Abstract
We examined accuracy in prediction of a poor outcome (severe BPD i.e. ventilated at 28 days or death) using passive respiratory mechanics. Infants (BW >1000 g) who were ventilated on day 1 of life were examined serially. Length corrected compliance (Crs:ml/cmH2O/m) was compared in accuracy to other predictors: BW (g). Ventilation Index (VI) [FiO2 (%) x mean airway pressure (cmH2O)]. Out of 89 infants enrolled, 41 were still ventilated by day 6. On day 1, 75 infants were measured, 34 were measured on either days 5 or 6. Eleven infants had a poor outcome (1 death, 10 severe BPD).
Results: Of the predictors tested, Crs is the best by days 5-6.
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kirpalani, H., Wilkie, R., Schmidt, B. et al. PASSIVE COMPLIANCE IS A MORE ACCURATE PREDICTOR OF POOR OUTCOME THAN VENTILATOR REQUIREMENTS IN VENTILATED INFANTS. Pediatr Res 22, 229 (1987). https://doi.org/10.1203/00006450-198708000-00094
Issue date: