Table 2 Flow cytometry panel used throughout the study

From: A microfluidic bone marrow chip for the safety profiling of biologics in pre-clinical drug development

Laser

Emission detectors

Filters

Fluorophore

T cell co-culture allogenic setup + 1× TfR-binder study

T cell co-culture co-culture autologous setup + 2× TfR-binder study

Lineage differentiation and inflammatory factors+ 1× TfR-binder study

Panel N°

1.

2.

3.

1.

2.

3.

1.

2.

Violet 405nm

V1

450/50

BV421

CD19

CD13

CD69

CD19

CD13

CD69

 

CD14

V2

525/50

BV510

CD45

CD14

HLA-DR

  

HLA-DR

CD19

CD13

V3

579/34

BV570

      

L/D

L/D

V4

615/20

BV605

   

CD45

CD14

   

V5

667/30

BV650

CD34

 

CD3

  

CD3

CD56

CD34

Blue 488nm

B1

525/50

FITC

L/D

L/D

L/D

L/D

L/D + CD3

L/D

CD45

CD45

B2

579/34

PE

CD235a

CD33

CD25

CD235a

CD45

CD25

CD235a

CD15

B5

725/40

PerCP/Cy5.5

 

CD66b

 

CD33

    

B6

785/62

PE-Cy7

CD33

CD16

PD-1

CD10

CD16

PD-1

CD33

CD33

Red 640 nm

R1

667/30

APC/AF647

CD56

CD15

CD8

CD56

CD15

CD8

CD10

CD16

R3

785/62

APC-Cy7

CD71

CD41a

CD4

CD71

CD41a

CD4

CD71

CD41a