Table 2 Measured and theoretical conversion efficiency when V1/V212) = 0 V/12 V (0°/180°) with T = 6.4 μs

From: Independent control of harmonic amplitudes and phases via a time-domain digital coding metasurface

Harmonic order

Measured V1/V2 = 0 V/12 V

Theoretical φ1/φ2 = 0°/180°

Error

−4th

0.08%

0%

0.08%

−3rd

3.14%

4.50%

−1.36%

−2nd

0.08%

0%

0.08%

−1st

34.93%

40.53%

−5.60%

0th

3.49%

0%

3.49%

+1st

35.87%

40.53%

−4.66%

+2nd

0.09%

0%

0.09%

+3rd

3.31%

4.50%

−1.19%

+4th

0.10%

0%

0.10%