An example of TACs from non-neoplastic pancreatic parenchyma and PDAC regions of a PDAC patient for comparison with the simulated TACs. (e) An example of an image from the DICOM series of a DPP made up of 16,128 (28 sets of ground-truth values * 576 random noise samples) TACs. The top right corner of the phantom image represents the AIF. (f) An example of a blood flow (BF) map obtained from a DPP using commercially available CT perfusion software (syngo.via Body perfusion VB10B, Siemens Healthineers).
A flow chart illustrating the complete noise correction process for blood flow (BF) measurements, including evaluation using digital perfusion phantom (DPP) (starting from the first block) and evaluation using a clinical dataset (starting from the second block). For the DPP analysis, each GTBF value is simulated using two independent sets of 576 noise-impacted TACs, resulting in BF1 and BF2 estimates for random error calculation. This process is repeated for 28 GTBF values, totaling 16,128 TACs. For the clinical dataset, patient BF values calculated using the deconvolution model from Mayer’s study18 were used as input for the noise-impacted BF maps. BFD represents the noise-impacted BF measurements, which need to be corrected. IRF is the impulse response function, AIF is the arterial input function, TAC represents the tissue attenuation curve, and GTBF is the ground-truth blood flow. BFDcorr(i) represents the noise-corrected BF measurement for the ith iteration. The random error and model error calculations are also shown in the flow chart. This iterative process for DPP continues until BFDcorr aligns with GTBF or until the error between GTBF and corrected measurements is minimized to an acceptable threshold.
The original Article has been corrected.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Vats, N., Mayer, P., Kortes, F. et al. Correction: Model based noise correction enhances the accuracy of pancreatic CT perfusion blood flow measurements. Sci Rep 16, 5139 (2026). https://doi.org/10.1038/s41598-026-36173-2
Published:
Version of record:
DOI: https://doi.org/10.1038/s41598-026-36173-2