Abstract
Purpose
To validate the applicability of a newly developed, noncontact scanning peripheral anterior chamber depth analyzer (SPAC) for screening eyes at the risk of angle-closure glaucoma (ACG).
Subjects and methods
All glaucoma patients who visited the University of Yamanashi Hospital from February through May 2003 were enrolled, except those with aphakic eye or pseudophakic eye. Of the 552 enrolled patients, 48 with ACG or narrow angles requiring laser iridotomy (LI) were categorized as patients with high-risk ACG eyes, and those with open angle were categorized as patients with control eyes. In all, 20 patients with ACG or narrow angles requiring prophylactic LI, who were followed up by an independent private ophthalmic clinic, were enrolled for threshold analysis. Nonophthalmologists measured anterior chamber depth and the averaged values of three measurements were employed for analysis. Threshold analysis and discriminant analysis were employed for determining the sensitivity and specificity of SPAC for diagnosing eyes with high-risk ACG.
Results
SPAC distinguished well the high-risk ACG eyes from the control eyes, and one of the most useful criteria for screening is as follows: any of the four measured points should exceed 95% confidence interval, and sensitivity and specificity should be 97.6 and 83.5%, respectively.
Conclusion
SPAC is thought to be useful for detecting eyes at the risk of ACG by nonophthalmologists.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Erie JC, Hodge DO, Gray DT . The incidence of primary angle-closure glaucoma in Olmsted County, Minnesota. Arch Ophthalmol 1997; 115: 177–181.
Foster PJ, Baasanhu J, Alsbirk PH, Munkhbayar D, Uranchimeg D, Johnson GJ . Glaucoma in Mongolia. A population-based survey in Hovsgol province, northern Mongolia. Arch Ophthalmol 1996; 114: 1235–1241.
Foster PJ, Oen FT, Machin D, Ng TP, Devereux JG, Johnson GJ et al. The prevalence of glaucoma in Chinese residents of Singapore: a cross-sectional population survey of the Tanjong Pagar district. Arch Ophthalmol 2000; 118: 1105–1111.
Marchini G . Biometric data and pathogenesis of angle closure glaucoma. Acta Ophthalmol Scand Suppl 2002; 236: 13–14.
Quigley HA . Number of people with glaucoma worldwide. Br J Ophthalmol 1996; 80: 389–393.
Seah SK, Foster PJ, Chew PT, Jap A, Oen F, Fam HB et al. Incidence of acute primary angle-closure glaucoma in Singapore. An island-wide survey. Arch Ophthalmol 1997; 115: 1436–1440.
Foster PJ, Buhrmann R, Quigley HA, Johnson GJ . The definition and classification of glaucoma in prevalence surveys. Br J Ophthalmol 2002; 86: 238–242.
Kashiwagi K, Kashiwagi K, Toda Y, Osada K, Tsumura T, Tsukahara S . A newly developed peripheral anterior chamber depth analysis system—principle, accuracy, and reproducibility. Br J Ophthalmol 2004; 88: 1029–1034.
Kashiwagi K, Abe K, Tsukahara S . Quantitative evaluation of changes in anterior segment biometry by peripheral laser iridotomy using newly developed scanning peripheral anterior chamber depth analyzer. Br J Ophthalmol 2004; 88: 1035–1040.
Kondo T, Nakatsu A, Masami P . A method of image analysis for primary angle closure glaucoma. Ophthalmologica 1995; 209: 113–116.
Richards DW, Russell SR, Anderson DR . A method for improved biometry of the anterior chamber with a Scheimpflug technique. Invest Ophthalmol Vis Sci 1988; 29: 1826–1835.
Dragomirescu V, Hockwin O . Rotating slit image camera TOPCON SL 45. New developments for simultaneous image acquisition by photographic and CCD-assisted on-line documentation. Ophthalmic Res 1996; 28: 102–108.
Van Herick W, Shaffer RN, Schwartz A . Estimation of width of angle of anterior chamber. Incidence and significance of the narrow angle. Am J Ophthalmol 1969; 68: 626–629.
Jacobs IH . Anterior chamber depth measurement using the split-lamp microscope. Am J Ophthalmol 1979; 88: 236–238.
Lee DA, Brubaker RF, Ilstrup DM . Anterior chamber dimensions in patients with narrow angles and angle-closure glaucoma. Arch Ophthalmol 1984; 102: 46–50.
Osada K, Kashiwagi K, Tagawa K, Nakayama J, Tsukahara S . Reproducibility of a newly developed peripheral anterior chamber depth analysis system. Rinsho Ganka (Jpn J Clin Ophthalmol) 2004; 58: 715–718.
Congdon NG, Quigley HA, Hung PT, Wang TH, Ho TC . Screening techniques for angle-closure glaucoma in rural Taiwan. Acta Ophthalmol Scand 1996; 74: 113–119.
Devereux JG, Foster PJ, Baasanhu J, Uranchimeg D, Lee PS, Erdenbeleig T et al. Anterior chamber depth measurement as a screening tool for primary angle-closure glaucoma in an East Asian population. Arch Ophthalmol 2000; 118: 257–263.
Vargas E, Drance SM . Anterior chamber depth in angle-closure glaucoma. Clinical methods of depth determination in people with and without the disease. Arch Ophthalmol 1973; 90: 438–439.
Zhang SF . Measurement of the depth of the anterior chamber in primary glaucoma and its clinical application. Zhonghua Yan Ke Za Zhi 1983; 19: 12–16.
Alsbirk PH . Limbal and axial chamber depth variations. A population study in Eskimos. Acta Ophthalmol (Copenh) 1986; 64: 593–600.
Acknowledgements
We would like to express our sincerest appreciation to Messrs. Koji Tagawa and Junji Nakagawa for excellent technical assistance.
Author information
Authors and Affiliations
Corresponding author
Additional information
Propriety interest: The instrument is applied for Japanese Patent (Application No. 2003-111322).
Rights and permissions
About this article
Cite this article
Kashiwagi, K., Kashiwagi, F., Hiejima, Y. et al. Finding cases of angle-closure glaucoma in clinic setting using a newly developed instrument. Eye 20, 319–324 (2006). https://doi.org/10.1038/sj.eye.6701869
Received:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/sj.eye.6701869


