Table 1 Measurement settings

From: Application of a Full-Field macro-XRF imaging spectrometer to non-invasive investigation of elemental composition in three-dimensional artworks

Object

No. of frames

Acquisition time for one frame [min]

Measured area [cm2]

Fragment of ornament from a church altar

4

20

20 × 18

Inkwell with lid

4a

32

8 × 6

  1. aEach one of the four sides of the object was measured in a single frame.