Table 4 Effect of domestic filters on disinfection by-products (DBPs) concentrations in tap water.

From: Insights to estimate exposure to regulated and non-regulated disinfection by-products in drinking water

 

N ≥ LOQ

% ≥ LOQ

Min

Perc25

Perc50

Perc75

Max

Mean

SD

Average % Change

Total haloacetic acids (HAAs)

 Before AC filter

6

100

2.7

14

16

32

38

21

14

−52

 After AC filter

6

100

1.5

5.2

11

15

16

9.9

6.3

 Before RO filter

4

80

<LOQ

19

20

20

21

19

2.4

−100

 After RO filter

0

0

<LOQ

<LOQ

<LOQ

<LOQ

<LOQ

<LOQ

Total trihalomethanes (THMs)

 Before AC filter

6

100

34

44

51

56

82

53

16

−80

 After AC filter

6

100

0.1

6.1

11

16

20

11

7.4

 Before RO filter

5

100

28

35

39

46

48

39

8.0

−99

 After RO filter

3

60

<LOQ

0.1

0.1

0.8

1.5

0.6

0.8

Total haloacetonitriles (HANs)

 Before AC filter

6

100

3.2

3.3

3.5

3.7

4.7

3.6

0.6

−75

 After AC filter

5

83

<LOQ

0.4

0.7

1.2

1.8

0.9

0.6

 Before RO filter

5

100

2.2

2.7

3.9

4.0

4.2

3.4

0.9

−100

 After RO filter

0

0

<LOQ

<LOQ

<LOQ

<LOQ

<LOQ

<LOQ

1,1,1-trichloropropanone (TCP)

 Before AC filter

3

50

<0.01

0.8

1.1

1.1

1.2

0.9

0.4

−63

 After AC filter

1

17

<0.01

0.3

0.3

0.3

0.3

0.3

0

 Before RO filter

1

17

<0.01

1.3

1.3

1.3

1.3

1.3

0

−100

 After RO filter

0

0

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01

Chlorite

 Before AC filter

5

83

<10

16.8

17.2

119

142

61.2

63.8

−60

 After AC filter

3

50

<10

17.0

17.0

28.4

39.7

24.5

13.1

 Before RO filter

2

40

<10

22.6

22.6

22.6

22.6

22.6

0

−100

 After RO filter

0

0

<10

<10

<10

<10

<10

<10

Chlorate

 Before AC filter

6

100

153

193

219

314

367

248

86.3

−27

 After AC filter

6

100

116

144

178

185

296

181

62.9

 Before RO filter

4

80

<10.0

167

183

232

341

217

84.4

−98

 After RO filter

5

100

18.2

28.1

34.2

35.5

44.4

32.1

9.70

  1. Number of samples (N, %) with DBPs above the limit of quantification (LOQ) and concentrations (µg/L) in tap water before and after activated carbon (AC, N = 6) and reverse osmosis (RO, N = 5) filters.