Abstract
Complete sampling of expired air is essential for accurate O2 consumption(CO2 production) [VO2(VCO2)] measurements with flow-through indirect calorimetry. In preterm infants complete sampling is critical, because only low sampling flows can be used. The accuracy of the various breath sampling systems at low flows and their patient compatibility is untested. We therefore measured 1) the accuracy of VO2(VCO2) measurements with a face mask, a head hood, and a canopy in vitro at low sampling flows; 2) the effect of breathing on measurements with the face mask; and 3) the effect of breath sampling systems on activity and body temperature of preterm infants. VO2(VCO2) were measured with a Deltatrac II™. In vitro we used a methanol miniburner incorporated into a doll, which could simulate low VO2(VCO2) and tidal breathing. In vivo we studied seven preterm infants <1500 g. With the face mask VO2(VCO2) measurements were accurate at a flow of 3 L/min (error-1 ± 0.8%), when tidal volume was <15 mL/breath and the distance between mask and manikin <1 cm. With hood and canopy VO2(VCO2) were underestimated at a flow of 3 L/min (error -13± 1% and -14 ± 5%), and results were markedly influenced by body position. For accurate measurements, the hood needed a flow of 4.5 L/min, the canopy 8.3 L/min. In vivo the face mask did not increase heart rate, respiration, activity, or rectal temperature, but hood and canopy increased rectal temperature by 0.3-0.4°C. For VO2(VCO2) measurements in infants <1500 g, a face mask should be used, which is accurate at low flows and does not change body temperature. Accuracy at low flows and patient compatibility of breath sampling systems should be evaluated and reported for VO2(VCO2) measurements in preterm infants.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
Abbreviations
- VO2:
-
oxygen consumption
- VCO2:
-
carbon dioxide production
References
Lister G, Hoffman JIE, Rudolph AM 1974 Oxygen uptake in infants and children: a simple method for measurement. Pediatrics 53: 656–662.
Shortland GJ, Fleming PJ, Walter JH 1992 Validation of a portable indirect calorimetry system for measurement of energy expenditure in sick preterm infants. Arch Dis Child 67: 1207–1211.
Schulze K, Kairam R, Stefanski M, Sciacca R, James LS 1981 Continuous measurement of minute ventilation and gaseous metabolism of newborn infants. J Appl Physiol 50: 1098–1103.
Stothers JK 1981 Head insulation and heat loss in the newborn. Arch Dis Cild 56: 530–534.
Takala J, Keinänen O, Väisänen P, Kari A 1989 Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device. Crit Care Med 17: 1041–1047.
Makita K, Nunn JF, Royston B 1990 Evaluation of metabolic measuring instruments for use in critically ill patients. Crit Care Med 18: 638–644.
Brueck K, Parmalee AH Jr, Brick M 1962 Neutral temperature ranges of thermal comfort in premature infants. Biol Neonate 4: 32–51.
Marks KH, Coen P, Kerrigan JR, Francalancia NA, Nardis EE, Snider MT 1987 The accuracy and precision of an open-circuit system to measure oxygen consumption and carbon dioxide production in neonates. Pediatr Res 21: 58–65.
Fixler DE, Carrell T, Browne R, Willis K, Miller WW 1974 Oxygen consumption in infants and children during cardiac catheterisation under different sedation regimens. Circulation 50: 788–794.
Handley JC, Spencer SA, Rakowski S, Rolfe P 1991 Critical appraisal and further development of the methodology for open circuit calorimetry in neonates. Early Hum Dev 26: 167–176.
Bell EF, Rios GR, Wilmoth PK 1986 Estimation of 24-hour energy expenditure from shorter measurement periods in premature infants. Pediatr Res 20: 646–649.
Yeh TF, Lilien LD, Leu ST, Pildes RS 1984 Increased O2-consumption and energy loss in premature infants following medical care procedures. Biol Neonate 46: 157–162.
Weinstein MR, Haugen K, Bauer JH, Hewitt J, Finan D 1987 Intravenous energy and amino acids in the preterm newborn infant: effects on metabolic rate and potential mechanisms of action. J Pediatr 111: 119–123.
Yeh TF, Admani M, Leu ST, Tan M, Pildes RS 1982 Simple daily technique to calculate total and interim changes of daily O2 consumption and CO2 production in premature infants. Crit Care Med 10: 534–538.
Moon JK, Jensen CL, Butte NF 1993 Fast-response whole body indirect calorimeters for infants. J Appl Physiol 74: 476–484.
Brooke OG 1985 Energy expenditure in the fetus and neonate: sources of variability. Acta Paediatr Scand S 319: 128–134.
Author information
Authors and Affiliations
Additional information
Supported by a grant from the Research Council of the Free University of Berlin.
Rights and permissions
About this article
Cite this article
Bauer, K., Pasel, K., Uhrig, C. et al. Comparison of Face Mask, Head Hood, and Canopy for Breath Sampling in Flow-Through Indirect Calorimetry to Measure Oxygen Consumption and Carbon Dioxide Production of Preterm Infants <1500 Grams. Pediatr Res 41, 139–144 (1997). https://doi.org/10.1203/00006450-199701000-00022
Received:
Accepted:
Issue date:
DOI: https://doi.org/10.1203/00006450-199701000-00022
This article is cited by
-
Assessment of radiant temperature in a closed incubator
European Journal of Applied Physiology (2012)