Table 1 Percentile distribution of reconstruction error between real and reconstructed ECGs

From: Evaluating the feasibility of 12-lead electrocardiogram reconstruction from limited leads using deep learning

ECG feature

Lead

1-lead reconstruction

2-lead reconstruction

  

5%

10%

90%

95%

5%

10%

90%

95%

RR interval (ms)

 

0

0

2

2

0

0

0

2

QT interval (ms)

 

−10

−8

14

17

−10

−8

12

16

PR interval (ms)

 

−22

−16

14

20

−18

−14

10

14

QRS duration (ms)

 

−16

−12

10

14

−14

−10

10

14

R amplitude (μV)

V1

−229

−175

92

107

−230

−161

68

88

 

V2

−715

−547

146

198

−647

−474

210

273

 

V3

−953

−717

362

479

−923

−658

435

542

 

V4

−1125

−854

542

686

−1049

−796

483

632

 

V5

−823

−630

416

547

−788

−576

303

393

 

V6

−554

−356

415

513

−444

−322

225

273

T amplitude (μV)

V1

−199

−146

142

177

−172

−122

165

194

 

V2

−429

−337

209

269

−332

−240

303

361

 

V3

−412

−318

195

249

−334

−239

268

322

 

V4

−347

−268

152

200

−264

−210

185

229

 

V5

−185

−132

118

156

−148

−102

102

122

 

V6

−122

−83

98

122

−88

−59

68

88

S amplitude (μV)

V1

−547

−443

365

587

−478

−366

303

507

 

V2

−1074

−805

405

538

−959

−713

425

578

 

V3

−917

−733

293

430

−796

−625

391

493

 

V4

−757

−591

185

249

−610

−415

278

348

 

V5

−415

−322

93

126

−283

−191

132

173

 

V6

−170

−126

39

53

−87

−59

68

85

ST amplitude (μV)

V1

−88

−64

49

59

−68

−49

63

74

 

V2

−230

−161

78

98

−171

−117

117

142

 

V3

−195

−141

83

100

−161

−103

102

122

 

V4

−136

−93

63

78

−117

−78

63

78

 

V5

−59

−35

63

73

−44

−30

49

68

 

V6

−49

−34

43

49

−35

−25

39

49

  1. Summary of the 5th, 10th, 90th, and 95th percentiles of the reconstruction error, calculated as the difference between the reconstructed ECG and the original ECG.